Installation Instructions 

Step 6 – Attaching Tube to Effective Life Indicator (ELI) 

a)

Determine the length of tubing needed from the faucet to the ELI. A slight sag in the
line will allow for some ease in installation.  Cut the tubing to required length.

b) Insert other end of tubing firmly into the outlet port (John Guest® fitting) of the ELI

until fully engaged.

c)

Pull tube gently to ensure the tubing is fully seated.

  Caution:  Tube must be fully inserted in the compression fitting base on the outlet stem of the ELI.  

Step 7 – Connecting the Saddle Valve 

a)

Determine the length of plastic tubing needed to connect the inlet (left) side of the filter
with the saddle valve.  Be sure to allow enough tubing to prevent kinking and cut the tubing
squarely.  Slide brass compression nut onto tubing, followed by plastic ferrule.  The long tapered
end of the ferrule should face towards the end of the tubing.  Place insert into tubing.

b) Insert tubing into saddle valve and hand-tighten compression nut.  Using a wrench, tighten nut

1 to 1 ½ turns.

 NOTE: All nuts must be retightened when the system reaches projected operating temperature. 

Step 8 – Connecting Inlet Line to System 

a)

Insert other end of tubing firmly into inlet port (John Guest® fitting) until fully engaged.

b) Pull tube gently to ensure the tubing is fully seated.

Step 9 – Setting the Effective Life Indicator 

        NOTE:  The effective life indicator is the white dial located on the center of the mounting bracket. 
        Each black mark on the dial represents 100 gallons (378.5L).   

a)

Move the dial clockwise so that the black indicator arrow lines up with the 1100 gallon
(4,164 L) mark.

        Important:  Set flow meter to 1100 gallons after each new filter replacement. 
        NOTE: To prevent indicator malfunctions, only move the dial when the system is depressurized. 

 NOTE:  Based on the settings sensitivity of the Effective Life Indicator (ELI), user should set the  

         ELI to 1,100 gallons to assure a 1,000 gallon cycle. 

Step 10 – Putting the System into Operation 

a)

Slowly turn on cold water supply.

b) Rotate handle on base of drinking water faucet counter-clockwise to “ON” position.

Allow water to run for 10 minutes to flush air and carbon fines from filter cartridges.
Check system for leaks before completing installation.

c)

Make sure that all nuts are tightened.

NOTE:  A drinking water cartridge may contain carbon fines (very fine black powder). It is
recommended that you run the tap at least 20 seconds prior to using water for drinking or
cooking purposes.
NOTE:  Initially, filtered water may appear cloudy.  If you set a glass of water on a level surface, you
should be able to watch the cloudiness disappear from the bottom of the glass upwards.  This harmless cloudiness
results from the release of trapped air with the cartridge and will disappear within a few weeks after installation.

INSTALLATION IS NOW COMPLETE. 

Summary of Contents for PDF-1000VF

Page 1: ...ed by Pelican Water Systems 3060 Performance Circle Suite 2 DeLand FL 32723 Toll Free 877 842 1635 Rev Date 3 11 2016 Installation and Operation Manual System tested and certified to meet the requirem...

Page 2: ...place the defective product or part Pelican Water Systems will consider the customer s preference in good faith All claimed defective product must 1 be authorized for return by Pelican Water Systems w...

Page 3: ...ation source such as contamination by raw sewage Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts System is not intended to convert wastewater o...

Page 4: ...nstallation on 3 8 inch 10mm cold water line Numbered diagrams correspond with numbered steps Step 1 Installing the Saddle Valve Use of a cordless drill is recommended To protect yourself from serious...

Page 5: ...washer and lock washer on the threaded shaft e Thread on the lock nut Tighten lock nut by hand until tight Caution Do not over tighten the lock nut Hand tighten only Do not use pliers or wrench to ti...

Page 6: ...etting the Effective Life Indicator NOTE The effective life indicator is the white dial located on the center of the mounting bracket Each black mark on the dial represents 100 gallons 378 5L a Move t...

Page 7: ...f household bleach and scrub to disinfect 5 Lubricate O rings with clean silicone grease Insert each O ring in groove and press into place NOTE This step is important to ensure a proper housing seal M...

Page 8: ...nd then turn off faucet to check for leaks NOTE If leaks persist or if there are other leaks in system turn off water supply Problem No water or decreased water flow Correction Check flow at faucet Th...

Page 9: ...EXPLODED PARTS VIEW 9...

Page 10: ......

Page 11: ......

Reviews: