If products cannot be finished immediately, cover with clear plastic to protect from dirt, damage 
and moisture. Remove any construction residue before finishing. Sand all wood surfaces lightly 
with 180 grit or finer sandpaper. DO NOT use steel wool. BE CAREFUL NOT TO SCRATCH 
THE GLASS. Remove sanding dust.

Pella products must be finished per the below instructions; failure to follow these instructions voids 
the Limited Warranty.
• On casement and awnings, it is optional to paint, stain or finish the vertical and horizontal sash  
  edges.
• On single-hung and double-hung, do not paint, stain or finish the vertical sash edges, any finish   
  on the vertical sash edges may cause the sash to stick; it is optional to paint, stain or finish the 
  horizontal sash edges.
• On patio doors, it is optional to paint, stain or finish the vertical and horizontal panel edges.

Note: To maintain proper performance do not paint, finish or remove the weather-stripping, 
mohair dust pads, gaskets or vinyl parts. Air and water leakage will result if these parts are 
removed. After finishing, allow venting windows and doors to dry completely before closing 
them.

Pella Corporation is not responsible for interior paint and stain finish imperfections for any 
product that is not factory-applied by Pella Corporation. Use of inappropriate finishes, solvents, 
brickwash, or cleaning chemicals will cause adverse reactions with window and door materials and 
voids the 
Limited Warranty.

For additional information on finishing see the Pella Owner's Manual or go to www.pella.com.

IMPORTANT NOTICE 

Because all construction must anticipate some water infiltration, it is important that the wall 
system be designed and constructed to properly manage moisture. Pella Corporation is not 
responsible for claims or damages caused by anticipated and unanticipated water infiltration; 
deficiencies in building design, construction and maintenance; failure to install Pella

®

 products in 

accordance with Pella installation instructions; or the use of Pella products in wall systems which 
do not allow for proper management of moisture within the wall systems. The determination of the 
suitability of flashing and sealing systems are the responsibility of the Buyer or User, the architect, 
contractor, installer, or other construction professional and are not the responsibility of Pella.

Pella products should not be used in barrier wall systems which do not allow for proper 
management of moisture within the wall systems, such as barrier Exterior Insulation and Finish 
Systems, (EIFS) (also known as synthetic stucco) or other non-water managed systems. Except 
in the states of California, New Mexico, Arizona, Nevada, Utah, and Colorado, Pella makes no 
warranty of any kind on and assumes no responsibility for Pella windows and doors installed in 
barrier wall systems. In the states listed above, the installation of Pella Products in barrier wall or 
similar systems must be in accordance with Pella’s installation instructions.

Product modifications that are not approved by Pella Corporation will void the Limited Warranty.

EXTERIOR FINISH

The exterior frame and sash are protected by aluminum cladding with our tough EnduraClad

®

 

or EnduraClad Plus baked-on factory finish that needs no painting. Clean this surface with mild 
soap and water. Stubborn stains and deposits may be removed with mineral spirits. DO NOT use 
abrasives. DO NOT scrape or use tools that might damage the surface.

Use of inappropriate finishes, solvents, brickwash or cleaning chemicals will cause adverse reactions 
with window and door materials and voids the Limited Warranty.

CARE AND MAINTENANCE

Care and maintenance information is available in the Pella Owner’s Manual. You can obtain an 
owner’s manual by contacting your local Pella retailer. This information is also available on www.
pella.com.

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

ALL

Summary of Contents for 81470102

Page 1: ...ion in a wall system designed to manage water These instructions are not to be used with any other construction method Installation instructions for use with other construction methods multiple units...

Page 2: ...knife Drill with a 2 Phillips at least 4 long and 3 square drive bit provided in cable clamp kit 1 2 open end wrench 3 16 wrench or socket Sealant Gun Installation will require two or more persons for...

Page 3: ...k and rough opening Apply sealant at each joint between the brick blocking and rough opening and cover the joints with flashing tape H Apply sill flashing tape 1 Wood wall construction only Cut a piec...

Page 4: ...tape 2 Cut a piece of flashing tape 12 longer than the opening width Apply at the bottom overlapping tape 1 by at least 1 DO NOT allow the tape to extend past the interior face of the opening Note The...

Page 5: ...Check window for squareness by making sure diagonal measurement for corner to corner is within 1 8 in both directions Insert a 10 x 3 flat head wood screw into each pre drilled hole in the jamb boards...

Page 6: ...etween the rafter tails directly above the cable holes in the bay bow head board B Remove the cable from the bay bow unit Measure the distance from the bottom of the cable clamp to the bottom of the h...

Page 7: ...put on the seat board knee braces must be used in addition to the cables HEAD BOARD SEAT BOARD 18 PROJECTION MAXIMUM DASHED LINES INDICATE POSSIBLE CONSTRUCTION FOR GABLE ROOF MINIMUM 10 1 2 HEADER MO...

Page 8: ...space between the window and the rough opening and apply a 1 deep bead of foam This will allow room for expansion of the foam and will minimize squeeze out If using foam other than Great Stuff Window...

Page 9: ...Foam BRICK FRAMED REPLACEMENT 3 8 Clearance Backer Rod and Sealant typical Insulating Foam BRICK SMALL BLOCK REPLACEMENT Air Gap Block 1 x 2 Sheet Rock Lathe Plaster Insulating Foam 3 8 Clearance Bac...

Page 10: ...ween the frame expander and the under side of the seat board F Shape tool and clean excess sealant When finished the sealant should be the shape of an hourglass Note This method creates a more flexibl...

Page 11: ...cess sealant When finished the sealant should be the shape of an hourglass Note Backer rod adds shape and depth for the sealant line This method creates a more flexible sealant line capable of expandi...

Page 12: ...construction and maintenance failure to install Pella products in accordance with Pella installation instructions or the use of Pella products in wall systems which do not allow for proper management...

Reviews: