7. INSTALLATION

6. PRODUCT STRUCTURE

PRODUCT STRUCTURE 

cont...

POS. PART

Pump body

2 Impeller

O-sealing ring

4  

Motor connector

5 Motor

Terminal box

7  

Coupling

Mechanical seal

9  

Keys

POS. PART

Pump cover

2 Impeller

O-sealing ring

O-sealing ring

Pump body

Mechanical seal

Water proof ring

8 Bracket

9 Fan

5.5. Make sure the pump is 

installed in a well-aired place.

5.6. Before carrying out 

checks or doing any main-

tenance,

clear the system by 

disconnecting the voltage, 

and then remove the pump 

plug from the socket.

5.7. Ensure the pump will not 

be accidently turned on

while installing and  

maintaining; if not used 

for a long time, cut off the 

power first and then turn off 

valves in inlet and outlet of 

the pump.

5.8. The pump must operate 

with clean water. It is not

suitable for pumping 

inflammable, gasified or 

explosive liquids.

5.9. The power supply shall 

be in accordance with the

voltage stated on the 

nameplate.

4

1 2

3

4

5

6

7

8
9

1 2

3 4 5 6 7

8

9 10

11

12

13
14

1 2

3

4

5

6

7

8
9

1 2

3 4 5 6 7

8

9 10

11

12

13
14

DNM

B

h1

h2

h

aw

L

DNA

m1

s

n n1

m

DNM

DNA

a

L

B

h1

h2

h

m1

m

b

s

n

n1

b

MODEL

DNM DNA a h2 w x b c h1 m m1 n n1 s B Hmax L

CEP 50

50

50

70 210 258 127 50 12 136 100 70 240 190 14 255 346 450

CEP 75 

137 210 263 180 60 15 160 22 70 272 212 14 308 370

570

CEP 100

591

CEP 150

93 252 309 245 65 20 160 260 210 314 254 15 322 412 787

CEP 200

8. PERFORMANCE DATA

MODEL

speed 

(r/min)

Rated flow

(m3/h)

Rated flow

(m)

Power

(kW)

CEP 50

3500

24

38

4

CEP 75 

16

61

5.5

CEP 100

19

75

7.5

CEP 150

31

60

11

CEP 200

35

70

15