64
EN
3.4 Datasheet - MIRUS LINE
Max. DC Power
Max. DC Voltage
MPPT Voltage range
Nominal DC Voltage
Start Voltage
Min. DC Voltage
Max. DC Input Current
Number of DC Connection
Sets per MPPT
Number of MPPT
DC Switch
1800 W
450 V
60-425 V
360 V
70 V
50 V
11 A
1
Integrated
1
Integrated
1200 W
450 V
60-425 V
360 V
70 V
50 V
11 A
1
1
PSI-J1000-TL
PSI-J1500-TL
Input DC
Rated AC Power
Max. AC Power
Rated AC Current
Max. AC Current
Nominal AC voltage / Range
Grid frequency / range
Power factor [cos
φ
]
Total Harmonic Distortion
Feed in
Output AC
220 V, 230 V, 240 V / 180 V - 280 V
50 Hz, 60 Hz / ±5 Hz
> 0.99 (full load)
< 3%
1L + N + PE
1500 W
1650 W
6.5 A
7.9 A
1000 W
1100 W
4.3 A
5.3 A
Protection
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
AFD
Internal Over-voltage Protection
DC Insulation Monitoring
DCI Monitoring
GFCI Monitoring
Grid Monitoring
AC Short Circuit Current Protection
Thermal Protection
Anti-island protection monitoring