Check the volt of the grid.

• 

Check the connection between the inverter and the grid.

• 

Check the settings of the on-grid standards of the inverter.

• 

If the voltage of the grid is higher than the standard value, 
please conctact the Distribution Network Operator (DNO) for 
the adjustment at the feed point or for the modification of the 
regulated voltage value.

• 

If the volt of the grid is in regulated range as allowed and 
LCD still in this error, please contact your DNO or phone 
Peimar.

Check the set of country and check the frequency of the local 
grid, if the above mentioned are normal, please contact your DNO 
or contact Peimar assistance.

Frequency Error

Check the connection status between the AC side of the inverter 
and the grid, if the above mentioned are in normal, please contact 
your distributor or contact Peimar assistance.

No Grid Error

If this error exists always, please contact your DNO or contact 
Peimar assistance.

DCI Error

Check the insulation resistance of the positive side and negative 
side of the solar panel; check whether the inverter is in wet 
environment; check the grounding of the inverter. If the above 
mentioned are normal, please contact your DNO or contact 
Peimar assistance.

GFCI Error

Check the insulation resistance of the positive side and negative  
side of the solar panel; check whether the inverter is in wet 
environment; check whether the grounding of the inverter is loose 
or not. If the above mentioned are normal, please contact your 
DNO or contact Peimar assistance.

ISO Error

Check the connection status between the inverter and the grid 
and test whether the volt of the grid is stable or not, if the above 
mentioned are normal, please contact your DNO or contact 
Peimar assistance.

Current High

Check the settings of the solar panel. Peimar designer can help 
you. If the above mentioned are normal, please contact your DNO 
or contact Peimar assistance.

Bus Voltage High

AC Voltage Error

If this error occurs frequently, please contact your DNO or contact 
Peimar assistance.

Current Sensor Error

Summary of Contents for Geminus PSI-J3000-TLM

Page 1: ...IT EN ES Manuale dell Utente Inverter Monofase 3 User Manual Single Phase Inverters 55 Manual de Usuario Inversor Monofásico 107 MIRUS LINE UNICUS LINE GEMINUS LINE www peimar com ...

Page 2: ......

Page 3: ...zionamento e la manutenzione del prodotto da voi acquistato nonché le indispensabili linee guida relative alla sicurezza e le istruzioni per la risoluzione di eventuali problemi Si prega di leggere attentamente il presente documento e di seguirne le indicazioni in modo tale da consentirci di fornirvi la nostra consulenza professionale e un completo servizio d assistenza Il nostro impegno è costant...

Page 4: ...tto 11 3 3 Prospetto e dimensioni dei prodotti 11 3 4 Scheda tecnica MIRUS LINE 12 3 5 Scheda tecnica UNICUS LINE 14 3 6 Scheda tecnica GEMINUS LINE 16 Capitolo 4 Istruzioni per l installazione 18 4 1 Istruzioni di sicurezza 18 4 2 Controllo prima dell installazione 18 4 3 Individuazione metodo e posizione di installazione 19 4 4 Procedura di montaggio 20 Capitolo 5 Connessione elettrica 25 5 1 Is...

Page 5: ...isplay dell inverter 36 6 4 Impostare i parametri generali dell inverter 38 6 5 Auto test completo dell inverter 42 6 6 Auto test singoli dell inverter 43 6 7 Operazione di Monitoraggio 47 Capitolo 7 Codici di errore e risoluzione dei problemi 48 7 1 Codice errore e descrizione 48 7 2 Indicazione errore e risoluzione del problema 49 Capitolo 8 Riciclaggio e Smaltimento 52 Capitolo 9 Servizio di Ga...

Page 6: ... installazione la manutenzione e la riparazione dell inverter possono essere effettuate unicamente da personale qualificato che abbia letto e compreso pienamente tutti i regolamenti di sicurezza contenuti in questo manuale Gli operatori devono essere al corrente del fatto che l inverter è un dispositivo ad alta tensione PERICOLO indica una situazione pericolosa che se non evitata porterà a morte o...

Page 7: ...per permettere ai condensatori di accumulo energetico di scaricarsi completamente dopo essersi disconnessi dalla fonte di energia AVVERTENZA L installazione manutenzione riciclaggio e smaltimento degli inverter devono essere svolti solamente da personale qualificato in conformità con le norme e i regolamenti nazionali e locali Qualsiasi azione non autorizzata tra cui la modifica di qualsiasi tipo ...

Page 8: ... ad alcun dispositivo che non sia collegato alla rete elettrica di distribuzione pubblica 2 2 Spiegazione dei simboli TENSIONE ELETTRICA PERICOLOSA Questo dispositivo è direttamente connesso alla rete elettrica pubblica pertanto qualsiasi lavoro sull inverter deve essere svolto da personale qualificato PERICOLO di morte dovuto ad alta tensione elettrica Nell inverter si può avere una tensione resi...

Page 9: ...risoluzione MESSA A TERRA Punto di connessione del conduttore di protezione per la messa a terra Marchio CE I dispositivi con il marchio CE rispettano i requisiti fondamentali della Direttiva Bassa Tensione e della Direttiva Compatibilità Elettromagnetica ROHS Restriction of Hazardous Substances Directive Questo dispositivo NON DEVE essere smaltito come rifiuto urbano Si rimanda al Capitolo 8 Rici...

Page 10: ...ere dunque utilizzata per l alimentazione delle utenze elettriche dell abitazione o della propria attività e per poter immettere in rete il surplus La Tabella 3 1 mostra lo schema strutturale del tipico sistema di applicazione degli inverter Tabella 3 1 Schema di configurazione Moduli fotovoltaici in silicio monocristallino o policristallino e a film sottile con protezione di livello II e senza bi...

Page 11: ... di doppio MPPT dell inverter 3 3 Panoramica e dimensioni dei prodotti Le dimensioni dei prodotti sono indicate nella Figura 3 2 Figura 3 2 Dimensioni dei prodotti Mirus Unicus e Geminus PSI JXXXX TL PSI JXXXX TLM 305 mm 120 354 mm SERIE UNICUS PSI J2000 TL PSI J2500 TL PSI J3000 TL 355 mm 150 162 mm 454 PSI J3000 TLM PSI J4000 TLM PSI J5000 TLM PSI J6000 TLM SERIE GEMINUS 260 mm 120 mm 315 mm PSI...

Page 12: ...minale CA Potenza massima CA Corrente nominale CA Corrente massima CA Tensione nominale CA Range Frequenza di rete Range Fattore di potenza cos φ Distorsione armonica totale Connessione Uscita CA 220 V 230 V 240 V 180 V 280 V 50 Hz 60 Hz 5 Hz 0 99 a pieno carico 3 Monofase 1L N PE 1500 W 1650 W 6 5 A 7 9 A 1000 W 1100 W 4 3 A 5 3 A Protezione sovratesione interna Monitoraggio isolamento CC Monitor...

Page 13: ...rotezione Montaggio Dimensioni H x L x P mm Peso netto Garanzia Anno Senza trasformatore 0 2 W 6 W Da 25 C a 60 C 45 C a 60 C con derating Convezione naturale Da 0 a 100 senza condensa Fino a 2000 m senza derating 15 dBA II ingresso CC III uscita CA IP65 Installazione interna ed esterna Staffa di fissaggio a parete 315 x 260 x 120 5 6 kg 5 standard 10 opzionale Interfaccia Connessione CA Connessio...

Page 14: ...one di avvio Tensione minima CC Corrente di ingresso massima CC Numero di ingressi CC per ogni MPPT Numero di MPPT Sezionatore CC DC21B Potenza nominale CA Potenza massima CA Corrente nominale CA Corrente massima CA Tensione nominale CA Range Frequenza di rete Range Fattore di potenza cos φ Distorsione armonica totale Connessione Protezione 3 5 Scheda tecnica UNICUS LINE Protezione sovratesione in...

Page 15: ...urno Consumo in Standby Range di temp in funzionamento Metodo di raffreddamento Umidità ambientale Altitudine Rumore Categoria di Sovratensione Grado di protezione Montaggio Dimensioni H x L x P mm Peso netto Garanzia Anno Certificati Per un elenco completo dei certificati fare riferimento al sito www peimar com Senza trasformatore 0 2 W 6 W Da 25 C a 60 C 45 C a 60 C con derating Convezione natur...

Page 16: ...ione nominale CC Tensione di avvio Tensione minima CC Corrente di ingresso massima CC Numero di ingressi CC per ogni MPPT Numero di MPPT Sezionatore CC DC21B Potenza nominale CA Potenza massima CA Corrente nominale CA Corrente massima CA Tensione nominale CA Range Frequenza di rete Range Fattore di potenza cos φ Distorsione armonica totale Connessione Protezione 46002 5000 W 4600 5500 W 20 0 21 7 ...

Page 17: ...derating 25 dBA II ingresso CC III uscita CA IP65 Installazione interna ed esterna Staffa di fissaggio a parete 5 standard 10 opzionale 454 x 355 x 162 15 8 kg 454 x 355 x 150 14 8 kg Topologia Consumo notturno Consumo in Standby Range di temp in funzionamento Metodo di raffreddamento Umidità ambientale Altitudine Rumore Categoria di Sovratensione Grado di protezione Montaggio Dimensioni H x L x P...

Page 18: ...opriato o non conforme può compromettere la durata dell inverter Si sconsiglia l installazione dell inverter con esposizione diretta ai raggi solari Il luogo di installazione deve essere ben ventilato 4 2 Controllo prima dell installazione 4 2 1 Controllare l imballaggio Sebbene gli inverter Peimar abbiano superato collaudi rigorosi e vengano controllati prima che lascino la fabbrica non è escluso...

Page 19: ...in avanti di lato orizzontale o in posizione capovolta 3 Installare l inverter ad altezza uomo per facilitare la visualizzazione del display e le possibili attività di manutenzione 4 Effettuare l installazione dell inverter prevedendo la possibilità di smontaggio per lavori di manutenzione 4 3 2 Posizione di installazione Non esporre l inverter alla luce solare diretta questo potrebbe causare una ...

Page 20: ...sicurezza indicate nella Figura 4 2 4 4 Procedura di montaggio 4 4 1 Segnare i punti di perforazione per il montaggio della staffa di ancoraggio La posizione di montaggio deve essere segnata come mostrato nella Figura 4 3 Figura 4 4 e Figura 4 5 Figura 4 2 Distanze minime Figura 4 3 Dimensioni della staffa di PSI J1000 TL PSI J1500 TL 252 9 211 239 188 265 40 20 20 16 ø 8 30 cm 50 cm 50 cm 30 cm 3...

Page 21: ... e Figura 4 8 Successivamente inserirvi i tasselli di fissaggio utilizzando un martello di gomma Figura 4 4 Dimensioni della staffa di PSI J2000 TL PSI J2500 TL PSI J3000 TL Figura 4 5 Dimensioni della staffa di PSI J3000 TLM PSI J4000 TLM PSI J5000 TLM PSI J6000 TLM Figura 4 6 Dimensioni dei fori di PSI J1000 TL PSI J1500 TL 296 9 283 255 77 5 77 5 92 311 40 20 7 2 7 2 4 ø8 305 289 240 86 43 188 ...

Page 22: ...LM PSI J4000 TLM PSI J5000 TLM PSI J6000 TLM 4 4 3 Applicare le viti e montare la staffa di ancoraggio Le staffe devono essere installate nella posizione di montaggio tramite viti come mostrato nella Figura 4 9 Figura 4 10 e Figura 4 11 Figura 4 9 Montaggio della staffa di PSI J1000 TL PSI J1500 TL 247 77 59 2 ø8 240 120 ø8 ...

Page 23: ...23 IT Figura 4 10 Montaggio della staffa di PSI J2000 TL PSI J2500 TL PSI J3000 TL Figura 4 11 Montaggio della staffa di PSI J3000 TLM PSI J4000 TLM PSI J5000 TLM PSI J6000 TLM ...

Page 24: ...teriore del dispositivo sia montata a stretto contatto con la staffa Utilizzare le due viti apposite per bloccare l inverter alla staffa Figura 4 12 Montaggio dell inverter PSI J1000 TL PSI J1500 TL Figura 4 13 Montaggio dell inverter PSI J2000 TL PSI J2500 TL PSI J3000 TL Figura 4 14 Montaggio dell inverter PSI J3000 TLM PSI J4000 TLM PSI J5000 TLM PSI J6000 TLM ...

Page 25: ...che Al momento dell accensione il dispositivo deve essere conforme alle norme e ai regolamenti nazionali La connessione tra il convertitore e la rete di distribuzione elettricadeveessereeffettuatadatecniciqualificatiinconformità alle norme e ai regolamenti nazionali e locali della rete elettrica AVVERTENZA Quando l impianto fotovoltaico è esposto alla luce fornisce all inverter una tensione CC AVV...

Page 26: ...nessione di PSI J1000 TL PSI J1500 TL PSI J2000 TL PSI J2500 TL PSI J3000 TL Figura 5 2 Ingressi di connessione di PSI J3000 TLM PSI J4000 TLM PSI J5000 TLM PSI J6000 TLM Tabella 5 1 Ingressi di connessione A Ingresso CC B RS 232 Porta Wi Fi C Presa di connessione CA D Sezionatore CC ...

Page 27: ...4 Connettere i cavi Figura 5 3 Infilare il cavo Sezione dei cavi mm Diametro esterno dei cavi mm 4 0 6 0 4 0 4 2 5 3 Minimo massimo Valore consigliato 5 3 1 Infilare il cavo CA nel pressacavo impermeabile 5 3 3 Fissare saldamente tutte le parti del connettore CA 5 3 2 Connettere i cavi secondo i segni di connessione di L N e PE ...

Page 28: ...usa Figura 5 6 Connettere l inverter Tabella 5 3 Caratteristiche raccomandate per i cavi CC Figura 5 7 Connettore positivo 5 4 Connessione dal lato CC La connessione CC è costituita dal connettore positivo e dal connettore negativo Involucro isolante Vite di bloccaggio Sezione dei cavi mm Diametro esterno dei cavi mm 4 0 6 0 4 0 4 2 5 3 Minimo massimo Valore consigliato ...

Page 29: ...vere la guaina isolante del cavo positivo e di quello negativo per la lunghezza opportuna Cavo positivo L1 L1 L2 8 10mm L2 8 10mm Cavo negativo AVVISO Posizionare separatamente il connettore dopo il disimballaggio per evitare errori nella connessione dei cavi Collegare il connettore positivo al polo positivo dei pannelli solari e il connettore negativo al polo negativo dei pannelli solari Assicura...

Page 30: ... dovrebbe sentire o percepire uno scatto quando il cavo crimpato viene posizionato correttamente 6 Chiudere le viti di bloccaggio sui connettori positivi e negativi nel rispettivo involucro isolante e stringerle 7 Collegare i connettori positivo e negativo nei rispettivi terminali di ingresso CC dell inverter si dovrebbe sentire o percepire uno scatto quando i connettori sono collegati correttamen...

Page 31: ...Detect 2 RxD Received Data 3 TxD Transmitted Ready 4 DTR Data Terminal 5 GND Signal Ground 6 DSR Data Send Ready 7 RTS Request To Send 8 CTS Clear To Send 9 RI Ring Indicator Figura 5 11 Porta seriale a 9 pin Tabella 5 5 Istruzioni di cablaggio della porta seriale a 9 pin 5 5 Connessione dell interfaccia di comunicazione Gli inverter Mirus Unicus e Geminus sono dotati di un interfaccia RS 232 6 5 ...

Page 32: ...ORE LED verde FUNZIONAMENTO La spia verde è accesa durante il normale funzionamento del dispositivo B C D E F Il display mostra i dati operativi le informazioni e i parametri registrati Tasto Esci Tasto Invio Tabella 6 1 Istruzioni dell interfaccia La spia rossa si accende al rilevamento di un errore La spia rossa si spegne dopo la risoluzione degli errori DISPLAY Figura 6 1 Interfaccia uomo macch...

Page 33: ...irà come mostrato di seguito I tasti presenti sull inverter consentono di navigare nel menu per richiedere informazioni sul funzionamento e sui parametri operativi Questi due pulsanti possono essere usati ripetitivamente Tabella 6 2 Istruzioni per i tasti Sposta in basso il cursore o riduce il valore numerico selezionato Sposta in alto il cursore o aumenta il valore numerico selezionato Torna al m...

Page 34: ...rrore Attesa Aggiornamento Figura 6 4 Conto alla rovescia in secondi Connessione rete Attendere 30s Premere il tasto ENT il display mostrerà le opzioni di Paese da selezionare Premendo i tasti o spostare il cursore fino a selezionare il Paese corretto e premere quindi il pulsante ENT per confermare la selezione In seguito impostare data e ora Attenzione la scelta del Paese di utilizzo deve essere ...

Page 35: ...35 IT Note ...

