Pecon P Lab-tek Series Manual Download Page 12

10

 

Manual: Heating Insert P – Lab-Tek™ type

 

 

 

www.pecon.biz 

12.01.2004 

pe

rfu

sio

n

pu

m

p

ob

se

rv

a

tio

n a

rea

: 2

5 m

m

O

p

e

n C

ult

iv

a

tion

pu

m

p

m

edium bo

ttl

e

Summary of Contents for P Lab-tek Series

Page 1: ...LaCon POCmini LaCon Laminar air flow 37 C 5 0 7 0 CO 2 O2 Stabilization of the environment for cell and tissue culture in vitro CTI Controller 3700 control CO setpoint ventilation speed heating inten...

Page 2: ...tz ist die eingestellte Netzspannung am Ger t zu berpr fen und gegebenenfalls anzupassen Korrekte Sicherung einsetzen Knowledge of this manual is required for the operation of the device Would you the...

Page 3: ...und rechten Seite erm glichen die Durchf hrung von Schl uchen z B f r die Perfusion Der Niveauaus gleich im Mikroskoptisch kann durch vier Schrauben erfolgen Basiseinsatz f r ein Inkubationssystem C...

Page 4: ...mit dem Inkubator S sollte zur Aufrechterhaltung der Luftzusam mensetzung die Beobachtungs ffnung bei nicht eingesetzter Zellkultivierungs einheit durch den roten Einsatz verschlossen werden Einsatz v...

Page 5: ...ich reduziert F r diese ist der Heizeinsatz P 0426 100 mit einem ovalem Beobachtungsbereich 32 x 30 mm m glicherweise besser geeignet POC R und POCmini Beide Zellkultivierungssysteme k nnen direkt mit...

Page 6: ...Inkubator ffnung f hren 1 1 2 Danach wie oben beschrieben schr g unter die Feder klemmung fahren diese nach hinten schieben 2 und dann den Objekttr ger nach unten dr cken 3 3 2 Kontaktinformation Hers...

Page 7: ...w the guidance of tubings e g for perfusion The level in the scanning stage can be adjusted by four leveling screws Basic insert for incubation system C CO2 on inverted microscopes in combination with...

Page 8: ...the heating see manual Tempcontrol When combined with the Incubator S the observation window should be closed with the red insert 0426 103 if no cell cultivation chamber is used to maintain air compos...

Page 9: ...rvation area is reduced For those the Heating Insert P 0426 100 with an oval observation area 32 x 30 mm might be the better solution POC R and POCmini Both cell cultivation systems can be fixed direc...

Page 10: ...ide of the incubator opening 1 1 3 Then guide the slide inclined below the spring clamping and slide it back 2 then push the chamber to the bottom 3 3 2 Contact information Manufacturer PeCon GmbH Rin...

Page 11: ...l amplifier 2 0425 200 bypass Special feature Bypass System in which the conditioned air stream may be diverted through a channel before the cover is removed The LD condenser 0 55 may be used cover ob...

Page 12: ...10 Manual Heating Insert P Lab Tek type www pecon biz 12 01 2004 perfusion pump observation area 25 mm Open Cultivation pump medium bottle...

Page 13: ...eilen Basisring Folie und Spannring und l sst sich sehr leicht montieren Die Sterilisation erfolgt nach der Montage im Autoklav 121 C oder durch Trockensterilisation bei ca 165 C Wenn die Folie nach G...