General Information
Section 3
Installation
3.1 Installing UV System
The disinfection system is designed to be mounted either horizontally or vertically at the point-of-use or point-of-entry
depending on the specific flow rate of the unit.
Item
Description
Function
1
Sample valve
Allows for sampling of raw water.
2
Shut-off valve
Required to allow maintenance of pre-treatment equipment.
3
Pre-treatment
Refer to
Section 1.3
.
Note:
A 5 micron (nominal) sediment filter must be installed before the UV system and after any water softening
equipment.
4
Bypass shut-off valve
Bypass line and valve are optional. Intended to provide emergency water supply in the event that the
UV system is unavailable.
5
Shut-off valve
Required to allow maintenance of UV system.
6
Sample valve
Allows for sampling of water entering UV chamber; necessary in order to confirm water being treated
is of adequate quality.
7
UV chamber
Provides disinfection of the water. Must install Plus model chambers vertically.
8
Temperature management valve
Drains water from the chamber that’s been warmed by the lamp during periods of no flow.
9
Flow Restrictor
Restricts water from flowing over the maximum NSF certified flow rate ensuring an adequate UV
dose is maintained.
10
Sample valve
Allows for sampling of water immediately following UV treatment; necessary in order to confirm
proper operation of UV system.
11
Solenoid valve
Optional piece of equipment supplied by VIQUA for PUV-8 and PUV-16 models. Must be used with a
junction box. Allows water supply to be shut-off when proper purification cannot be assured.
Note:
If the ground from your electrical panel is tied to your copper water lines, and you are using a solenoid valve,
installation of an approved ground strap is required. This ground strap will maintain continuity between the lines that
have been cut to install the solenoid. Check your local electrical code for the correct clamp and cable size.
12
Shut-off valve
Required to allow maintenance of UV system.
13
Junction box
An optional piece of equipment for PUV-8 and PUV-16 models. Powers solenoid valves, remote
alarms and auto-dialers.
14
Controller
Powers and controls the UV lamp and other devices. Provides human interface, displaying
information and allowing control inputs (such as muting the audible alarm).
15
Power Supply
Provides power to the controller. For safety reasons the outlet must be protected by a Ground Fault
Circuit Interrupter (GFCI).
Note:
to protect the controller, a UL1449 certified (or equivalent) transient voltage surge suppressor is
required.
Model
L
Ø
A (max.)
B
C
D (max.)
PUV-8
20.5" (52 cm)
4" (10 cm)
72" (183 cm)
8.5" (22 cm)
6" (15 cm)
54" (137 cm)
PUV-16
30" (76 cm)
4" (10 cm)
72" (183 cm)
8.5" (22 cm)
6" (15 cm)
54" (137 cm)
C A U T I O N
Electronic controller must be connected to a Ground Fault Protected Circuit (GFCI) receptacle. Ensure green ground wire ring terminal is securely
fastened to ground stud on UV chamber.
Mantenimiento
3.2 Procedimiento de desinfección
La desinfección UV es un proceso de desinfección física que no añade sustancias químicas potencialmente dañinas al
agua. Dado que la tecnología UV no proporciona residuos de desinfección, es imprescindible que se desinfecte
químicamente todo el sistema de distribución situado después de UV para asegurar que el sistema de tuberías esté libre de
cualquier contaminante bacteriológico. Se debe llevar a cabo el proceso de desinfección inmediatamente después de
instalar la unidad de UV. Asimismo, se debe repetir un poco después cuando la UV deje de funcionar por el servicio,
cuando no haya energía o cuando no esté operativa por algún motivo. El procedimiento para sanear el sistema de tuberías
se realiza rápidamente del siguiente modo:
1
•
Asegúrese de que el controlador
esté conectado durante todo el
proceso de desinfección.
2
1
2
1
1
1
•
Corte el suministro de agua.
•
Abra un grupo aguas abajo para
liberar la presión de la línea.
3
•
Pulse el botón de presión para
liberar la presión de los cartuchos.
4
•
Quite la carcasa del filtro con una
llave para filtros de agua.
5
Solución de lejía de
uso doméstico al 5,25%
LEJÍA
x2
2
1
•
Quite los cartuchos del filtro y
vierta dos vasos de solución de
lejía de uso doméstico en las
carcasas del filtro.
Nota:
NO utilice peróxido de
hidrógeno.
6
•
Conecte solo la carcasa del filtro
a la unidad.
7
•
Abra los grifos y encienda el
suministro de agua.
•
Permita que el agua rellene la
cámara.
8
0
30
15
45
30 min
•
Encienda el suministro de agua
fría seguido de agua caliente
(si está disponible) hasta que
huela la lejía.
•
Cierre todos los grifos y permita
que la lejía se deposite en las
líneas de agua durante 30 minutos.
9
•
Con todos los grifos cerrados,
quite la carcasa del filtro con una
llave para filtros de agua.
10
10
1
2
•
Vuelva a instalar los cartuchos en
las carcasas del filtro y conéctelos
a la unidad.
•
Limpie todas las salidas de agua
hasta que no huela a lejía
(5 minutos por lo menos).
11
•
Pulse el botón de presión para
purgar el aire y para finalizar el
procedimiento de desinfección.
42
7