Page 36: ... 0 00 kWh P ca 21 W Errore attuale Storico Errori IP 0 0 0 0 2018 10 30 17 23 Stato Normale P ca 344 W V ca 227 9 V I ca 1 58 A f ca 50 03 Hz V PV1 170 5 V I PV1 2 36 A V PV2 0 0 V I PV2 0 00 A Temp 28 8 C Imp parametri Info inverter Periferica Auto test Valori attuali Statistiche ENT ENT ENT ENT ENT ...

Page 37: ...ete Azzera energia Reset fabbrica Lingua Data Numero di serie Codice Prodotto T Oggi 0 5 h T Totale 0 5 h E Oggi E Mese E Anno E Totale T Oggi T Totale Vers Firmware SN xxxxxxxxxxxxx PC xxxxxxxxxxxxx Modello Inverter PSI Jxxxx xx Italia 0 21 CEI0_21 MCUF Vx xxx SCUF Vx xxx DBF Vx xxx Prego inserire Password 1 Australia 2 Austria Errore 24 Errore 24 18 10 30 13 20 18 09 30 10 23 ENT ENT ENT ENT ENT...

Page 38: ...lori attuali Statistiche Valori attuali Statistiche Imp parametri Info inverter Lingua Data Lingua x x Italiano Confermare le modifiche ENT ENT ENT ENT E oggi 0 00 kWh P ca 21 W Set Completato ENT Set Completato Imp parametri Info inverter Lingua Data Lingua Data Data 2018 10 30 Confermare le modifiche ENT ENT ENT ENT ENT ...

Page 39: ...ngua Data Ora Standard Rete Ora 15 35 23 Confermare le modifiche Set Completato ENT ENT ENT E oggi 0 00 kWh P ca 21 W Valori attuali Statistiche Imp parametri Info inverter Lingua Data Set Completato Ora Standard Rete L inverter si riavvia automaticamente Prego inserire Password 1 Australia 2 Austria ENT ENT ENT ENT ENT ENT Confermare le modifiche 15 Italia 0 21 16 Portogallo ...

Page 40: ...a Password Cancella Errori Prego inserire Password Inserire nuova Password ENT ENT ENT ENT Set Completato Imposta nuova password ENT Valori attuali Statistiche ENT E oggi 0 00 kWh P ca 21 W Imp parametri Info inverter Lingua Data Cambia Password Cancella Errori ENT ENT Confermare le modifiche Set Completato ENT Prego inserire Password ENT Valori attuali Statistiche ENT ...

Page 41: ...a Reset fabbrica Prego inserire Password ENT ENT ENT Confermare le modifiche Set Completato ENT Valori attuali Statistiche ENT E oggi 0 00 kWh P ca 21 W Imp parametri Info inverter Lingua Data Azzera energia Reset fabbrica Prego inserire Password ENT ENT ENT ENT Set Completato Confermare le modifiche Valori attuali Statistiche ENT L inverter si riavvia automaticamente ...

Page 42: ...st completo 0 0 risultato 9 Test completo 1 Ovp 59 S2 2 Ovp10 59 S1 Periferica Auto test Valori attuali Statistiche ENT ENT ENT 1 Ovp 59 S2 Vs230 7V To190ms 1 Ovp 59 S2 Vt264 5V Tt200ms TestCompleto 0 0 risultato Test superato 6 5 Auto test completo dell inverter Solo nei casi in cui il paese impostato sia Italia 0 21 ...

Page 43: ... Auto test 1 Ovp 59 S2 2 Ovp10 59 S1 Ovp10 59 S1 0 0 risultato Ovp10 59 S1 1 1 test 2 Ovp10 59 S1 Attendere 599s Test superato ENT ENT ENT ENT Valori attuali Statistiche Periferica Auto test 1 Ovp 59 S2 2 Ovp10 59 S1 Ovp 59 S2 0 0 risultato Ovp 59 S2 1 1 test 1 Ovp 59 S2 Attendere 599s Test superato ENT ENT ENT 1 Ovp 59 S2 Vt264 5V Tt200ms Vs230 7V To190ms Vo230 2V Pass 2018 10 29 08 00 TestComple...

Page 44: ...to test 3 Uvp 27 S1 4 Uvp2 27 S2 Uvp 27 S1 0 0 risultato Uvp 27 S1 1 1 test 3 Uvp 27 S1 Attendere 599s Test superato ENT ENT ENT ENT Valori attuali Statistiche Periferica Auto test 3 Uvp 27 S1 4 Uvp2 27 S2 Uvp2 27 S2 0 0 risultato Uvp2 27 S2 1 1 test 4 Uvp2 27 S2 Attendere 599s Test superato ENT ENT ENT ENT ...

Page 45: ...i Statistiche Periferica Auto test Periferica Auto test 5 Ofp 81 S1 6 Ofp2 81 S2 5 Ofp 81 S1 6 Ofp2 81 S2 Ofp 81 S1 0 0 risultato Ofp2 81 S2 0 0 risultato Ofp 81 S1 1 1 test Ofp2 81 S2 1 1 test 5 Ofp 81 S1 Attendere 599s 6 Ofp2 81 S2 Attendere 599s Test superato Test superato ENT ENT ENT ENT ENT ENT ENT ENT ENT ...

Page 46: ...li Statistiche Periferica Auto test Periferica Auto test 7 Ufp 81 S1 8 Ufp2 81 S2 7 Ufp 81 S1 8 Ufp2 81 S2 Ufp 81 S1 0 0 risultato Ufp2 81 S2 0 0 risultato Ufp 81 S1 1 1 test Ufp2 81 S2 1 1 test 7 Ufp 81 S1 Attendere 599s 8 Ufp2 81 S2 Attendere 599s Test superato Test superato ENT ENT ENT ENT ENT ENT ENT ENT ...

Page 47: ...7 Operazione di monitoraggio Il dispositivo è equipaggiato con un interfaccia RS 232 Essa può essere connessa al modulo Wi Fi utlizzabile per il monitoraggio dello stato di funzionamento Il dispositivo può connettersi alla rete internet locale tramite un modulo Wi Fi ed il web server integrato nel dispositivo in tal modo si può monitorare lo stato di funzionamento dell inverter Connettendosi alla ...

Page 48: ...renza dei dati di tensione Slave Errore relè Master Temperatura elevata Master Errore memoria EEPROM Master Errore dispositivi GFCI Master Errore dispositivi DCI Master Errore sensore di corrente Master Tensione di rete elevata Master Tensione di rete bassa Master Tensione media di 10 minuti elevata Master Frequenza elevata Master Errore 19 Errore 04 Errore 24 Errore 33 Errore 40 Errore 05 Errore ...

Page 49: ...te pregati di contattare il vostro rivenditore o l assistenza tecnica Peimar Errore dispositivo GFCI Se questo errore si verifica spesso siete pregati di contattare il vostro rivenditore o l assistenza tecnica Peimar Errore dispositivi DCI Errore di coerenza dei dati di frequenza Slave Errore 54 Tensione della rete elettrica elevata Slave Errore coerenza dati GFCI Slave Tensione della rete elettri...

Page 50: ...ca Peimar Errore DCI Controllare la resistenza di isolamento del lato positivo e del lato negativo dei pannelli solari verificare che l inverter non si trovi in un ambiente bagnato controllare la corretta messa a terra dell inverter Se le suddette condizioni sono nella norma siete pregati di contattare il vostro rivenditore o l assistenza tecnica Peimar Errore GFCI Controllare la resistenza di iso...

Page 51: ... suddette condizioni sono nella norma siete pregati di contattare il vostro rivenditore o l assistenza tecnica Peimar Errore di tensione PV Controllare la connessione dei cavi di comunicazione tra la scheda di controllo e la scheda di visualizzazione Se le suddette condizioni sono nella norma siete pregati di contattare il vostro rivenditore o l assistenza tecnica Peimar Comunicazione persa Tabell...

Page 52: ...t www peimar com Capitolo 8 Riciclaggio e Smaltimento Questo dispositivo non deve essere smaltito come rifiuto urbano Quando un inverter ha raggiunto la fine della sua vita utile e non è più utilizzabile è necessario restituirlo al proprio rivenditore o smaltirlo presso un centro autorizzato di raccolta e riciclaggio nella propria zona ...

Page 53: ...53 IT Note ...

Page 54: ......

Page 55: ...exceptional technical service This manual includes all relevant information for the installation operation maintenance trouble shooting and safety of the Peimar inverter Please follow the instructions on this manual closely to ensure that this product meets all safety requirements and that you are able to obtain as much benefit and long life from it as possible At Peimar we are fully committed to ...

Page 56: ... for product model 63 3 3 Overview and dimensions of products 63 3 4 Datasheet MIRUS LINE 64 3 5 Datasheet UNICUS LINE 66 3 6 Datasheet GEMINUS LINE 68 Chapter 4 Instructions for installation 70 4 1 Safety instructions 70 4 2 Pre installation check 70 4 3 The determination of the installation method and position 71 4 4 Mounting procedure 72 Chapter 5 Electrical connection 77 5 1 Safety instruction...

Page 57: ...ay of the inverter 88 6 4 Settings of general parameters of the inverter 90 6 5 Complete Selftest of the inverter 94 6 6 Individual Selftest of the inverter 95 6 7 Monitoring operation 99 Chapter 7 Fault code and troubleshooting 100 7 1 Fault code and explanation 100 7 2 Fault information and troubleshooting 101 Chapter 8 Recycling and Disposal 104 Chapter 9 Guarantee Service 104 ...

Page 58: ...uctions 1 3 Target group Only qualified electricians who have read and fully understood all safety regulations contained in this manual can install maintain and repair the inverter Operators must be aware of the high voltage device DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING indicates a hazardous situation which if not avoided can resu...

Page 59: ...connected from the grid and PV generator you must wait for at least five minutes to let the energy storage capacitors fully be discharged after disconnecting from power source WARNING The installation service recycling and disposal of the inverters must be performed by qualified personnel only in compliance with national and local standards and regulations Any unauthorized actions including modifi...

Page 60: ...ns of symbols DANGEROUS ELECTRICAL VOLTAGE This device is directly connected to public grid thus all work to the inverter shall only be carried out by qualified personnel DANGER to life due to high electrical voltage There might be residual currents in inverter because of large capacitors Wait for 5 MINUTES before you remove the front lid NOTICE DANGER This is directly connected with electricity g...

Page 61: ...mark fulfills the basic requirements of the Guideline Governing Low Voltage and Electro magnetic Compatibility ROHS Restriction of Hazardous Substances Directive This device SHALL NOT be disposed of as residential waste Please go to Chapter 8 Recycling and Disposal for proper treatments WITHOUT TRANSFORMER This inverter does not use transformer for the isolation function ...

Page 62: ...accordance with the requirements of public grid and send the AC into the grid Table 3 1 shows the structural diagram of the typical application system of PSI J inverters Table 3 1 Systematic configuration diagram Monocrystalline or polycrystalline silicon and thin film PV modules with II protection and need no ground connection Standard metering tool for measuring the output electric power of inve...

Page 63: ...he function of dual MPPT 3 3 Overview and Dimensions of products The dimensions of products is shown in Figure 3 2 Figure 3 2 Dimensions of Mirus Unicus Geminus series PSI JXXXX TL PSI JXXXX TLM 305 mm 120 354 mm SERIES UNICUS PSI J2000 TL PSI J2500 TL PSI J3000 TL 355 mm 150 162 mm 454 PSI J3000 TLM PSI J4000 TLM PSI J5000 TLM PSI J6000 TLM SERIES GEMINUS 260 mm 120 mm 315 mm PSI J1000 TL PSI J15...

Page 64: ... Power Max AC Power Rated AC Current Max AC Current Nominal AC voltage Range Grid frequency range Power factor cos φ Total Harmonic Distortion Feed in Output AC 220 V 230 V 240 V 180 V 280 V 50 Hz 60 Hz 5 Hz 0 99 full load 3 1L N PE 1500 W 1650 W 6 5 A 7 9 A 1000 W 1100 W 4 3 A 5 3 A Protection Integrated Integrated Integrated Integrated Integrated Integrated Integrated AFD Internal Over voltage P...

Page 65: ...less 0 2 W 6 W From 25 C to 60 C 45 C to 60 C with derating Natural Convection From 0 to 100 Non condensing Up to 2000 m without derating 15 dBA II DC input III AC output IP65 Indoor Outdoor Installation Rear Panel 315 x 260 x 120 5 6 kg 5 standard 10 optional AC Connection DC Connection LCD LED Display Display Language Datalogger Communication Interface Plug in connector MC4 H4 LCD 16 x 2 charact...

Page 66: ...Power Rated AC Current Max AC Current Nominal AC voltage Range Grid frequency range Power factor cos φ Total Harmonic Distortion Feed in 220 V 230 V 240 V 180 V 280 V 50 Hz 60 Hz 5 Hz 0 99 full load 3 1L N PE 2000 W 2200 W 8 7 A 10 6 A 3000 W 3300 W 13 0 A 15 9 A 2500 W 2750 W 10 9 A 13 3 A Protection Integrated Integrated Integrated Integrated Integrated Integrated Integrated AFD 3 5 Datasheet UN...

Page 67: ...ificates visit www peimar com General Data Topology Consumption at Night Consumption at Standby Operating Temperature Range Cooling Method Ambient Humidity Altitude Noise Overvoltage Rating Ingress Protection Mounting Dimensions H x W x D mm Net Weight Warranty Year Transformerless 0 2 W 6 W From 25 C to 60 C 45 C to 60 C with derating Natural Convection From 0 to 100 Non condensing Up to 2000 m w...

Page 68: ...r Max AC Power Rated AC Current Max AC Current Nominal AC voltage Range Grid frequency range Power factor cos φ Total Harmonic Distortion Feed in 220 V 230 V 240 V 180 V 280 V 50 Hz 60 Hz 5 Hz 0 8 leading 0 8 lagging 3 1L N PE 6000 W 6000 W 26 1 A 28 7 A 46002 5000 W 4600 5500 W 20 0 21 7 A 22 2 26 7 A 36801 4000 W 3680 4400 W 16 0 17 4 A 16 0 21 0 A 3000 W 3300 W 13 0 A 15 9 A Protection Integrat...

Page 69: ...ent power of single phase is 4600 VA Certificates For a complete list of certificates visit www peimar com General Data Topology Consumption at Night Consumption at Standby Operating Temperature Range Cooling Method Ambient Humidity Altitude Noise Overvoltage Rating Ingress Protection Mounting Dimensions H x W x D mm Net Weight Warranty Year Transformerless 0 2 W 6 W From 25 C to 60 C 45 C to 60 C...

Page 70: ...s Please refer to the packing list inside the package container DANGER Dangerous to life due to potential fire or electricity shock Do not install the inverter near any inflammable or explosive items This inverter will be directly connected with HIGH VOLTAGE power generation device the installation must be performed by qualified personnel only in compliance with national and local standards and re...

Page 71: ...he inverter tilted forwards sideways horizontally or upside down 3 Install the inverter at eye level for convenience when checking the LCD display and possible maintenance activities 4 When mounting the inverter please consider that disassembly for service work may be required 4 3 2 Installation position Do not expose the inverter to direct solar irradiation as this could cause power derating due ...

Page 72: ...hall be followed for proper ventilation conditions 4 4 Mounting procedure 4 4 1 Mark the positions of the drill holes of the rear panel The mounting position should be marked as shown in Figure 4 3 Figure 4 4 Figure 4 5 Figure 4 2 Minimum clearance Figure 4 3 Dimensions of rear panel of PSI J1000 TL PSI J1500 TL 252 9 211 239 188 265 40 20 20 16 ø 8 30 cm 50 cm 50 cm 30 cm 30 cm ...

Page 73: ...d then place expansion tubes in the holes using a rubber mallet Figure 4 4 Dimensions of rear panel of PSI J2000 TL PSI J2500 TL PSI J3000 TL Figure 4 5 Dimensions of rear panel of PSI J3000 TLM PSI J4000 TLM PSI J5000 TLM PSI J6000 TLM Figure 4 6 Drill holes dimensions of PSI J1000 TL PSI J1500 TL 296 9 283 255 77 5 77 5 92 311 40 20 7 2 7 2 4 ø8 305 289 240 86 43 188 94 ø8 ...

Page 74: ...imensions of PSI J3000 TLM PSI J4000 TLM PSI J5000 TLM PSI J6000 TLM 4 4 3 Mount the screws and the rear panel The panels should be mounted in the mounting position by screws as shown in Figure 4 9 Figure 4 10 Figure 4 11 Figure 4 9 Mount the rear panel of PSI J1000 TL PSI J1500 TL 247 77 59 2 ø8 240 120 ø8 ...

Page 75: ...75 EN Figure 4 10 Mount the rear panel of PSI J2000 TL PSI J2500 TL PSI J3000 TL Figure 4 11 Mount the rear panel of PSI J3000 TLM PSI J4000 TLM PSI J5000 TLM PSI J6000 TLM ...

Page 76: ...4 Make sure that the rear part of the equipment is closely mounted to the rear panel Use the two specific screws to lock the inverter to the rear panel Figure 4 12 Mount PSI J1000 TL PSI J1500 TL Figure 4 13 Mount PSI J2000 TL PSI J2500 TL PSI J3000 TL Figure 4 14 Mount PSI J3000 TLM PSI J4000 TLM PSI J5000 TLM PSI J6000 TLM ...

Page 77: ...shock When power on the equipment should be in conformity with national rules and regulations The direct connection between the converter and high voltage power systems must be operated by qualified technicians in accordance with local and national power grid standards and regulations WARNING When the photovoltaic array is exposed to light it supplies a DC voltage to the inverter NOTICE Electrical...

Page 78: ...l interface of PSI J1000 TL PSI J1500 TL PSI J2000 TL PSI J2500 TL PSI J3000 TL Figure 5 2 Electrical interface of PSI J3000 TLM PSI J4000 TLM PSI J5000 TLM PSI J6000 TLM Table 5 1 Specifications for interface A DC Input B RS 232 Wi Fi Port C AC Plug Terminal D DC Switch ...

Page 79: ...ct the cables Figure 5 3 Thread the cables Cross sectional Area of Cables mm Outside Diameter of the Cables mm 4 0 6 0 4 0 4 2 5 3 Scope Recommended Value 5 3 1 Feed the AC cable through the AC waterproof hole 5 3 3 Secure all parts of theAC connector tightly 5 3 2 Connect the cables according to connection marks of L N and PE ...

Page 80: ...gure 5 6 Connect the inverter Table 5 3 Recommended specifications of DC cables Figure 5 7 Positive connector 5 4 DC side connection Cross sectional Area of Cables mm Outside Diameter of the Cables mm 4 0 6 0 4 0 4 2 5 3 Scope Recommended Value DC connector is made up of the positive connector and the cathode connector Insulated Enclosure Lock Screw ...

Page 81: ...nclosure of the positive and cathode cables with appropriate length Positive Cable L1 L1 L2 8 10mm L2 8 10mm Negative Cable NOTICE Please place the connector separately after unpacking in order to avoid confusion for connection of cables Please connect the positive connector to the positive side of the solar panels and connect the cathode connector to the cathode side of the solar side Be sure to ...

Page 82: ...sure a click should be heard or felt when the contact cable assembly is seated correctly 6 Fasten the lock screws on positive and negative connectors into respondent insulated enclosure and make them tight 7 Connect the positive and cathode connectors into positive and negative DC input terminals of the inverter a click should be heard or felt when the contact cable assembly is seated correctly Co...

Page 83: ...RI Ring Indicator Figure 5 11 Pins of nine serial port cable Table 5 5 Instruction of nine serial port pins 5 5 Communication connection Mirus Unicus e Geminus are equipped with a RS 232 interface 6 5 7 4 8 3 9 2 1 The RS 232 can be connected externally to Wi Fi module For further details please refer to the relative guide attached to the device or downloadable from www peimar com ...

Page 84: ...ght is on when the inverter is powered Red LED ERROR Green LED WORKING The green light is on during normal operation of the device B C D E F The display shows the operational data information and recorded parameters Button Exit Button Enter The red light goes on when an error occurs The red light goes off after errors are resolved DISPLAY Figure 6 1 Human computer interface ...

Page 85: ... inverter allow you to navigate the menu for inquiry information on operation and operating parameters These two buttons can be used repeatedly Table 6 2 Instructions for buttons Figure 6 2 Please set the language Please set the language first Move down the cursor to enter into the sub menu or reduce the setting value Move up the cursor to enter into the superior menu or increase the setting value...

Page 86: ...mware Normal Fault Wait Update Figure 6 4 Count down seconds Grid Connecting Wait 30s Press the ENT button the display will show the Country options to select Pressing the or button move the cursor to select the correct country and press ENT button to confirm the selection Then set date and time Note The configuration of the country of usage must be made at the first start before the inverter star...

Page 87: ...87 EN Note ...

Page 88: ...y 0 00 kWh P ac 21 W Current Error History Errors IP 0 0 0 0 2018 10 30 17 23 State Normal P ac 344 W V grid 227 9 V I grid 1 58 A f grid 50 03 Hz V PV1 170 5 V I PV1 2 36 A V PV2 0 0 V I PV2 0 00 A Temp 28 8 C Set Param Inverter Info Peripheral Selftest Running Info Statistic Info ENT ENT ENT ENT ENT ...

Page 89: ...ce Clear Energy Factory Setting Language Date SN Code Product Code T Today 0 5 h T Total 0 5 h E Today E Month E Year E Total T Today T Total Firmware Ver SN xxxxxxxxxxxxx PC xxxxxxxxxxxxx Machine Type PSI Jxxxx xx UK G83 1 Please Enter Password 1 Australia 2 Austria Error Code 24 No Grid Err M Error Code 24 No Grid Err M 18 10 30 13 20 18 09 30 10 23 ENT ENT ENT ENT ENT ENT ENT ENT ENT ENT ENT EN...

Page 90: ...Param Inverter Info Language Date Language x x English Are you sure to set it Set Completed ENT ENT ENT ENT ENT E today 0 00 kWh P ac 21 W Set Completed Set Param Inverter Info Language Date Language Date Date 2018 10 30 Are you sure to set it ENT ENT ENT ENT ENT Running Info Statistic Info Running Info Statistic Info ...

Page 91: ...Completed ENT ENT ENT E today 0 00 kWh P ac 21 W Running Info Statistic Info Set Param Inverter Info Language Date Are you sure to set it Time Grid Compliance Please Enter Password 1 Australia 2 Austria ENT ENT ENT ENT ENT ENT ENT G83 1 G83 2 13 Switzerlad 14 UK Attention default password 123456 Running Info Statistic Info Set Completed Inverter restart automatically ...

Page 92: ...r Info Language Date Change Password Clear Errors Please Enter Password Please Enter New Password ENT ENT ENT ENT Set Completed Set New Password AS ENT E today 0 00 kWh P ac 21 W ENT Running Info Statistic Info Set Param Inverter Info Language Date Change Password Clear Errors ENT ENT Are you sure to set it Set Completed ENT Please Enter Password ENT ...

Page 93: ...o Language Date Clear Energy Factory Setting Please Enter Password ENT ENT ENT Are you sure to set it Set Completed ENT E today 0 00 kWh P ac 21 W ENT Running Info Statistic Info Set Param Inverter Info Language Date Clear Energy Factory Setting Please Enter Password ENT ENT ENT ENT Set Completed Are you sure to set it Inverter restart automatically ...

Page 94: ...T ENT ENT All test 0 0 result 9 All test 1 Ovp 59 S2 2 Ovp10 59 S1 Peripheral Selftest E Today 0 00 kWh P ac 21 W ENT ENT ENT 1 Ovp 59 S2 Vs230 7V To190ms 1 Ovp 59 S2 Vt264 5V Tt200ms All test 0 0 result Tests passed 6 5 Complete Selftest of the inverter Only when the country selected is Italy 0 21 ...

Page 95: ...l Selftest 1 Ovp 59 S2 2 Ovp10 59 S1 Ovp10 59 S1 0 0 result Ovp10 59 S1 1 1 test 2 Ovp10 59 S1 Please Wait 599s Test passed ENT ENT Running Info Statistic Info Peripheral Selftest 1 Ovp 59 S2 2 Ovp10 59 S1 Ovp 59 S2 0 0 result Ovp 59 S2 1 1 test 1 Ovp 59 S2 Please Wait 599s Test passed ENT ENT ENT ENT ENT 1 Ovp 59 S2 Vt264 5V Tt200ms Vs230 7V To190ms Vo230 2V Pass 2018 10 29 08 00 All test 0 0 res...

Page 96: ...o Running Info Statistic Info Peripheral Selftest Peripheral Selftest 3 Uvp 27 S1 4 Uvp2 27 S2 3 Uvp 27 S1 4 Uvp2 27 S2 Uvp 27 S1 0 0 result Uvp2 27 S2 0 0 result Uvp 27 S1 1 1 test Uvp2 27 S2 1 1 test 3 Uvp 27 S1 Please Wait 599s 4 Uvp2 27 S2 Please Wait 599s Test passed Test passed ENT ENT ENT ENT ENT ENT ENT ENT ...

Page 97: ... Running Info Statistic Info Peripheral Selftest Peripheral Selftest 5 Ofp 81 S1 6 Ofp2 81 S2 5 Ofp 81 S1 6 Ofp2 81 S2 Ofp 81 S1 0 0 result Ofp2 81 S2 0 0 result Ofp 81 S1 1 1 test Ofp2 81 S2 1 1 test 5 Ofp 81 S1 Please Wait 599s 6 Ofp2 81 S2 Please Wait 599s Test passed Test passed ENT ENT ENT ENT ENT ENT ENT ENT ENT ...

Page 98: ...nfo Running Info Statistic Info Peripheral Selftest Peripheral Selftest 7 Ufp 81 S1 8 Ufp2 81 S2 7 Ufp 81 S1 8 Ufp2 81 S2 Ufp 81 S1 0 0 result Ufp2 81 S2 0 0 result Ufp 81 S1 1 1 test Ufp2 81 S2 1 1 test 7 Ufp 81 S1 Please Wait 599s 8 Ufp2 81 S2 Please Wait 599s Test passed Test passed ENT ENT ENT ENT ENT ENT ENT ENT ...

Page 99: ...toring operation The equipment is equipped with a RS 232 interface and the RS 232 interface can be connected to Wi Fi module which can be used in the monitoring of the operation status The equipment can be connected to local internet via a Wi Fi module and the Wi Fi web server which is embedded in the machine following this the operational status of the inverter can be monitored By connecting the ...

Page 100: ...aster High Temperature Master Storer Error Master GFCI Devices Error Master DCI Devices Error Master Current Sensor Master Grid Voltage High Master Grid Voltage Low Master Average voltage of 10 minutes High Master Frequency High Master Error Code 19 Error Code 4 Error Code 24 Error Code 33 Error Code 40 Error Code 5 Error Code 27 Error Code 35 Error Code 41 Error Code 28 Error Code 38 Error Code 5...

Page 101: ... this error occurs frequently please contact your DNO or contact Peimar assistance GFCI Device Error If this error occurs frequently please contact your DNO or contact Peimar assistance DCI Device Error Grid Voltage High Slave Data Consistency of GFCI Slave Grid Voltage Low Slave Frequency High Slave PV2 Voltage High Master Frequency Low Slave No Grid Error Slave PV1 Voltage High Master Lost Commu...

Page 102: ...eimar assistance DCI Error Check the insulation resistance of the positive side and negative side of the solar panel check whether the inverter is in wet environment check the grounding of the inverter If the above mentioned are normal please contact your DNO or contact Peimar assistance GFCI Error Check the insulation resistance of the positive side and negative side of the solar panel check whet...

Page 103: ...mar designer can help you If the above mentioned are normal please contact your DNO or contact Peimar assistance PV Voltage Fault Check the connection of communication cables between control board and display board If the above mentioned are normal please contact your DNO or contact Peimar assistance Lost Communication Table 7 2 Troubleshooting ...

Page 104: ...e from the website www peimar com Chapter 8 Recycling and Disposal This device should not be disposed as residential waste An inverter that has reached the end of its life and is not required is to be returned to your dealer or you must find an approved collection and recycling facility in your area ...

Page 105: ...105 EN Note ...

Page 106: ......

Page 107: ... manual proporciona información sobre cómo instalar manejar y realizar el mantenimiento del producto que ha adquirido así como las pautas de seguridad e instrucciones necesarias para resolver cualquier problema Lea este documento detenidamente y siga las instrucciones para que podamos brindarle nuestro asesoramiento profesional y un servicio de asistencia completo Nuestro compromiso está constante...

Page 108: ... Vista general y dimensiones de los productos 115 3 4 Fichas técnicas MIRUS LINE 116 3 5 Fichas técnicas UNICUS LINE 118 3 6 Fichas técnicas GEMINUS LINE 120 Capítulo 4 Instrucciones para la instalación 122 4 1 Instrucciones de seguridad 122 4 2 Control antes de la instalación 122 4 3 Identificación del modo y de la posición de instalación 123 4 4 Procedimiento de montaje 124 Capítulo 5 Conexión e...

Page 109: ...7 6 3 La pantalla del inversor 140 6 4 Establecer los parámetros generales del inversor 142 6 5 Autotest completo del inversor 146 6 6 Autotest individual del inversor 147 6 7 Operación de control 151 Capítulo 7 Códigos de error y solución de problemas 152 7 1 Código error y descripción 152 7 2 Indicación del error y solución del problema 153 Capítulo 8 Reciclaje y eliminación 156 Capítulo 9 Servi...

Page 110: ... 3 Personal pertinente Únicamente personal cualificado que haya leído y comprendido plenamente todas las normas de seguridad establecidas en este manual puede estar a cargo de realizar la instalación el mantenimiento y la reparación del inversor El personal debe tener conocimiento de que el inversor es un dispositivo de alto voltaje PELIGRO indica una situación peligrosa que de no evitarse provoca...

Page 111: ... red y del generador fotovoltaico Es necesario aguardar al menos cinco minutos para permitir que los condensadores de almacenamiento de energía se descarguen por completo después de que han sido desconectados de la fuente de energía ADVERTENCIA Únicamente personal cualificado puede estar a cargo de realizar la instalación el mantenimiento el reciclaje y la eliminación de los inversores y hacerlo d...

Page 112: ...proveer energía de corriente alterna directamente a la red eléctrica pública No conecte la salida de CA del inversor a ningún dispositivo que no esté conectado a la red de distribución pública 2 2 Explicación de los símbolos VOLTAJE ELÉCTRICO PELIGROSO Este dispositivo está conectado directamente a la red eléctrica pública por lo tanto cualquier trabajo en el inversor debe ser realizado por person...

Page 113: ...de error y su resolución TOMA A TIERRA Punto de conexión del conductor de protección de la toma a tierra Marca CE Los dispositivos con la marca CE respetan los requisitos básicos de la Directiva de Baja Tensión y la Directiva de Compatibilidad Electromagnética ROHS Restriction of Hazardous Substances Directive SIN TRANSFORMADOR Este inversor no tiene transformador de aislamiento Este dispositivo N...

Page 114: ... red pública de modo que pueda ser utilizada para satisfacer la demanda de electricidad del hogar o negocio y enviar el excedente a la red La Tabla 3 1 muestra el esquema estructural del sistema de aplicación típico de los inversores PSI J Tabla 3 1 Diagrama de configuración Silicio monocristalino o policristalino y módulos fotovoltaicos con una película delgada con protección de nivel II y sin ne...

Page 115: ...l inversor 3 3 Vista general y dimensiones de los productos Las dimensiones de los productos se muestran en la Figura 3 2 Figura 3 2 Dimensiones de los productos de la serie Mirus Unicus Geminus PSI JXXXX TL PSI JXXXX TLM 305 mm 120 354 mm SERIE UNICUS PSI J2000 TL PSI J2500 TL PSI J3000 TL 355 mm 150 162 mm 454 PSI J3000 TLM PSI J4000 TLM PSI J5000 TLM PSI J6000 TLM SERIE GEMINUS 260 mm 120 mm 31...

Page 116: ...tencia nominal CA Potencia máxima CA Corriente nominal CA Corriente máxima CA Voltaje nominal CA Rango Frecuencia de red Rango Factor de potencia cos φ Distorsión armónica total Conexión Salida CA 220 V 230 V 240 V 180 V 280 V 50 Hz 60 Hz 5 Hz 0 99 completamente cargado 3 Monofásica 1L N PE 1500 W 1650 W 6 5 A 7 9 A 1000 W 1100 W 4 3 A 5 3 A Protección Protección contra sobretensiones Control de a...

Page 117: ...ransformador 0 2 W 6 W De 25 C a 60 C 45 C a 60 C con derating Convección natural De 0 a 100 sin condensación Hasta 2000 m sin derating 15 dBA II entrada CC III salida CA IP65 instalación interior y exterior Soporte de pared 315 x 260 x 120 5 6 kg 5 estándar 10 opcional Topología Consumo nocturno Consumo en espera Rango de temp en funcionamiento Método de enfriamiento Humedad ambiente Altitud Ruid...

Page 118: ...go de voltaje MPPT Voltaje nominal CC Voltaje de encendido Voltaje mínimo CC Corriente de entrada máxima CC Cantidad de entradas de CC para cada MPPT Cantidad de MPPT Seccionador de CC Potencia nominal CA Potencia máxima CA Corriente nominal CA Corriente máxima CA Voltaje nominal CA Rango Frecuencia de red Rango Factor de potencia cos φ Distorsión armónica total Conexión Protección Protección cont...

Page 119: ...g Convección natural De 0 a 100 sin condensación Hasta 2000 m sin derating 15 dBA II entrada CC III salida CA IP65 instalación interior y exterior Soporte de pared 354 x 305 x 120 5 estándar 10 opcional 8 4 kg 8 3 kg 7 8 kg Topología Consumo nocturno Consumo en espera Rango de temp en funcionamiento Método de enfriamiento Humedad ambiente Altitud Ruido Clasificación de sobretensión Grado de protec...

Page 120: ...3 0 A 15 9 A 3 6 Fichas técnicas GEMINUS LINE Potencia máxima CC Voltaje máximo CC Rango de voltaje MPPT Voltaje nominal CC Voltaje de encendido Voltaje mínimo CC Corriente de entrada máxima CC Cantidad de entradas de CC para cada MPPT Cantidad de MPPT Seccionador de CC Potencia nominal CA Potencia máxima CA Corriente nominal CA Corriente máxima CA Voltaje nominal CA Rango Frecuencia de red Rango ...

Page 121: ...talación interior y exterior Soporte de pared 5 estándar 10 opcional 454 x 355 x 162 15 8 kg 454 x 355 x 150 14 8 kg Información general Topología Consumo nocturno Consumo en espera Rango de temp en funcionamiento Método de enfriamiento Humedad ambiente Altitud Ruido Clasificación de sobretensión Grado de protección Montaje Dimensiones H x W x D mm Peso neto Garantía Año 1 Cumplir con el estándar ...

Page 122: ...de piezas contenida en el paquete PELIGRO Peligro de muerte debido a incendio o descarga eléctrica No instale el inversor cerca de objetos inflamables o explosivos Este inversor se debe conectar directamente a un generador eléctrico de ALTO VOLTAJE Su instalación debe ser llevada a cabo exclusivamente por personal cualificado de acuerdo con las normas y reglamentos nacionales y locales AVISO Este ...

Page 123: ...cia los lados en posición horizontal o invertida 3 Instale el inversor a la altura de la vista para facilitar la visualización de la pantalla y las posibles actividades de mantenimiento 4 Instale el inversor previendo la posibilidad de desmontarlo para trabajos de mantenimiento 4 3 2 Posición de instalación No exponga el inversor a la luz solar directa Esto podría causar una reducción en la potenc...

Page 124: ...de seguridad mínimas que se indican en la Figura 4 2 4 4 Procedimiento de montaje 4 4 1Marquelospuntosdeperforaciónparamontarelsoportedeanclaje La posición de montaje debe estar marcada como se muestra en las Figura 4 3 Figura 4 4 y Figura 4 5 Figura 4 2 Distancias mínimas Figura 4 3 Dimensiones del soporte de PSI J1000 TL PSI J1500 TL 252 9 211 239 188 265 40 20 20 16 ø 8 30 cm 50 cm 50 cm 30 cm ...

Page 125: ...a 4 6 Figura 4 7 Figura 4 8 y luego inserte los tacos de fijación con un martillo de goma Figura 4 4 Dimensiones del soporte de PSI J2000 TL PSI J2000 TL PSI J2500 TL Figura 4 5 Dimensiones del soporte de PSI J3000 TLM PSI J4000 TLM PSI J3000 TLM PSI J4000 TLM Figura 4 6 Dimensiones de los orificios para PSI J1000 TL PSI J1500 TL 296 9 283 255 77 5 77 5 92 311 40 20 7 2 7 2 4 ø8 305 289 240 86 43 ...

Page 126: ...PSI J3000 TLM PSI J4000 TLM PSI J5000 TLM PSI J6000 TLM 4 4 3 Coloque los tornillos y monte el soporte de anclaje Se deben fijar los soportes en la posición de montaje utilizando los tornillos como se muestra en las Figura 4 9 Figura 4 10 y Figura 4 11 Figura 4 9 Montaje del soporte de PSI J1000 TL PSI J1500 TL 247 77 59 2 ø8 240 120 ø8 ...

Page 127: ...127 ES Figura 4 10 Montaje del soporte de PSI J2000 TL PSI J2500 TL PSI J3000 TL Figura 4 11 Montaje del soporte de PSI J3000 TLM PSI J4000 TLM PSI J5000 TLM PSI J6000 TLM ...

Page 128: ...te posterior del dispositivo esté montada en contacto con el soporte Utilizar los dos tornillos apropiados para bloquear el inversor al soporte Figura 4 12 Montaje del inversor PSI J1000 TL PSI J1500 TL Figura 4 13 Montaje del inversor PSI J2000 TL PSI J2500 TL PSI J3000 TL Figura 4 14 Montaje del inversor PSI J3000 TLM PSI J4000 TLM PSI J5000 TLM PSI J6000 TLM ...

Page 129: ...encendido el dispositivo debe cumplir con las normas y reglamentos nacionales Técnicos cualificados deben realizar la conexión entre el convertidor y la red de distribución eléctrica y hacerlo según las normas y reglamentos nacionales y locales sobre redes eléctricas ADVERTENCIA Cuando el sistema fotovoltaico está expuesto a la luz suministra una tensión de CC al inversor NOTICE La conexión eléctr...

Page 130: ... conexión de PSI J1000 TL PSI J1500 TL PSI J2000 TL PSI J2500 TL PSI J3000 TL Figura 5 2 Entradas de conexión de PSI J3000 TLM PSI J4000 TLM PSI J5000 TLM PSI J6000 TLM Tabla 5 1 Entradas de conexión A Entrada CC B RS 232 Puerto Wi Fi C Toma de conexión de CA D Seccionador de CC ...

Page 131: ...de los cables Figura 5 3 Inserte el cable Sección de cable mm Diámetro exterior de cable mm 4 0 6 0 4 0 4 2 5 3 Mínimo máximo Valor recomendado 5 3 1 Inserte el cable de CA en el prensacable impermeable 5 3 3 Sujete firmemente todos los componentes del conector de CA 5 3 2 Conecte los cables de acuerdo con las marcas de conexión de L N y PE ...

Page 132: ...á completada Figura 5 6 Conexión del inversor Tabla 5 3 Características recomendadas para cables de CC Figura 5 7 Conector positivo 5 4 Conexión lateral CC Sección de cable mm Diámetro exterior de cable mm 4 0 6 0 4 0 4 2 5 3 Mínimo máximo Valor recomendado La conexión de CC está conformada por el conector positivo y el conector negativo Cubierta aislante Tornillos de bloqueo ...

Page 133: ...uitar la funda aislante de los cables positivo y negativo para la longitud adecuada Cable Positive L1 L1 L2 8 10mm L2 8 10mm Cable Negative AVISO Coloque el conector por separado después de desembalarlo para evitar errores de conexión del cable Conecte el conector positivo al polo positivo de los paneles solares y el conector negativo al polo negativo de los paneles solares Cerciórese de que la co...

Page 134: ...s fundas aislantes Se escuchará un clic cuando el cable engarzado esté correctamente colocado 6 Cierre los tornillos de bloqueo de los conectores positivo y negativo de la funda aislante correspondiente y apriételos 7 Conecte los conectores positivo y negativo a los respectivos terminales de entrada de CC del inversor Se escuchará un clic cuando los conectores estén correctamente conectados Puerto...

Page 135: ...ura 5 11 Puerto serie de 9 pines Tabla 5 5 Instrucciones de cableado del puerto serie de 9 pines 5 5 Conexión del interfaz de comunicación Los inversor Mirus Unicus e Geminus están equipados con un interfaz RS 232 6 5 7 4 8 3 9 2 1 RS 232 puede conectarse externamente al módulo Wi Fi Para obtener más información consulte la guía pertinente adjunta al dispositivo o descargable a través de www peima...

Page 136: ...uz amarilla está encendida cuando el inversor está encendido LED rojo ERROR LED verde FUNCIONAMIENTO La luz verde está encendida durante el funcionamiento normal del dispositivo B C D E F La pantalla muestra los datos operativos la información y los parámetros registrados Tecla Salida Tecla Enter La luz roja se encenderá cuando ocurra un error La luz roja se apagará después de resolver los errores...

Page 137: ...ra ingresar al menú secundario o reduce el valor de configuración Mueve el cursor hacia arriba para ingresar al menú superior o reduce el valor de configuración Regresa al menú anterior o cancela el comando actual Entra en el menú secundario o confirma el mando Pulsar menos de 1 segundo Pulsar menos de 1 segundo Pulsar más de 1 segundo Pulsar más de 1 segundo Figura 6 3 Ingresar el país Seleccione...

Page 138: ...era Actualización Figura 6 4 Cuenta atrás en segundos Conectando red espere 30s Pulse la tecla ENT la pantalla mostrará las opciones de país para seleccionar Pulsar las teclas o mover el cursor para seleccionar el país correcto y después pulsar la tecla ENT para confirmar la selección Después configurar fecha y ora Nota Se debe establecer la configuración del país de uso antes de que el inversor c...

Page 139: ...139 ES Notas ...

Page 140: ...hoy 0 00 kWh P ca 21 W Error actual Historial err IP 0 0 0 0 2018 10 30 17 23 Estado Normal P ca 344 W V ca 227 9 V I ca 1 58 A f ca 50 03 Hz V PV1 170 5 V I PV1 2 36 A V PV2 0 0 V I PV2 0 00 A Temp 28 8 C Programar param Info inversor Periferica Autotest Valor actual Estadistica ENT ENT ENT ENT ENT ...

Page 141: ...Standard de red Restab energia Ajustes fabrica Idioma Fecha Número de serie Codigo producto T Hoy 0 5 h T Total 0 5 h E Hoy E Mes E Año E Total T Hoy T Total Vers firmware Modelo inversor PSI Jxxxx xx España RD1699 Insertar Clave 1 Australia 2 Austria Error 24 Error 24 18 10 30 13 20 18 09 30 10 23 ENT ENT ENT ENT ENT ENT ENT ENT ENT ENT ENT ENT ENT ENT ENT ENT ENT ENT ENT SN xxxxxxxxxxxxx PC xxxx...

Page 142: ... 21 W Programar param Info inversor Idioma Fecha Idioma x x Español Quiere confirmar Prog Completa ENT ENT ENT ENT ENT E hoy 0 00 kWh P ca 21 W Prog Completa Programar param Info inversor Idioma Fecha Idioma Fecha Fecha 2018 10 30 Quiere confirmar ENT ENT ENT ENT ENT Valor actual Estadistica Valor actual Estadistica ...

Page 143: ...ar Prog Completa ENT ENT ENT E hoy 0 00 kWh P ca 21 W Valor actual Estadistica Programar param Info inversor Idioma Fecha Hora Standard de red Insertar Clave 1 Australia 2 Austria ENT ENT ENT ENT ENT Quiere confirmar 27 NuevaZelanda 28 España Advertencia de contraseña por defecto 123456 Valor actual Estadistica Prog Completa ENT El inversor se reinicia automaticámente ...

Page 144: ...rores ENT ENT ENT Quiere confirmar Prog Completa ENT Insertar Clave ENT E hoy 0 00 kWh P ca 21 W Programar param Info inversor Idioma Fecha Cambio de clave Borrar errores Insertar Clave Ingrese clave nueva ENT ENT ENT ENT ENT Prog Completa Programe clave nueva ENT Advertencia de contraseña por defecto 123456 Valor actual Estadistica Valor actual Estadistica ...

Page 145: ... Clave ENT ENT ENT ENT Quiere confirmar Prog Completa ENT E hoy 0 00 kWh P ca 21 W Programar param Info inversor Idioma Fecha Restab energia Ajustes fabrica Insertar Clave ENT ENT ENT ENT ENT Prog Completa Quiere confirmar Advertencia de contraseña por defecto 123456 Valor actual Estadistica Valor actual Estadistica El inversor se reinicia automaticámente ...

Page 146: ... 0 0 resultado 9 Todos tests 1 Ovp 59 S2 2 Ovp10 59 S1 Periferica Autotest Valor actual Estadistica ENT ENT ENT 1 Ovp 59 S2 Vs230 7V To190ms 1 Ovp 59 S2 Vt264 5V Tt200ms Todos tests 0 0 resultado Prueba pasada 6 5 Autotest completo del inversor Solo cuando el país seleccionado es Italia 0 21 2018 10 29 08 00 ...

Page 147: ...ca Autotest 1 Ovp 59 S2 2 Ovp10 59 S1 Ovp10 59 S1 0 0 resultado Ovp10 59 S1 1 1 test 2 Ovp10 59 S1 Espere 599s Prueba pasada ENT ENT Valor actual Estadistica Periferica Autotest 1 Ovp 59 S2 2 Ovp10 59 S1 Ovp 59 S2 0 0 resultado Ovp 59 S2 1 1 test 1 Ovp 59 S2 Espere 599s Prueba pasada ENT ENT ENT ENT ENT 1 Ovp 59 S2 Vt264 5V Tt200ms Vs230 7V To190ms Vo230 2V Pasar 2018 10 29 08 00 Todos tests 1 1 r...

Page 148: ...al Estadistica Periferica Autotest Periferica Autotest 3 Uvp 27 S1 4 Uvp2 27 S2 3 Uvp 27 S1 4 Uvp2 27 S2 Uvp 27 S1 0 0 resultado Uvp2 27 S2 0 0 resultado Uvp 27 S1 1 1 test Uvp2 27 S2 1 1 test 3 Uvp 27 S1 Espere 599s 4 Uvp2 27 S2 Espere 599s Prueba pasada Prueba pasada ENT ENT ENT ENT ENT ENT ENT ENT ...

Page 149: ...ual Estadistica Periferica Autotest Periferica Autotest 5 Ofp 81 S1 6 Ofp2 81 S2 5 Ofp 81 S1 6 Ofp2 81 S2 Ofp 81 S1 0 0 resultado Ofp2 81 S2 0 0 resultado Ofp 81 S1 1 1 test Ofp2 81 S2 1 1 test 5 Ofp 81 S1 Espere 599s 6 Ofp2 81 S2 Espere 599s Prueba pasada Prueba pasada ENT ENT ENT ENT ENT ENT ENT ENT ENT ...

Page 150: ...ctual Estadistica Periferica Autotest Periferica Autotest 7 Ufp 81 S1 8 Ufp2 81 S2 7 Ufp 81 S1 8 Ufp2 81 S2 Ufp 81 S1 0 0 resultado Ufp2 81 S2 0 0 resultado Ufp 81 S1 1 1 test Ufp2 81 S2 1 1 test 7 Ufp 81 S1 Espere 599s 8 Ufp2 81 S2 Espere 599s Prueba pasada Prueba pasada ENT ENT ENT ENT ENT ENT ENT ENT ...

Page 151: ...ificar de una vez 6 7 Operación de control El dispositivo está equipado con una interfaz RS 232 que se puede conectar a un módulo Wi Fi que se puede usar para supervisar el estado operativo El dispositivo se puede conectar a la Internet local mediante un módulo Wi Fi y el servidor web integrado en el dispositivo De esta forma se puede controlar el estado de funcionamiento del inversor Al conectars...

Page 152: ...aster Error de coherencia de los datos de voltaje Slave Error de relé Master Alta temperatura Master Error de memoria EEPROM Master Error de dispositivos GFCI Master Error de dispositivos DCI Master Error de sensor de corriente Master Voltaje de red alto Master Voltaje de red bajo Master Tensión media de 10 minutos alta Master Frecuencia alta Master Error 19 Error 04 Error 24 Error 33 Error 40 Err...

Page 153: ...ue el disipador de calor no esté obstruido y que la temperatura del inversor no esté demasiado alta o baja Si las condiciones anteriores son correctas póngase en contacto con su distribuidor o con la asistencia técnica de Peimar Alta temperatura Si este error ocurre con frecuencia comuníquese con su distribuidor o con el servicio técnico de Peimar Error de memoria EEPROM Si este error ocurre con f...

Page 154: ...a Si este error está siempre presente comuníquese con su distribuidor o con el servicio técnico de Peimar Error DCI Compruebe la resistencia de aislamiento del lado positivo y el lado negativo de los paneles solares Verifique que el inversor no esté en un ambiente húmedo Compruebe la correcta puesta a tierra del inversor Si las condiciones indicadas son correctas póngase en contacto con su distrib...

Page 155: ...e Peimar Corriente PV elevada Compruebe los ajustes de los paneles solares Los técnicos de Peimar pueden ayudarle Si las condiciones indicadas son correctas póngase en contacto con su distribuidor o con la asistencia técnica de Peimar Error de voltaje PV Verifique la conexión de los cables de comunicación entre la placa de control y la de la pantalla Si las condiciones indicadas son correctas póng...

Page 156: ...gable desde el sitio web www peimar com Capítulo 8 Reciclaje y eliminación Este dispositivo no debe ser eliminado como residuos urbanos Cuando un inversor ha llegado al final de su vida útil y ya no se puede utilizar debe devolverse a su distribuidor o eliminarse en un centro autorizado de recolección y reciclaje en su área ...

Page 157: ...157 ES Notas ...

Page 158: ......

Page 159: ......

Page 160: ...info peimar com www peimar com Version 01 2019 ...

Reviews: