INSTALLATION PROCEDURES
TEST RUN
5
6
7
1
2
3
4
5
STEP
CHECK
Check the power supply voltage
Turn the ground-fault circuit breaker on
Turn the power switch on
Insert hands into sensor area
Check the unit
Make sure it matches the rated voltage
Does the power indicator light up?
Is the air blowing?
Is it installed firmly? Any vibrations or strange noises?
WARNING
Do not turn the unit power switch on with your hands inside. If the self-check
indicator display light is flashing, turn off the power switch, and turn
the power back on when all indicators turn off (after 40 seconds)
Wire the terminal box
Strip the wire sheath as shown in the
figure on the right
Loosen the screws on the terminal box
and the power cord to the terminal box.
Remove the protective seal attached to
the terminal box before connecting the
ground wire.
Tighten the screws on the terminal box
and pull the power cord to make sure it is
secured firmly.
Bind the powercord using the clip to the
right of the terminal box and fix it to its
original location.
Attach the front panel
Insert the 3 front panel chuckholes into
the unit.
Replace the 2 screws that were removed.
Attach the terminal box cover
Place the internal box tabs into the holes and return
the cover to its original position, securing it with the
screws.
Make sure the power cord and other wires are not
pinched.
The front panel cannot be attached if there are any
wires in front of the terminal box cover. Move the
wires to the right of the termainal box cover.
Attach the drain tank.
Make sure the air filter is all the way in.
1)
1)
2)
1)
2)
3)
4)
2)
3)
4)
5)
h H
50
15
h H
UNSCREW HERE
TO CHANGE FUSE
TERMINAL BOX
POWER CORD
EARTH WIRE
POWER CORD
POWER CORD
RETAINER
TERMINAL BOX COVER
TERMINAL BOX
FRONT PANEL
DRAIN TANK
AIR FILTER
INSTALLATION SCREW
TERMINAL BOX
COVER SCREW
9