background image

9/12/2017 

                   Ultimate Powerbox 

 

A smart function exists in the controller’s firmware: The controller can consult the environmental readings of 

the 

dew point and automatically adjust power of the Dew Heaters. This functionality can be switched on / off from the 
software. 

Please notice: Dew heater outputs are suitable for a flat panel also. 

Voltage type 

Port 

12V DC 

 PWM - Duty Cycle % 

RCA Female Jack / 6 Amps Each 

BUILT IN POWER SENSORS 

Each output (4 x 12V + 2 x Dew Heaters) has an individual current meter. Smart Mosfets are capable to diagnose the 
power consumption of each port and provide protection against overload, over temperature and short circuit.  

A DC voltmeter is installed after controller’s power input.

 (Measures 5 

 15 Volts) 

A current meter is installed after controller’s power input.

 (Measures 0 

 30 Amps) 

STEPPER MOTOR CONTROLLER 

A stepper motor controller will move your focuser with absolute positioning. Backlash compensation is implemented 
in the firmware and can be enabled, tuned or disabled from the supplied software. An ASCOM6 focuser driver is 
available. 

Controller can drive 

unipolar

 stepper motors. Can support max 1.6 Amps (

0.8 Amp per phase

). An auto-recovery 

PTC fuse is installed inside the controller to avoid any overcurrent issue with the connected stepper motors. 

An RJ12 connector is located at the back of the Ultimate Powerbox. Pinout can be seen at the following table: 

UNIPOLAR STEPPER MOTOR (RJ12) CONNECTOR 

PIN 1 

12V DC 

PIN 2 

12V DC 

PIN 3 

COIL 1+ 

PIN 4 

COIL 1- 

PIN 5 

COIL 2+ 

PIN 6 

COIL 2- 

ENVIRONMENTAL SENSOR 

The probe is an external temperature / humidity / dew point measurement device which is attached to the 
controller. It comes with length of 1m cable. Probe measures: 

Summary of Contents for ULTIMATE POWERBOX

Page 1: ...ULTIMATE POWERBOX PRODUCT MANUAL BY PEGASUS ASTRO COMPANY ADDRESS VERSION 1 1 SEPTEMBER 12 2017...

Page 2: ...movements of the mount and the instrument only the main power cord and one USB data cord comes to the Ultimate Powerbox from which branch off the other cables powering all devices CONTROLLER CARE Con...

Page 3: ...For your observatory needs you might need 10 15Amps of current Unit has been designed with reverse polarity protection If you accidentally reverse the power source polarity the unit will cut the power...

Page 4: ...ce there is no option to selectively switch a port on off All ports switch ON OFF globally DATA CONNECTIVITY A USB2 Type B port at the back of the unit accepts the USB cable for PC connection A type B...

Page 5: ...s installed after controller s power input Measures 0 30 Amps STEPPER MOTOR CONTROLLER A stepper motor controller will move your focuser with absolute positioning Backlash compensation is implemented...

Page 6: ...e led indicated the status of the device The led can be turned on off from the software at your demand Permanently Light Device is up and running Flashing Light 4 times every 4 sec Device entered to f...

Page 7: ...18 cable Make also sure that you do not exceed 3m to reduce voltage drops I would like to use the Ultimate Powerbox to my remote observatory What if the device freezes for some reason We have good new...

Page 8: ...rade for future features or bug fixes Why don t you place a mini PC inside the Ultimate Powerbox We really don t support this idea Why to buy something and pay noticeable amount of money for a mini PC...

Reviews: