![PEDROLLO DG PED 3 Instructions For Use Manual Download Page 28](http://html1.mh-extra.com/html/pedrollo/dg-ped-3/dg-ped-3_instructions-for-use-manual_1520147028.webp)
28
| ENGLISH
ALARMS
GREEN LED FL RED LED FLASHING
RED LED
FLASHING
GREEN LED
FLASHING
ALARM 1
= Dry running. Set off after 7 sec. of absence of water in suction.
Check the presence of water in aspiration and fill the pump.
DG PED will effect automatic attempts to restart after 1 min, 15 min, 30 min,
1 h, 1 h, etc.
ALARM 2
= The pump does not reach the set pressure. Contact a repair centre.
ALARM 3
= The pressure of the pre-load of the vase is too low; inflate the vase to 50% of
the work pressure (eg. if one works at 3 bar inflate the vase to 1.5 bar).
ALARM 4
= Discharge pressure less than 0.2 bar (broken tube), the reset is only manual.
Verify why the pressure has fallen to zero.
ALARM 5
= Supply voltage is too low.
Guarantee an electric current of 230 v. +/- 10%.
ALARM 6
= External OFF signal.
GREEN LED FIXED + RED LED FLASHING
RED LED
FLASHING
GREEN LED
FIXED
ALARM 1
= Short Circuit. Switch off the device and contact a repair centre.
Reset is only manual.
ALARM 2
= Too high a current. The current absorbed exceeds the permitted tolerance.
Reset is only manual. If the problem persists contact a repair centre.
ALARM 3
= Excessive temperature of the module. If the temperature of the liquid is
greater than 40°C. contact a repair centre. Control the temperature of the
pumped liquid.
Automatic reset if the temperature falls below the value of the alarm.
ALARM 4
= Excessive temperature of the motor. If the liquid does not have a tempera-
ture greater than 40°C. contact a repair centre. Control the temperature of
the pumped liquid.
Automatic reset if the temperature falls below the alarm setting.
ALARM 5
= Invalid signal of the pressure sensor. Contact a repair centre.
ALARM 6
= Invalid signal of the flow sensor. Contact a repair centre.
Example:
pump in alarm because
of DRY RUNNING
LED 1 FLASHING
+
RED LED FLASHING
=
DRY RUNNING
Example:
Pump in alarm because
of SHORT CIRCUIT
LED 1 FIXED
+
RED LED FLASHING
=
SHORT CIRCUIT