Installation to Wood Stud Wall
NOTE: This step is for mounting enclosure assembly (A) fl ush against supporting surface. For use with
mount, follow instructions provided with wall mount.
Use a stud fi nder to locate the edges of the studs and draw a vertical line down each stud’s center. Place
enclosure assembly (
A
) on wall as a template,
level and mark the center of the six mounting holes. Make sure
that the mounting holes are on the stud centerlines. Drill six 5/32" (4 mm) dia. holes 2.5" (64 mm) deep. Make
sure that the
enclosure
is level and secure it using six 2.5" wood screws (
C
) and six washers (
E
) as shown in
fi gure 3.1.
NOTE:
If cord cover plate assembly (
K
) is used on the rear of the enclosure, you may use the 1/2" spacer (
M
)
between enclosure assembly and wall surface.
• DO NOT lift more weight than you can handle. Always use an assistant or mechanical lifting equipment to safely lift
and position enclosure assembly (
A
).
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that the enclosure assembly is fi rmly attached, but do not overtighten. Overtightening can
damage the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lbs. (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder
is highly recommended.