IntelliChlor Electronic Chlorine Generator Installation and User’s Guide
Calculating the Saturation Index
The saturation index is a formula that relates pH, calcium and alkalinity in the pool water. A well balanced
pool water will have a formula result range between -0.3 and 0.3 Outside this range, the pool water is out of
balance, potentially damaging pool equipment or scaling the IECG.
The equation to calculate Si is:
Cyanuric acid in the form of cyanurate ions contribute to alkalinity. Thus, a correction must be made to total
alkalinity. We subtract 1/3 of the cyanuric acid level from the reading obtained in the total alkalinity test.
Total Alkalinity - 1/3 Cyanuric Acid = Corrected Alkalinity
This correction can be considerable in established pools with high cyanuric acid levels; for example, at 240
ppm cyanuric acid, the correction amounts to 80 ppm (240 ÷ 3 = 80).
SI = pH + CHF + AF + TF + TDSF
Saturation
Index
pH as
tested
Calcium
Hardness
Factor
Alkalinity
Factor
Tempera-
ture
Factor
TDS
Factor
Langelier Saturation Index Factors
TDS
Factor
<1000
12.10
1000
12.19
2000
12.29
3000
12.35
4000
12.41
5000
12.44
TDS Factor
(Factors shown below are based on the actual measured value for the particular parameter)
Summary of Contents for IntelliChlor CIC60P
Page 22: ...16 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Page 26: ...20 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Page 30: ...24 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...
Page 34: ...28 IntelliChlor Electronic Chlorine Generator Installation and User s Guide Blank Page ...