INSTALLATION INSTRUCTIONS
25
Natural Gas
Pipe Sizing Chart
Length of
Pipe In Feet
Size of Schd. 40 Black Iron Pipe in Inches
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
10
108
230
387
793
1237
2259
20
75
160
280
569
877
1610
30
61
129
224
471
719
1335
40
52
110
196
401
635
1143
50
46
98
177
364
560
1041
60
42
89
159
336
513
957
70
38
82
149
317
476
896
80
36
76
140
239
443
840
90
33
71
133
275
420
793
100
32
68
126
266
411
775
125
28
60
117
243
369
700
Natural Gas flow is given in thousands of BTU/hr. - One cubic foot of natural gas = 1000 BTU
Nominal pressure at the burner for Natural Gas is 3.5" of water column. (Typical machine supply 5"-7")
Pipe length must include additional length for all fittings. Add approximately 5 feet of pipe per fitting
Natural Gas Example: A machine with a burner that requires 440,000 BTU would need a 1 -1/4" pipe for
a 20' long run.
Liquid Propane
Gas Pipe Sizing Chart
Length of
Pipe in Feet
Size of Schd. 40 Black Iron Pipe in Inches
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
10
275
567
1071
2205
3307
6221
20
189
393
732
1496
2299
4331
30
152
315
590
1212
1858
3465
40
129
267
504
1039
1559
2992
50
114
237
448
913
1417
2646
60
103
217
409
834
1275
2394
80
89
185
346
724
1086
2047
100
78
162
307
630
976
1811
125
69
146
275
567
866
1606
150
63
132
252
511
787
1496
LP Gas flow is given in thousands of BTU/hr. - One cubic foot of LP gas - 2516 BTU
This chart refers to low pressure LP, after regulation Standard nominal pressure at the burner for
Liquid Propane Gas is 11" of water column.
Pipe length must include additional length for all fittings. Add approximately 5 feet of pipe per fitting
LP Example: A machine with a burner that requires 440,000 BTU would need a 1" pipe for a 20' long run.
Summary of Contents for PCI 18
Page 8: ...GENERAL INFORMATION 5 ...
Page 9: ...GENERALInformation 6 ING ...
Page 10: ...GENERALInformation 7 ...
Page 11: ...GENERALInformation 8 ...
Page 25: ...INSTALLATION INSTRUCTIONS 22 3 6 Piping Diagram ...
Page 33: ...INSTALLATION INSTRUCTIONS 29 Venting Pictures Illustrations ...
Page 63: ...INSTALLATION INSTRUCTIONS 59 6 8 Wiring diagrams ...