Problem
Possible Cause
Action
Are LCD input icons on Bridge controller?
If not check the folowing:
LD & CD on Auto?
If Peelle power is used to power Peelle inputs,
missing jumper from Input Com terminal to V–
terminal on Car Door controller
If external power is used to power Peelle inputs,
missing external power reference wire on Input
Com terminal on Car Door controller
Is antenna icon solid on Bridge controller?
If not...
Check CAN connection from Bridge Controller to
Car Door Controller
Are LCD input icons on Car Door controller?
If not check the folowing:
Ensure external power reference is wired to Input
Com. See page 22
Note: ensure no connections to Peelle V+/V-
Ensure parameter P50 is set to 00.
Ensure input 5 is off on Landing Door controller.
See page 10
See Automatic Mode chart
Door may be mechanically obstructed. Fix
obstruction.
If there is not enough power in slow speed for final
open or final close, increase the following
parameter(s) in multiples of 5 until fixed:
Open direction - P27
Close direction - P48
Bridge controller is sending
signals to car door controller but
no Landing/Car Door operation
in close direction
Light curtain obstructed
Check light curtain alignment
For dual light curtains ensure P65 is set to 047 on
car door controller
Add jumper from Input Com to V-. See page 22
Landing Door stop input on
Add jumper from Input Com to V-. See page 22
Ensure external power reference is wired to Input
Com. See page 22
Ensure external power reference is wired to Input
Com. See page 22
Note: ensure no connections to Peelle V+/V-
Ensure parameter P50 is set to 00 on Car Door
Controller
Elevator controller is sending
outputs to Bridge controller but
no Landing / Car Door
operation in open or close
direction
Bridge controller is sending
signal to car door controller but
no Landing/Car Door operation
in open or close direction
If Peelle power is used to power Peelle inputs,
missing jumper from Input Com terminal to V–
terminal on Car Door controller
If external power is used to power Peelle inputs,
missing external power reference wire on Input
Com terminal on Car Door controller
Landing/Car door stopped before final
open/close