Hot and Cold water supply requirements
Electrical requirements
¾” supply lines with on/off valves NPT male threads. We recommend a ¾” ball valve with ¾”
NPT male ports. (Valves supplied by others.) See figure 14-15
For optimum performance, dynamic pressures should be nominally equal between hot and
cold supplies.
Maximum static supply pressure: 145 PSI.
Maximum dynamic/maintained supply pressure: 81 PSI.
Maximum supply Hot water temperature: Consult local requirements for maximum allowed
supply temperatures. (Not recommended over 120°F).
Figure 14-15
The Dream Spa is rated 10.5 Amps at 120 Volts AC.
A 15 amp GFCI circuit is required.
The Load Center is located on the back inside wall of the Dream tub. It is supplied with a 3
foot electrical cord for a 120 V outlet. Please contact Penner Manufacturing, INC. for
further options. Best location for power supply is through the rear skirt access door. Small
cutouts through tub skirt as needed can allow for various electrical supply options. See
figure 14-15.
It is recommended that the power wires be installed by an electrician. Then
connect the Dream spa electrical cord.