![PEDROLLO DG PED 3 Instructions For Use Manual Download Page 21](http://html1.mh-extra.com/html/pedrollo/dg-ped-3/dg-ped-3_instructions-for-use-manual_1520147021.webp)
21
ENGLISH |
TECHNICAL DATA
z
Supply voltage ~
230 V
± 10%
z
Frequency
50/60 Hz
z
Insulation:
class F
z
Max absorbed current
–
7.5 A
DG PED 3
–
10 A
DG PED 5
z
P1 Maximum absorbed power:
–
1.0 kW
DG PED
3
– 1.5 kW
DG PED
5
z
Insulation: class
IP X4
z
Factory set point
3 bar
z
Fuse
12.5 A
(rapid intervention)
APPLICATION LIMITS
• Manometric suction lift up to
8 m
• Liquid temperature between
0 °C
and
+40 °C
• Ambient temperaturebetween
0 °C
and
+40 °C
• Max. working pressure
10 bar
• Continuous service
S1
• Vertical position running
CLEAN WATER
DOMESTIC USE
CIVIL USE
CHARACTERISTIC CURVES
0
10
20
30
40
50
60
70
80
90
0
10
20
30
40
50
60
H (m)
Q (l/min)
DG PED 3
Set point 3 bar
max 5.5 bar
min 1 bar
0 10 20 30 40 50 60 70 80 90 100 110
120
130
0
10
20
30
40
50
60
H (m)
Q (l/min)
DG PED 5
Set point 3 bar
max 5.5 bar
min 1 bar
MODEL
POWER
MAX PERFORMANCES
PERFORMANCES (ADJUSTABLE SET POINT)
P2
Q
H
Min. Set Point
Set Point
Taratura Std
Max. Set Point
Single-phase
kW
HP
c
l/min
metres
bar
l/min
bar
l/min
bar
l/min
DG PED 3
0.75
1
IE3
5 – 80
55 – 10
1
35 – 80
3
5 –
58
5.5
5 – 30
DG PED 5
1.1
1.5
5 – 120
55 – 10
1
50 – 120
3
5 –
92
5.5
5 – 50
Q = Flow rate H = Total manometric head
Tolerance of characteristic curves in compliance with EN ISO 9906 Grado 3B.
c
Three phase motor efficiency class (IEC 60034-30-1)
The performances shown refer to a head in aspiration equal to -1 m(aspiration of 1 m.). If the water level in aspira-
tion is less than the depth of entrance of the pump the performances will be reduced accordingly.