Pearl HYPERSONIC GCA206XL User Manual Download Page 6

ROUTINE CLEANING

CLEANING THE UNIT BODY

Before it gets obviously dirty

DRAINING AND CLEANING 

THE DRAIN TANK

CLEANING THE AIR FILTER

At least once a week

Around once a week

Clean the unit with a soft cloth.

If the unit gets very dirty , clean with a soft cloth dampened 

with neutral cleaning agent, then clean with a soft dry cloth.

Remove the dirt from the sensor (to prevent malfunction).

The water blown off the hands is called “drain water”. 

Empty the drain water regularly in order to prevent 

overflow. The drain water will start smelling if it remains 

in the tank for too long.

Pull the air filter out 

by the handle.

Slide the filter back into 

the unit, making sure 

that it goes all the way 

in. (If it is not in place, 

dirt or dust will enter 
the unit and shorten its 
service life).

Clean the filter by 

tapping lightly by hand 

or using a vacuum 

cleaner.
If it is very dirty, wash 

it with cold or warm 

water. Let air dry.

If you wash the filter with water, be sure to 

dry it as much as possible
Do not expose to fire or intense heat

Before you clean the unit, turn off the 

power switch.
Do not splatter water on the unit

Wear gloves when cleaning

The antibacterial coating is effective when 

bacteria are exposed to the coated 

surfaces. The coating is ineffective when 

the surfaces are very dirty.

Pull the drain tank out 

horizontally.
This ensures the 

drain water does not 

splatter out.

WARNING

NOTE

CAUTION

NOTE

NOTE

Only use neutral cleaning agents.
Do not use thinner, acidic or alkaline cleaners, or nylon 

brushes (they may cause damage to the surface). 
Do not use any alcohol to clean the machine. 
Disinfecting agents will damage your unit.
Read the labels of cleaning products to see if they are

safe for use.

1

DRAIN TANK

HANDLE

AIR FILTER

Open the cover and empty 

the water.

2

1

2

3

3

Close the water tank cover, 

and re-attach it to the unit.

Add 1 cup of water through 

the drain hole to prevent 

clogging.

Test the unit after confirming 

the tank is back in its place.

DRAIN TANK

COVER

Wash out the interior of the 

drain tank.

DRAIN 

HOLE

5

Summary of Contents for HYPERSONIC GCA206XL

Page 1: ...LIFEWITHPEARL COM A U T O M A T I C H A N D D R Y E R P R O F E S S I O N A L H Y P E R S O N I C GCA206X L USER MANUAL...

Page 2: ...setup and safe usage Please keep the manual for future reference CONTENTS CHASE DRYER FEATURES SPECIFICATIONS Easy and comfortable to use ENGINEERED FOR HUMANS CONTENTS FEATURES SPECIFICATIONS WARNIN...

Page 3: ...er to check and repair Machine must have reliable ground connection Do not install when the machine is connected to a power source Unit must be installed by a professional tradesperseon This appliance...

Page 4: ...ATING SWITCH SPEED SWITCH DRYING TIME AND FAULT DISPLAY POWER INDICATOR SELF CHECK INDICATOR HAND DRYING AREA LAMP UNIT DRAIN HOSE AIR FILTER DRAIN TANK TERMINAL BOX LOCATION POWER CORD HOSE REAR INST...

Page 5: ...o off then turn on the power switch If the indicator still lights up or flashes turn off the power disconnect the unit from the socket and contact your dealer immediately Attach the usage label in a v...

Page 6: ...If you wash the filter with water be sure to dry it as much as possible Do not expose to fire or intense heat Before you clean the unit turn off the power switch Do not splatter water on the unit Wear...

Page 7: ...r Is there any dirt on the sensor Is the internal heating fuse burned Is the ambient temperature higher than than 25 C Clean off dirt see 2 above Turn off power switch Remove the front panel and you w...

Page 8: ...OWING PLACES Install at a location where the unit will be easy to use as shown in the figure The bottom of the unit must be at least 150mm higher than the floor or any objects under it If the unit is...

Page 9: ...box in the installation location 1 switchbox no cover and wire the power cord the green and yellow combined is the ground line Pull the power cord into the unit and secure inside Pull the power cord t...

Page 10: ...necting the ground wire Tighten the screws on the terminal box and pull the power cord to make sure it is secured firmly Bind the powercord using the clip to the right of the terminal box and fix it t...

Page 11: ...Inc 120 1231 Burdette Street Richmond BC Canada V6V 2Z2 MAIN MACHINE 1 MOUNTING PLATE 1 5x25mm SELF TAPPING SCREW 6 5mm EXPANSION PIPE 6 USER MANUAL 1 METHOD OF USE FIGURE 1 ROUGHING EFFICIENCY AIR F...

Page 12: ......

Reviews: