d) Add one cap full of bleach to the Activated
Carbon Post Filter Housing. Carefully fill the
housing with tap water and temporarily install
the hous ing, without the Ac ti vat ed Carbon
Post Filter.
e) The Dispensing Faucet should be open, slowly
open the Saddle Tapping Valve on the Feed
Water Line.
f) As soon as water begins to drip out of the Dis -
pens ing Faucet, close the Faucet.
g) Let the system stand for 15 minutes.
h) At the end of 15 minutes, in the following
order, close the Saddle Tapping Valve, close
the Hold ing Tank Valve and open the
Dispensing Faucet to release the pressure.
i) Remove the Post Carbon Filter Housing and
emp ty (Repeat procedure if your system has a
Pre Carbon Filter Housing). Remove any
wrapping/pack ag ing from carbon cartridge (s)
and install in hous ings. Check the O-ring to
insure that it is po si tioned properly in its
groove and replace Housing(s) on R.O. unit.
j) Disconnect the yellow product water tubing
that runs from the Holding Tank. Put 50 drops
of bleach (this is 1/2 tsp. or 3 ml) into the tub-
ing and reconnect it.
k) Slowly open the Saddle Tapping Valve. When
water begins dripping out of the Dispensing
Fau cet, in the following order, close the Faucet
and then open the Holding Tank Valve.
l) Do not open the Faucet for at least 8 hours.
m) Discard the first two full tanks of water pro-
duced, they will contain chlorine.
n) When the Faucet is first opened, expect air
and carbon fines (very fine black powder),
from the new carbon filter (s) to be rinsed out.
This is normal for the first tank of water.