T I L L E R M O D U L E
P E N N Y & G I L E S D R I V E S T E C H N O L G Y
Chapter 3:
40
Solo Technical Manual SK74484/1
Fig 4 - Connector Positions
4.2
Tiller Module Version - TruCharge Indicator and
Diagnostics
For this version the following connections should be made.
CON 2 Pin
Connect to
Function
1
Switched 24V(36V)
Switched 24V(36V)
3
Solo P2-12
Status Indicator signal
7
0V or Solo P2-4
0V
For connection to the ESD pin, see section 5.2.
4.3
Tiller Module Version - Momentary Switch Inputs
The switches may be in the form of a membrane or conductive
rubber keypad or individual pushbuttons. The input is activated by
being connected to 0V (normally CON1 pin 1). Although CON1
pin 1 is 0V, it is only a low current supply and must not be used
for any purpose other than tiller module input connections.