background image

Fusion Spa

minipool

Installation manual 

Содержание Fusion Spa 230

Страница 1: ...Fusion Spa minipool Installation manual...

Страница 2: ...ead this manual carefully before installing it The Treesse team is always available for any information or request for assistance that may be required during installation GRUPPO TRE S s p a Telephone...

Страница 3: ...10 3 CONNECTIONS REQUIRED__________________________________________________________ 11 4 PLUMBING CONNECTIONS_________________________________________________________ 13 CHARACTERISTICS OF THE WATER S...

Страница 4: ...odifications that do not follow the information provided in this manual can cause damages injuries or fatal accidents and null and void the warranty During the installation of the minipool do not plac...

Страница 5: ...de in compliance with current regulations in force in the country of installation A drain a gate valve to shut off the supply water and drain valves have been installed to empty the bathtub at the end...

Страница 6: ...personal protective equipment e g gloves safety shoes etc and taking all the necessary safety precau tions for those involved and to not damage the minipool During transport lift the minipool by holdi...

Страница 7: ...he height of the minipool s feet to compensate up to a maximum of 1 cm For a recessed installation lower the minipool into the prepared space If it was not possible to provide a technical inspection p...

Страница 8: ...water C drain More information WHAT IS THE SAND FILTER The sand filter is an effective minipool filter connected to the recirculation pump s feed line It consists of a large container that is two thir...

Страница 9: ...3B 3A 3A 2 3 5 4 6 0 5 1mm 7 10 8 10A 10A 11A 10B 11B 11C 11 12 13 0 5 1mm B 9 Caution Do not inhale Carefully clean and verify that the gaskets are still in place INTERIOR top view Caution Make sure...

Страница 10: ...it is recommended to carefully read the safety warnings at the beginning of this manual and to always operate in perfect physical and mental condition The installer qualified and authorised by the Man...

Страница 11: ...al and plumbing connection to an exchanger optional if present see following page The following pages will provide detailed explanations of how to perform these preparations EXAMPLES OF OUTDOOR INDOOR...

Страница 12: ...rical connections Drain Water supply Technical inspection port IN incoming hot domestic water OUT outgoing cold water 230V C S P in out PR TC EV BS P2 BL 1 BL2 HTR Cromo 230V EVc EVs EVclv 230V heater...

Страница 13: ...Ideal values of alkalinity range between 80 mg L and 125 mg L 8 F 12 5 F Values outside of this range can more easily cause variations of the pH Instead alkalinity within the range noted makes it pos...

Страница 14: ...male hose provided If the minipool is installed outdoors provide an adequate thermal insulation of the pipes It is the plumber s responsibility to choose the type of materials to be used Connect the d...

Страница 15: ...th a contact gap of at least 3 mm and a breaking capacity equal to 60A or in any case adequate for the absorption of the bathtub Controlled by a differential switch no larger than 30mA The control uni...

Страница 16: ...ed and properly connected to the pipes The water connections have been made properly in accordance with local and national codes and that they can guarantee a perfect seal verification to be carried o...

Страница 17: ...bit of water and a mild detergent Do not use cloths or cleaners that are abrasive aggressive or that contain solvents because they could irreparably damage the surface of the minipool Do not start an...

Страница 18: ...ng sanitising ozone active KEY COMBINATIONS FILL bathtub EMPTY bathtub change mode from ACTIVE to STANDBY key entry exit from sleep mode WHITE sleep mode NOT active BLUE sleep mode active whirlpool ac...

Страница 19: ...n to stop the function The first time it is recommended to leave the whirlpool in operation for at least 2 3 minutes to expel the air that may be present in the plumbing system CHROMATHERAPY Chromathe...

Страница 20: ...hing the LED flashes the key for about 3 seconds during backwashing the letters FLT appear on the display Backwashing disables The recirculation pump The heater The ozonator A backwash cycle can be in...

Страница 21: ...lay even if it is not visible it is still active then press the key emptying in progress is indicated by the flashing blue key The emptying of the minipool can be activated at any time Emptying lasts...

Страница 22: ...disconnect the power supply to the bathtub and switch it on again after 30 seconds If the problem persists verify that the connection with the control unit is correct and has not been tampered with Ot...

Страница 23: ...LL alternating with the temperature the functions remain enabled the system will start filling the bathtub to restore the level see the section on filling the minipool on page 17 The notification is...

Страница 24: ...After the first cleaning of the bottom the problem should no longer exist Cleaning the bottom with a minipool cleaner Make sure you have used sand with granularity from 0 5 to 1 mm suitable for this...

Страница 25: ...25 Fusion Spa minipool EN Mount the laminate resin panels as shown in the figure below Decorative panels 1 2 1 1 3 3 INDOOR INSTALLATION OUTDOOR INSTALLATION...

Страница 26: ...ty Under these conditions or when not used advise the owner to use a fixed or mobile cover to protect the minipool we recommend the optional Treesse covers In addition to preserving the surfaces the c...

Страница 27: ...e small differences between this manual and the product you have received we apologise in advance for any inconvenience The total or partial reproduction of this manual without the Manufacturer s cons...

Страница 28: ...sion Spa installation Edition 03 2018 www gruppotreesse it GRUPPO TRE S s p a 01036 Nepi VT Italy S S Cassia km 36 400 Settevene industrial area tel 39 0761 527242 fax 39 0761 527223 info gruppotres i...

Отзывы: