What the Drinking Water Purifier Will Do 

The PDF-1000VF is a water purification treatment system.  This system uses a triple filter design to reduce unwanted elements in your 
drinking water.  Possible elements may include chlorine, lead, virus, bacteria, cysts, particulates and numerous organic compounds.   

The PDF-1000VF utilizes the patented NanoCeram® and other technologies in a systematic approach to ensure the water supply conforms 
to EPA Guide Standard for the removal of 99.9999% Bacteria, 99.99% Viruses, and 99.95% Cysts.   The PDF-1000VF is designed to 
discontinue water flow when its capability to filter unwanted elements has been exhausted.  This will help safeguard the consumer against 
contaminated water.  Replace all filters every 6 months or 1000 gallons. 

NOTE:  A performance data sheet is included and lists what elements will be reduced from the water supply.  (Please note that not all 
elements may be present.)  This data sheet lists the individual contaminants and microbial reduction performance. 

The drinking water purifier system is designed to fit under the kitchen or bathroom sink or any other area that is suitable.  A COLD water 
supply pipe is required within a few feet.  If water supply pipe is farther than what the tube will reach, you can purchase longer lengths of 
tubing from your local home improvement center. 

 NOTE:  Make sure the tubing is acceptable for use on potable water supplies. 

Before You Start 

In order to receive all of the benefits of your microbiological drinking water purifier, be sure to read all steps in this guide
carefully and follow steps exactly.

This system is intended for use with municipal and/or well-supplied water only.  It is not intended for use with surface water such as
from a lake or runoff.

Do not use for the treatment of water that is visually contaminated (cloudy) or has an obvious contamination source, such as
contamination by raw sewage.

Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

System is not intended to convert wastewater or raw sewage into drinking water.

Installation and plumbing should comply with all local laws and regulations.  Consult with your licensed plumber.
NOTE: In Massachusetts, plumbing code 248 CMR 3.00 and 10.00 shall be adhered to.

The microbiological drinking water purifier works on water pressure of 30 psig (minimum) to 100 psig (maximum).  If your house
water pressure is over the maximum, install a pressure reducing valve in the water supply pipe to the filter system.

Do not install the microbiological drinking water purifier outside, or in extreme hot or cold temperatures.  Temperature of the
water supply to the under-sink drinking water filter system must be between 40

F and 100

F.  Do not install on hot water.

Do not use with water that is microbiologically unsafe or of unknown quality without disinfection before or after the system.

Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

Precautions 

This system is for “cold water” use only.

Protect filters against freezing, which can cause cracking of the filter and water leakage.

The rubber O-ring provides the water-tight seal between the cap and the bottom of the housing.  It is important that the
O-ring be properly seated in the groove below the threads of the housing or a water leak could occur.

To prevent costly repairs or possible water damage, the sump of plastic housings must be replaced every ten years.  If sump is
older than recommended, replace immediately.  Date sump for reference and indicate replacement date.

Specifications & Dimensions 

Supply Water Pressure . . . . . . . . . . 30 – 100 psig 

         Min - Max 

 (2.1-6.7 bar) 

Supply Water Temperature . . . . . . . .  40 - 100

F

 

Min. – Max.            

 (4.4 – 37.8

C) 

Service Flow Rate 
@60 psig  . . . . . . . . . . . . . . . (0.5 GPM @4.1 bar) 
Rated Service Life . . . . .  1000 gallons (3,785 L) 
Dimensions . . . . . . . . . . 15.5” H x 5.25” D x 14” L 

 (394mm x 133mm x 356mm) 

Weight . . . . . . . . (filled with water) 19lbs (8.6kg) 

3

 

Summary of Contents for PDF-1000VF

Page 1: ...ed by Pelican Water Systems 3060 Performance Circle Suite 2 DeLand FL 32723 Toll Free 877 842 1635 Rev Date 3 11 2016 Installation and Operation Manual System tested and certified to meet the requirem...

Page 2: ...place the defective product or part Pelican Water Systems will consider the customer s preference in good faith All claimed defective product must 1 be authorized for return by Pelican Water Systems w...

Page 3: ...ation source such as contamination by raw sewage Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts System is not intended to convert wastewater o...

Page 4: ...nstallation on 3 8 inch 10mm cold water line Numbered diagrams correspond with numbered steps Step 1 Installing the Saddle Valve Use of a cordless drill is recommended To protect yourself from serious...

Page 5: ...washer and lock washer on the threaded shaft e Thread on the lock nut Tighten lock nut by hand until tight Caution Do not over tighten the lock nut Hand tighten only Do not use pliers or wrench to ti...

Page 6: ...etting the Effective Life Indicator NOTE The effective life indicator is the white dial located on the center of the mounting bracket Each black mark on the dial represents 100 gallons 378 5L a Move t...

Page 7: ...f household bleach and scrub to disinfect 5 Lubricate O rings with clean silicone grease Insert each O ring in groove and press into place NOTE This step is important to ensure a proper housing seal M...

Page 8: ...nd then turn off faucet to check for leaks NOTE If leaks persist or if there are other leaks in system turn off water supply Problem No water or decreased water flow Correction Check flow at faucet Th...

Page 9: ...EXPLODED PARTS VIEW 9...

Page 10: ......

Page 11: ......

Reviews: