structure & DescriPtiOn

APPLicAtiOn

The PHC voltage supply belongs to the PEHA PHC system. It 

is designed for supplying the PHC system with 24V DC/ 1.5A. 

The modular sockets and the module bus terminal (optional) 

are for data connection and voltage supply to further modules.

N

N

L

L

– +

24V A

B 0V

 Bus In

 Bus Out

Status

220-240 V AC 

50-60 Hz

~

24 V DC
1,5 A

PHC System

942 SPV

S

Status LED

Module bus terminal  

Operating voltage

220-240V~ / 50-60Hz

Voltage supply setting

21-26V DC (standard = 24V DC)

note:

 Read through the operating instructions care-

fully before putting the device into service!

LeD DisPLAys

 status LeD

Off

No operating voltage

Green

Module ready (operating mode)

sAfety

Vorsicht! Erhöhte
Strahlung

Vorsicht! Kontamination

Vorsicht! Kontamination

Vorsicht, Gefahr durch
Abquetschen

Vorsicht, Gefahr durch
Abschneiden

Vorsicht, Gefahr durch
Abstürzen

Vorsicht, Gefahr durch
ätzende Stoffe

Vorsicht, Gefahr durch
elektrischen Strom

Vorsicht, Gefahr durch
elektrischen Strom

Vorsicht, Gefahr durch
elektromagnetische
Strahlung

Vorsicht, Gefahr durch
explosionsgefährliche
Stoffe

Vorsicht, Gefahr durch
feuergefährliche Stoffe

Vorsicht, Gefahr durch
giftige Stoffe

Vorsicht, Gefahr durch
heiße Oberfläche

Vorsicht, Gefahr durch
Laserstrahlung

Vorsicht, Gefahr durch
Radioaktivität

Vorsicht, Gefahr durch
Rutschen

Vorsicht, Gefahr durch
Stolpern

Vorsicht, Gefahr durch
Verwickeln

Vorsicht, Warnung vor
einer Gefahrstelle

Vorsichtig verschieben!
- veraltet -

Während der
Schweißarbeiten,
Arbeitsstelle beobachten

Wandbrände nicht von
oben löschen

Wandbrände von unten
nach oben löschen

Wandhydrant

Wandhydrant (2.
Vorschlag)

Wandhydrant, mit Angabe
des Anschlusses

Wareneingang -
Freigegeben

Wareneingang - Gesperrt

Wärmeabzugseinrichtung

cAutiOn! Danger of electrical shock! 

the housing contains current-carrying components. 

contact  can lead to personal injury! All work on 

the mains network and the device may only be per-

formed by an authorised electrician.

• Disconnect power supply from the device.

• Secure the device against being powered on again.

• Check that the device is powered off.

• Close the housing securely before applying power.

This device is only intended to be used for its stated appli-

cation. Unauthorised conversions, modifications or changes 

are not permissible! This device may not be used in conjunc-

tion  with  other  devices  whose  operation  could  present  a 

hazard to people, animals or property.

the following must be observed:

• Prevailing statutes, standards and regulations.

• State-of-the-art technology at the time of installation.

• The device’s operating instructions.

• Operating instructions can only cite general stipulations. 

  These are to be viewed in the context of a specific system.

technicAL infOrMAtiOn

Operating voltage

(terminal n, L)

220-240 V~ ±10 % /50-60 Hz

Own consumption

Standby = less than 0.5 W

Power supply

Phc-system

Nominal 24V DC (SELV)

(adjustable 21-26V DC)

Output current

1.5A

fuse

Automatic circuit breaker 

(max. 16A)

Data connection

(Phc bus)

1 modular socket „OUT“

1 modular socket „IN“

1 module bus terminal (optional)

Ambient temperature

0 to +40 °C

storage temperature

-20 to +85 °C

screw terminals

max. 2 x 1.5  mm²

Test specifications

 

EN 61558

Certifications

KEMA/KEUR ; CE

Protection level

IP20

Dimensions

Width =  38 mm (2TE)

Height  =  55 mm

MOunting & instALLAtiOn

important installation information !

Installation and commissioning may only be performed by 

an authorised electrician. Mains power (220-240V~/50-60 

Hz) to electrical equipment must be switched off during 

installation. Applicable laws and standards of the country 

in which the device is operated must be observed! 
The module is designed for mounting on a 35mm top hat 

rail acc. EN 50022 in in-/on-wall distribution housing with 

screwed cover. The devices can be mounted directly next 

to each other.

220-240V~ / 50-60hz

F

N L

N

N

L

L

– +

24V A

B 0V

 Bus In

 Bus Out

Status

220-240 V AC 

50-60 Hz

~

24 V DC
1,5 A

PHC System

942 SPV

S

• Install the PHC module in a suitable location.

• Install the device as shown in wiring diagram.

• Protect supply line at terminal L with circuit breaker 

  (F = 16 A)! 

• Switch on electrical system.

Phc MODuLe bus

notes

– Do not lay the bus line parallel to the consumer and 

  mains cables!

– Observe the maximum cable length (1000 m)!

– Switch off power supply before connecting or disconnect-

  ing bus line.

– The module can be positioned anywhere in the data line.

– A PHC bus line of 30 cm length is included.

– Caution!! Do not apply any mains voltage 

  (230 V~ /50 Hz) to the module bus terminals!

– Make sure the poles are correct (24V, A, B, 0V)!

MODuLAr sOcKet in AnD Out

The  OUT  socket  and  bus  line  serve 

as  the  data  connection  between 

the power supply module and other 

modules.
The  connection  also  supplies  the 

voltage (24 V DC) to the modules.
If an additional voltage supply needs 

to be connected, it is connected to 

the end of the bus line via the IN socket. The data telegrams 

of  the  PHC  system  are  then  forwarded  via  the  “IN”  and 

“OUT” sockets.
The voltage supply can be used as a bus distributor. The bus 

line is laid in a separate distribution and connected to the IN 

socket or module bus terminal.

MODuLe bus terMinAL

The module bus terminal is 

used to route the bus line in 

separate distributions. A JY(ST)

Y cable with 2x 2x 0.8 mm Ø is 

normally used as a bus line.

Caution!!

 If there is a connection between module 

bus terminals with voltage supplies, the 24V line 

must  not  be  connected,  since  compensating  cur-

rents can otherwise flow.

generAL infOrMAtiOn

DisPOsAL Of the DeVice

Do not dispose of old devices in the household 

waste! The device must be disposed of in compli-

ance with the laws and standards of the country 

in which it is operated! 

The device contains electrical components that must be dis-

posed of as electronics waste. The enclosure is made from 

recyclable plastic.

wArrAnty cOnDitiOns

These operating instructions are an integral part of both the 

device and our terms of warranty. They must be handed over 

to the user. The technical design of the appliance is subject 

to  change  without  prior  notification. 

PehA

 products are 

manufactured  and  quality-checked  with  the  latest  techno-

logy  according  to  applicable  national  and  international  re-

gulations. Nevertheless, if a product should exhibit a defect, 

PehA

 warrants to make remedy as follows (regardless of any 

claims against the dealer to which the end user may be en-

titled as a result of the sales transaction):
In  the  event  of  a  justified  and  properly  established  claim, 

PehA

 shall exercise its prerogative to either repair or replace 

the  defective  device.  Further  claims  or  liability  for  conse-

quential damage are explicitly excluded. A justifiable defici-

ency is deemed to exist if the device exhibits a structural, 

manufacturing, or material defect that makes it unusable or 

substantially impairs its utility at the time it is turned over to 

the end user. The warranty does not apply to natural wear, 

improper usage, incorrect connection, device tampering or 

the effects of external influences. The warranty period is 24 

months from the date of purchase by the end user from a 

dealer and ends not later than 36 months after the device’s 

date of manufacture. German law shall be applicable for the 

settlement of warranty claims.

cOntAct

Telephone: ......................+49 (0)2351 185-0

Fax: .................................+49 (0)2351 27666

Internet: .........................www.peha.de

E-Mail: [email protected]

I1 I1 O1

I2 I2

O2

I3 I3 O3

I4 I4

O4

L

N

10A μ

10A μ

10A μ

LRN/CLR

Function

Mode

6

1

0

2

3

4

5

7

8

9

6

1

0

2

3

4

5

7

8

9

24V

A

B

0V

EC Modular System 

454 FU-SPV 4REG

1

2

3

4

100-240 V AC 

50-60 Hz

~

24 V DC
0,3 A

4 x 10A/240V AC

 

μ

 

(I

N

max 4x10A / I

M

 

max 4x3A)

channel

Status

on/off

IN

OUT

N

N

L

L

– +

24V A

B 0V

 Bus In

 Bus Out

Status

220-240 V AC 

50-60 Hz

~

24 V DC
1,5 A

PHC System

942 SPV

S

PEHA Elektro GmbH & Co. KG

Postfach 1727 • D-58467 Lüdenscheid • Internet: www.peha.de

 elektro gmbh & co. Kg

942 sPV

Phc Power supply

installation & operating instructions

GB

Summary of Contents for 942 SPV

Page 1: ... System 942 SPV S PHC Modul an geeigneter Stelle montieren Installation des Geräts nach Anschlussbild vornehmen Versorgungsleitung an Klemme L mit Sicherungsautomat F 16 A absichern Elektrische Anlage einschalten PHC Modulbus Hinweise Die Busleitung nicht parallel zu Verbraucher u Netz leitungen verlegen Die maximale Leitungslänge 1000 m beachten Vor Anschluss oder Trennung der Busleitung Spannung...

Page 2: ...A PHC System 942 SPV S Install the PHC module in a suitable location Install the device as shown in wiring diagram Protect supply line at terminal L with circuit breaker F 16 A Switch on electrical system PHC Module bus Notes Do not lay the bus line parallel to the consumer and mains cables Observe the maximum cable length 1000 m Switch off power supply before connecting or disconnect ing bus line...

Page 3: ...atus 220 240 V AC 50 60 Hz 24 V DC 1 5 A PHC System 942 SPV S Monteer de PHC module op een geschikte plaats Voer de installatie van het apparaat uit volgens aansluit schema Voedingskabel op klem L met zekeringsautomaat F 16 A afzekeren Schakel de elektrische installatie in PHC MODULAIRE BUS Opmerking Leg de buskabel niet parallel aan verbruikers en netkabels Neem de maximale kabellengte 1000 m in ...

Page 4: ... 24V A B 0V Bus In Bus Out Status 220 240 V AC 50 60 Hz 24 V DC 1 5 A PHC System 942 SPV S Monter le module du PHC à l emplacement souhaité Procéder à l installation de l appareil conformément au schéma des connexions Protéger la ligne d alimentation à la borne L avec le coupe circuit automatique F 16 A Mettre l installation électrique sous tension MODULBUS DU PHC Remarque Ne pas poser la ligne Bu...

Reviews: