Pearl HYPERSONIC GCA206XL User Manual Download Page 10

INSTALLATION PROCEDURES

TEST RUN

5

6

7

1

2

3

4

5

STEP

CHECK

Check the power supply voltage

Turn the ground-fault  circuit breaker on

Turn the power switch on

Insert hands into sensor area

Check the unit

Make sure it matches the rated voltage

Does the power indicator light up?

Is the air blowing?

Is it installed firmly? Any vibrations or strange noises?

WARNING

Do not turn the unit power switch on with your hands inside. If the self-check 

indicator display light is flashing, turn off the power switch, and turn

the power back on when all indicators turn off (after 40 seconds)

Wire the terminal box

Strip the wire sheath as shown in the 

figure on the right
Loosen the screws on the terminal box 

and the power cord to the terminal box.
Remove the protective seal attached to 

the terminal box before connecting the 

ground wire.
Tighten the screws on the terminal box 

and pull the power cord to make sure it is 

secured firmly.
Bind the powercord using the clip to the 

right of the terminal box and fix it to its 

original location.

Attach the front panel

Insert the 3 front panel chuckholes into 

the unit.
Replace the 2 screws that were removed.

Attach the terminal box cover

Place the internal box tabs into the holes and return 

the cover to its original position, securing it with the 

screws.
Make sure the power cord and other wires are not 

pinched.
The front panel cannot be attached if there are any 

wires in front of the terminal box cover. Move the 

wires to the right of the termainal box cover.

Attach the drain tank.
Make sure the air filter is all the way in.

1)

1)

2)

1)

2)

3)
4)

2)

3)

4)

5)

h H

50

15

h H

UNSCREW HERE 

TO CHANGE FUSE

TERMINAL BOX

POWER CORD

EARTH WIRE

POWER CORD

POWER CORD

RETAINER

TERMINAL BOX COVER

TERMINAL BOX

FRONT PANEL

DRAIN TANK

AIR FILTER

INSTALLATION SCREW

TERMINAL BOX 

COVER SCREW

9

Summary of Contents for HYPERSONIC GCA206XL

Page 1: ...LIFEWITHPEARL COM A U T O M A T I C H A N D D R Y E R P R O F E S S I O N A L H Y P E R S O N I C GCA206X L USER MANUAL...

Page 2: ...setup and safe usage Please keep the manual for future reference CONTENTS CHASE DRYER FEATURES SPECIFICATIONS Easy and comfortable to use ENGINEERED FOR HUMANS CONTENTS FEATURES SPECIFICATIONS WARNIN...

Page 3: ...er to check and repair Machine must have reliable ground connection Do not install when the machine is connected to a power source Unit must be installed by a professional tradesperseon This appliance...

Page 4: ...ATING SWITCH SPEED SWITCH DRYING TIME AND FAULT DISPLAY POWER INDICATOR SELF CHECK INDICATOR HAND DRYING AREA LAMP UNIT DRAIN HOSE AIR FILTER DRAIN TANK TERMINAL BOX LOCATION POWER CORD HOSE REAR INST...

Page 5: ...o off then turn on the power switch If the indicator still lights up or flashes turn off the power disconnect the unit from the socket and contact your dealer immediately Attach the usage label in a v...

Page 6: ...If you wash the filter with water be sure to dry it as much as possible Do not expose to fire or intense heat Before you clean the unit turn off the power switch Do not splatter water on the unit Wear...

Page 7: ...r Is there any dirt on the sensor Is the internal heating fuse burned Is the ambient temperature higher than than 25 C Clean off dirt see 2 above Turn off power switch Remove the front panel and you w...

Page 8: ...OWING PLACES Install at a location where the unit will be easy to use as shown in the figure The bottom of the unit must be at least 150mm higher than the floor or any objects under it If the unit is...

Page 9: ...box in the installation location 1 switchbox no cover and wire the power cord the green and yellow combined is the ground line Pull the power cord into the unit and secure inside Pull the power cord t...

Page 10: ...necting the ground wire Tighten the screws on the terminal box and pull the power cord to make sure it is secured firmly Bind the powercord using the clip to the right of the terminal box and fix it t...

Page 11: ...Inc 120 1231 Burdette Street Richmond BC Canada V6V 2Z2 MAIN MACHINE 1 MOUNTING PLATE 1 5x25mm SELF TAPPING SCREW 6 5mm EXPANSION PIPE 6 USER MANUAL 1 METHOD OF USE FIGURE 1 ROUGHING EFFICIENCY AIR F...

Page 12: ......

Reviews: