StreetSmart Pre-Terminated FDH Cabinet

Installation Manual 

 ______________________________________________________

Manual 021814 REV A - Jan 2021

Summary of Contents for StreetSmart Pre-Assigned FDH

Page 1: ...StreetSmart Pre Terminated FDH Cabinet Installation Manual _______________________________________________________ Manual 021814 REV A Jan 2021 ...

Page 2: ...___________________________________________________ Manual 021814 REV A Jan 2021 Table of Contents Application 3 Description 3 Technical Specifications 3 Mounting Base to Vault Lid 4 Mounting Cabinet to Base 6 Pole Mount Installation 7 Pre Loaded Splitters 10 Connector Cleaning Procedure 11 Standard Warranty 16 Proprietary Notice 17 Technical Support 17 ...

Page 3: ...t Pre Assigned FDH PON Cabinet provides an interconnect environment from the feeder network through the passive optical splitter to the distribution network Designed for rapid PON Network deployments these cabinets provide a single distribution point to deploy FTTH in large scale MDU s urban or dense neighbor hoods Pre Assigned WaveSmart High Density 1 x 32 Splitters are loaded into the cabinet wi...

Page 4: ...______________________________________________ Manual 021814 REV A Jan 2021 Mounting Base to Vault Lid 1 2 3 Remove the access door from the back of the cabi net base with a 7 16 socket or can wrench Remove the nuts from the threaded studs holding the cabinet to the base and lift the cabinet from the base Place the cabinet base over the hole in the vault lid ...

Page 5: ...ield com techsupport clfd net Manual 021814 REV A Jan 2021 4 5 6 Place the rectangular washer plates over the round cutouts in the cabinet base Insert the J bolts through the base of the rectangular washer plates ensuring that the J hook is hooked under a rib of the vault lid underneath Using the washers lock washers and nuts provided secure the cabinet vase to the vault lid ...

Page 6: ..._______ Manual 021814 REV A Jan 2021 Mounting Cabinet to Base 1 2 3 Feed the cables through the cabinet base and vault lid as you lower the cabinet onto the base Carefully align all the threaded studs on the bottom of the cabinet with the holes in the top of the base as you seat it into place Using the provided washers and nuts firmly secure the cabinet to the base Reinstall the base access door ...

Page 7: ...ate the toothed bracket that has the mounting holes in the flange and mount it to the cabinet below the previously installed hoist plate using the included hardware 3 Determine the top height of the cabinet Drill a 5 8 hole 8 inches below the anticipated height of the cabinet all the way through the pole Note Clearfield does not provide the mounting hardware Required hardware includes a 5 8 thread...

Page 8: ...f the pole It is suggested to add 3 to the diameter of pole for rod length Note Clearfield does not recommend using lag bolts to mount cabinet to pole Clearfield recommends using hardware with a minimum of 5 8 diameter Care should be taken to avoid over tightening and deforming the hoist plate Lock tight red should be used on nuts to prevent loosening of nuts Make sure the thread rod nut does not ...

Page 9: ...Direct 763 476 6866 National 800 422 2537 www SeeClearfield com techsupport clfd net Manual 021814 REV A Jan 2021 6 Level cabinet and drill 5 8 hole through lower bracket and pole and install 5 8 rod washers and nuts Note Care should be taken to avoid over tightening and deforming the hoist plate 7 Cabinet Fully Mounted ...

Page 10: ...s feeder leg will be connected to feeder port 1 and its distribution legs will be connected to distribution ports 1 32 Splitter 2 will connect to feeder port 2 and distribution ports 33 64 and so on for the number of splitters pre installed in the ordered configuration If you wish to pull service from a pre installed splitter leg the connector can be installed into one of the adapters in the provi...

Page 11: ...ching of the end face Learn the process of cleaning properly Note It is NOT recommended to use isopropyl alcohol to clean the end face Cleaning an SC LC Connector Cleaning the End Face Place one wiping paper on QbE 2 FiberSafe Cleaning Platen Figure 1 Apply small amount of precision cleaner about 1 in diameter with Electro Wash MX pen on to one end of the wipe Figure 2 Hold end face at a 90 degree...

Page 12: ...ter AND the Adapter Itself Lightly moisten the fiber optic swab 2 5mm 38542F or 1 25mm 38040 by spotting a small amount about 1 of Electro Wash PX or Electro Wash MX pen onto the QbE Hold the tip of the swab onto the wetted area and hold for a count of 1 2 3 4 5 Insert the swab into the adapter to the connector press lightly against the connector twist 2 3 times remove and discard Dry with a secon...

Page 13: ...pins with this or an equivalent type swab Cleans ALL MTP MPO connector end faces This swab also cleans the pins of the male connector Lightly spot a QbE 2 wipe on the platen with Electro Wash PX Fiber Optic Cleaner the FiberWash or MX Pen Lightly touch short side of the MTP MPO Connector Swab to the wetted area 3 5 secs to absorb some cleaning solution DO NOT over saturate the swab Wipe connector ...

Page 14: ...t pins Cleaned like a single fiber connector using a cleaning platform The receptacles will be cleaned as long as you are using a combination clean ing process as recommended Again using a platen moisten the platen with cleaning solvent on one end to accommodate 3 swipes of the MPO female endface Holding the connector If APC slightly at an angle to accommodate for 8 angle swiping with medium press...

Page 15: ...ace separately or through the adapter Slightly engage probe by pulling back but do not allow to click Lightly spot a QbE 2 wipe on the platen with Elec tro Wash PX Fiber Optic Cleaner this will help alleviate over saturation of the material Lightly touch the tip of probe and release Wipe Material Wet End Face Dry Insert connector or insert probe though adapter and click 2 3 times to move past the ...

Page 16: ...he option of Clearfield Inc shall constitute the exclusive sole remedy for a breach of this limited warranty Clearfield shall not be liable under any circumstances for any special consequential incidental punitive or exemplary damages arising out of or in any way connected with the product or with agreement to sell product to buyer including but not limited to damages for lost profits loss of use ...

Page 17: ...pplied Every effort has been made to keep the information contained in this document current and accurate as of the date of publication or revision However no guarantee is given or implied that the document is error free or that it is accurate with regard to any specification Technical Support Clearfield Inc can be contacted for any issues that arise with the supplied product If you need to return...