P70, P72, P170 Series Controls for High Pressure Applications Installation Instructions

    

 

Table 2: Standard P70, P72, and P170 Control Models for High Pressure Applications 

Model 
Number 

Switch Action 

Range 
Psig (kPa) 

Differential 
Psi (kPa) 

Pressure 
Connection 

Maximum Working 
Pressure (MWP) 
Psi (kPa) 

Condenser Fan Cycling Control Models (for Noncorrosive Refrigerants) 

P70AA-118 

SPST 
Open-Low 

100 to 400 
psig 
(690 to 2758) 

Minimum 35 
(241) 
Maximum 200 
(1379) 

36 in. Capillary with 
1/4 in. Flare Nut 

475 

(3275) 

P72AA-27 

DPST 
Open-Low 

100 to 400 
psig 
(690 to 2758) 

Minimum 35 
(241) 
Maximum 200 
(1379) 

P170AA-118 

SPST 
Open-Low 

1/4 in. Male 
Flare Connector 

All-Range Control Models (for Noncorrosive Refrigerants) 

P70CA-2* 

SPST 
Open-High 

50 to 500 
(345 to 3448) 

Minimum 60 
(414) 
Maximum 150 
(1034) 

1/4 in. Male 
Flare Connector 

525 

(3620) 

P70CA-3* 

36 in. Capillary with 
1/4 in. Flare Nut 

P70DA-1* 

Manual Reset 
Lockout 

P70KA-1* 

4-Wire, 2-Circuit 
Line-M1 Close-High 
Line-M2 Open-High 

P72CA-2* 

DPST 
Open-High 

Minimum 60 
(414) 
Maximum 150 
(1034) 

P72DA-1* 

manual Reset 
Lockout 

P170CA-3* 

SPST 
Open-High 

Minimum 60 
(414) 
Maximum 150 
(1034) 

1/4 in. Male 
Flare Connector 

P170DA-1* 

Manual Reset 
Lockout 

P170KA-1* 

4-Wire, 2-Circuit 
Line-M1 Close-High 
Line-M2 Open-High 

Ammonia-Compatible Models 

P70AA-119 

SPST 
Open-Low 

50 to 300 

Minimum 20 
(138) 
Maximum 120 
(827) 

1/4 in. SS 
Female NPT 

525 

(3620) 

P70CA-5* 

SPST 
Open-High 

50 to 500 
(345 to 3448) 

Minimum 60 
(414) 
Maximum 150 
(1034) 

P70DA-2* 

Manual Reset 
Lockout 

Continued on next page . . .  

 

Summary of Contents for P170A

Page 1: ...models with Single Pole Double Throw SPDT or 4 Wire 2 Circuit switch action allow users to install alarm devices or other control circuits P72 Series models have a Double Pole Single Throw DPST switch...

Page 2: ...mounting screws supplied with the Universal Mounting Bracket to avoid damaging internal components Be careful not to distort or bend the control case when mounting the control to an uneven surface Us...

Page 3: ...n wiring the control WARNING Risk of Electrical Shock Disconnect each of multiple power supplies before making electrical connections More than one disconnect may be required to completely de energize...

Page 4: ...ut Automatic Reset High pressure Cutout controls with automatic reset have a scaleplate that displays the Cut In and Cutout setpoints See the visible scale on the control Turn the range screw to adjus...

Page 5: ...operation Manual Reset Operation Pressure controls with the Manual Reset option lock out when they reach Cutout pressure and must be manually reset by the user to restart the controlled equipment The...

Page 6: ...or All Range Control Models for Noncorrosive Refrigerants P70CA 2 SPST Open High 50 to 500 345 to 3448 Minimum 60 414 Maximum 150 1034 1 4 in Male Flare Connector 525 3620 P70CA 3 36 in Capillary with...

Page 7: ...or models not included in this table contact the Refrigeration Application Engineering Group at 1 800 275 5676 for details and availability Note See Dimensions and Technical Specifications for additio...

Page 8: ...e Amperes 16 0 9 2 8 0 7 2 6 0 6 0 6 0 6 0 Pilot Duty for both sets of contacts 125 VA at 24 to 600 VAC 57 5 VA at 120 to 300 VDC Not for compressor motor loads Table 6 DPST Electrical Ratings P72A B...

Page 9: ...ntrols 60 lb 27 2 kg Compliance For information on specific models contact the Refrigeration Application Engineering Group at 1 800 275 5676 Accessories 271 51 Universal Mounting Bracket supplied with...

Reviews: