Pelican PDF-1000VF Installation And Operation Manual Download Page 7

Filter Cartridges 

Filter Cartridge Life 

It is recommended to replace filter cartridges every six months or 1000 gallons of use.  However, your water quality can 
lead to circumstances such as diminished water flow, visible sediment, or unwanted taste and/or odor in your water, 
requiring the cartridges be replaced sooner. 

There are several variables that determine how long a cartridge will last.  
These include: 

1.

How much water you use, and

2.

How much sediment, chlorine, or other unwanted substances is in the water.

Filter Cartridge Replacement 

NOTE:  Contact your system supplier for replacement filter parts. 

1.

Turn off cold water supply to system and turn on faucet to release pressure.
NOTE:  Due to water leakage, place a pan or towel under sump.

2.

Unscrew and remove bottom of filter housing.  Locate and remove large O-ring, wipe clean of lubricant, and set aside.
Repeat for second and third housings.

3.

Discard used filter cartridges.

Caution:  Read “WARNING” information on the bleach container before using.

4.

Using a non-abrasive sponge or cloth, scrub the bottom of each housing, O-ring grooves, and caps with dish soap and
warm water.  Rinse thoroughly.  Then fill bottom of each housing 1/3 full with water.  Add 1TBSP (14.7ML) of
household bleach and scrub to disinfect.                .

5.

Lubricate O-rings with clean silicone grease.  Insert each O-ring in groove and press into place.

NOTE:  This step is important to ensure a proper housing seal.  Make certain each O-ring is seated level in its groove or
a leak may occur.

6.

Screw bottom of housing(s) with bleach water onto cap(s) without filter cartridge(s) and hand-tighten.  DO NOT OVER-

TIGHTEN.

7.

Turn on water supply.  Let faucet run for about 10 seconds, then turn off faucet and let stand for 20-30 minutes.

8.

Turn on faucet and allow bleach water to run out (about 3-5 minutes)

9.

Turn off water supply to system.  Remove bottom of housings and empty out water.

10. Insert each filter cartridge in bottom of appropriate filter housing.

IMPORTANT:  Be sure to remove any protective covering from the filters before inserting.

11. Screw bottom of housing(s) onto cap(s) and hand-tighten.  DO NOT OVER-TIGHTEN.  Make certain cap standpipe slips

into cartridge(s).

12. Reset effective life indicator to 1100 gallons (see instruction under “Setting Effective Life Indicator” on Page 6.)

NOTE:  Based on the setting sensitivity of the Effective Life Indicator (ELI), user should set the ELI to 1,100 gallons to
assure a 1,000 gallon cycle.

13. Turn on water to system.  Let faucet run for 10 minutes to remove trapped air and carbon fines.  Check system for

leaks.

REPLACEMENT FILTERS 

PDF-VF-R01 Filter 

PDF-VF-R02  Filter 

PDF-VF-R03  Block Filter 

Summary of Contents for PDF-1000VF

Page 1: ...ed by Pelican Water Systems 3060 Performance Circle Suite 2 DeLand FL 32723 Toll Free 877 842 1635 Rev Date 3 11 2016 Installation and Operation Manual System tested and certified to meet the requirem...

Page 2: ...place the defective product or part Pelican Water Systems will consider the customer s preference in good faith All claimed defective product must 1 be authorized for return by Pelican Water Systems w...

Page 3: ...ation source such as contamination by raw sewage Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts System is not intended to convert wastewater o...

Page 4: ...nstallation on 3 8 inch 10mm cold water line Numbered diagrams correspond with numbered steps Step 1 Installing the Saddle Valve Use of a cordless drill is recommended To protect yourself from serious...

Page 5: ...washer and lock washer on the threaded shaft e Thread on the lock nut Tighten lock nut by hand until tight Caution Do not over tighten the lock nut Hand tighten only Do not use pliers or wrench to ti...

Page 6: ...etting the Effective Life Indicator NOTE The effective life indicator is the white dial located on the center of the mounting bracket Each black mark on the dial represents 100 gallons 378 5L a Move t...

Page 7: ...f household bleach and scrub to disinfect 5 Lubricate O rings with clean silicone grease Insert each O ring in groove and press into place NOTE This step is important to ensure a proper housing seal M...

Page 8: ...nd then turn off faucet to check for leaks NOTE If leaks persist or if there are other leaks in system turn off water supply Problem No water or decreased water flow Correction Check flow at faucet Th...

Page 9: ...EXPLODED PARTS VIEW 9...

Page 10: ......

Page 11: ......