38
FREIGHT DOORS
I
CAR GATES
I
CAR ENCLOSURES
T
ECHNICAL
S
UPPORT
1-800-787-5020 ext 275
THE PEELLE COMPANY
®
Guide No.
VERSION:
Date:
254-EN
WIRELESS CONTROLLER & BRIDGE
INSTALLATION & INTERFACE GUIDE
Mar 07 / 2018
Parameter Description
Range
Bridge Pre Set
15
Auto Close Timer
00 = Disabled
30 - 300 = Enabled time in seconds (30, 45, 60, 90, 120, 150, 180, 300)
00-300
00
16
New York City Fire Service
00 = Disabled
01 = Enabled
00-01
00
17
Dual Light Curtains (Test Output)
00 = Disabled
01 = Enabled
Note: Also set parameter 65 on Car Door Controller to 07
00-01
00
18
USER 1 options
00 = USER 1 POSITION - FRONT
01 = USER 2 POSITION - FRONT
02 = ZONE - FRONT
03 = BUZZ / STROBE - FRONT
04 = DOOR OPEN POSITION - FRONT
06 = AUX 2 INPUT - FRONT
07 = LIGHT CURTAIN TEST OUTPUT (BRIDGE OPTION ONLY)
08 = USER 1 POSITION - REAR
09 = USER 2 POSITION - REAR
10 = ZONE - REAR
11 = BUZZ / STROBE - REAR
12 = DOOR OPEN POSITION - REAR
13 = AUX 2 INPUT - REAR
00-13
00
19
USER 2 options
00 = USER 1 POSITION - FRONT
01 = USER 2 POSITION - FRONT
02 = ZONE - FRONT
03 = BUZZ / STROBE - FRONT
04 = DOOR OPEN POSITION - FRONT
06 = AUX 2 INPUT - FRONT
07 = LIGHT CURTAIN TEST OUTPUT (BRIDGE OPTION ONLY)
08 = USER 1 POSITION - REAR
09 = USER 2 POSITION - REAR
10 = ZONE - REAR
11 = BUZZ / STROBE - REAR
12 = DOOR OPEN POSITION - REAR
13 = AUX 2 INPUT - REAR
00-13
00
20
Software Version (Read Only)
2 digits
Software
Version
Restore Factory Default Settings
00 – Exit without saving
01 – Restore all Deafult parameters
21
00-01
00
6.3 BRIDGE CONTROLLER PARAMETERS
L
Bridge Controllers will show a “br” on the LCD display
Summary of Contents for 254-EN
Page 2: ......