Pelican PUV-16 Owner'S Manual Download Page 1

powered by

 425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1

t. (+1) 519.763.1032 • tf. (+1) 800.265.7246 (US and Canada only)

t. (+31) 73 747 0144 (Europe only) • f. (+1) 519.763.5069

e-mail: [email protected] 

www.viqua.com

425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1

t. (+1) 519.763.1032 • tf. (+1) 800.265.7246 (US et Canada seulement)

t. (+31) 73 747 0144 (Europe seulement) • f. (+1) 519.763.5069

Courriel : [email protected]

www.viqua.com

425 Clair Rd. W, Guelph, Ontario, Canadá N1L 1R1

t. (+1) 519.763.1032 • tf. (+1) 800.265.7246 (solo EE. UU. y Canadá)

t. (+31) 73 747 0144 (solo Europa) • f. (+1) 519.763.5069

correo electrónico: [email protected]

www.viqua.com

powered by

425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1
t. (+1) 519.763.1032 • tf. (+1) 800.265.7246 (US and Canada only)
t. (+31) 73 747 0144 (Europe only) • f. (+1) 519.763.5069
e-mail: [email protected]

www.viqua.com

NSF Standard 55 Class B 

Certified Models:

PUV-8, PUV-16

Owner’s Manual

powered by

System Tested and Certified by
NSF International against CSA
B483.1 and NSF/ANSI 55 for
Disinfection Performance, Class B

520240-R_RevM

Garantía del fabricante

Las garantías limitadas que se describen anteriormente solo se aplican a la gama de productos de VIQUA. En estas 

garantías limitadas se describe el único recurso para todas las reclamaciones basadas en un fallo o defecto de cualquiera 

de estos productos, ya sea que la reclamación se base en contrato, agravio (incluida la negligencia), responsabilidad 

estricta u otro. Estas garantías reemplazan a todas las demás garantías escritas, orales, implícitas o reglamentarias. 

No corresponde, sin limitación, ninguna garantía de comerciabilidad o aptitud para un propósito particular a ninguno de 

estos productos.
VIQUA no asume ninguna responsabilidad por lesiones o daños a la propiedad causados por el uso o el mal uso de 

cualquiera de los productos mencionados anteriormente. VIQUA no será de ningún modo responsable de los daños 

especiales, incidentales, indirectos o consecuentes. La responsabilidad de VIQUA se limitará, en todos los casos, a la 

reparación o reposición del producto o la pieza defectuosa y esta responsabilidad finalizará al finalizar el período de 

garantía aplicable.

Summary of Contents for PUV-16

Page 1: ...Disinfection Performance Class B 520240 R_RevM Garant a del fabricante Las garant as limitadas que se describen anteriormente solo se aplican a la gama de productos de VIQUA En estas garant as limita...

Page 2: ...tacto con nuestro equipo de soporte t cnico en el 1 800 265 7246 o por correo electr nico en la direcci n technicalsupport viqua com Nuestro t cnicos completamente formados le ayudar n a resolver el p...

Page 3: ...OT modify the plug provided with this system if it does not fit in the outlet have a proper outlet installed by a qualified electrician DO NOT use any type of adapter with this system GROUND FAULT CIR...

Page 4: ...ystem from the extension cord Never yank cord to pull plug from outlet Always grasp the plug and pull to disconnect If the supply cord is damaged it must be replaced by a special cord or assembly avai...

Page 5: ...capa debe retirarse porque reduce la cantidad de luz UV que llega al agua reduciendo de este modo el rendimiento de la desinfecci n Si la vaina tubular no puede limpiarse deber reemplazarse por otra R...

Page 6: ...stema de desinfecci n para asegurar que los indicadores de corriente est n encendidos y que no hay ninguna alarma Reemplace la l mpara UV anualmente o cada dos a os si se trata de un uso casero tempor...

Page 7: ...ust be protected by a Ground Fault Circuit Interrupter GFCI Note to protect the controller a UL1449 certified or equivalent transient voltage surge suppressor is required Model L A max B C D max PUV 8...

Page 8: ...rmaci n sobre la instalaci n o reposici n de la vaina tubular de cuarzo 5 Inserte la ficha de referencia entre el controlador y la abrazadera de montaje Nota La salida debe estar protegida mediante un...

Page 9: ...la instalaci n horizontal de la c mara la lumbrera de salida debe orientarse hacia arriba para garantizar la plena purga de todo el aire contenido en la c mara Nota La instalaci n ideal es la vertical...

Page 10: ...stema UV no est disponible 5 V lvula de corte Se requiere para permitir realizar las tareas de mantenimiento del sistema UV 6 V lvula de muestra Permite tomar muestras del agua que entra en la c mara...

Page 11: ...g screw 7 Align connection pins with the lamp connector by rotating the ring clamp Push the lamp connector down onto the lamp pins and the ring clamp pins until an audible click is heard Note Ensure t...

Page 12: ...amp Refer to Section 4 1 Note Ensure quartz sleeve is properly centered into the chamber Informaci n general Secci n 2 Informaci n general Figura 1 Componentes del sistema Elemento Descripci n N pieza...

Page 13: ...ueden derivar en exposiciones a radiaciones peligrosas de luz ultravioleta La radiaci n UV incluso en peque as dosis puede da ar los ojos y la piel Los cambios o modificaciones realizadas a este siste...

Page 14: ...indica que se requiere el uso de botas de seguridad Este s mbolo indica que el sistema est bajo presi n Este s mbolo indica que el operador debe leer toda la documentaci n disponible para realizar los...

Page 15: ...un extenso desarrollo que ha resultado en una plataforma de desinfecci n altamente eficaz con un rendimiento de UV extremadamente estable a lo largo de todo su ciclo de vida de 9000 horas Su xito ha...

Page 16: ...ate of purchase During this time VIQUA will repair or replace at its option any defective VIQUA UV chamber Please return the defective part to your dealer who will process your claim Three Year Limite...

Page 17: ...hoix toute chambre UV VIQUA d fectueuse Veuillez renvoyer la pi ce d fectueuse votre revendeur pour traitement de votre recours Garantie limit e de trois ans sur les composants mat riels et lectriques...

Page 18: ...nce et de s curit de l quipement d origine ne sont pas compromises Ainsi vous pouvez voir que a ne vaut pas la peine de prendre le risque Insistez sur des lampes UV de rechange d origine VIQUA Caract...

Page 19: ...tional de l lectricit NFPA 70 et fournir une protection suppl mentaire par rapport au risque de choc lectrique ce syst me ne devrait tre branch que sur une prise correctement mise la terre prot g e pa...

Page 20: ...it s physiques sensorielles ou mentales r duites ou un manque d exp rience et de connaissances ne doivent pas non plus manipuler le syst me UV moins qu elles soient supervis es ou form es Ce syst me e...

Page 21: ...duit la quantit de lumi re UV qui atteint l eau et limite donc les performances de d sinfection S il n est pas possible de nettoyer le manchon celui ci doit tre remplac Pr alables Couper l arriv e d...

Page 22: ...d brancher l alimentation avant d effectuer tout travail sur le syst me de d sinfection Toujours arr ter l coulement d eau et rel cher la pression d eau avant de proc der l entretien Inspecter r guli...

Page 23: ...e d rivation quipement en option pour les mod les PUV 8 et PUV 16 Alimente les lectrovannes les alarmes distance et les composeurs automatiques 14 Dispositif de commande Alimente et contr le la lampe...

Page 24: ...support de fixation du dispositif de commande au mur avec quatre vis 8 non fournies 4 Faire glisser le dispositif de commande sur le support de fixation Installation 5 Ins rer la carte de r f rence e...

Reviews: