50
Cyclone MAX User Manual
CYCLONE MAX
out the pre-configured Cyclone operations.
Comments are allowed in the script files. All lines beginning with the semi-
colon character ; are treated as comments by the application.
6.1.3.1
Setup Commands
SETLOCALIP=ipaddress
Only needed if the host PC has more than one network card. “ipaddress”
indicates the IP address of the network card that should be used during
communications. If this command is used, it should be the first command in
the script file. “ipaddress” should be in the format of xxx.xxx.xxx.xxx, where
xxx=0...255.
OPENTYPE=x
Specifies whether the Cyclone MAX will be identified by IP address or by
device name. Both of these Cyclone parameters are reconfigurable by the
user.
and need to be set up prior to using CYCLONE_LAUNCH. Please see
Section 8.6 - Cyclone IP Setup Utility User Interface (ConfigureIP)
for more information on how to configure the Cyclone IP number and the
Cyclone Device Name. Note that this choice of Cyclone identification is not
affected by how the Cyclone is connected to the PC (USB, Ethernet, or Serial).
The value of x may be:
IP- Cyclone units will be identified by their IP addresses
NAME- Cyclone units will be identified by their device names
PORT=y
Specifies the port that should be used for contacting the Cyclone MAX.
The value of y may be:
USB
ETHERNET
SERIAL