9. PRIOR TU USE

During installation apply all the safety regulations 

issued by thecompetent authorities and dictated by 

common sense.

9.1.With the appropriate bolts secure the pump to flat and solid 

surfaces toavoid vibrations. The resistance of the motor shall be 

more than 50M

Ω

.

9.2. Before startup, check if the pump turns freely by rotating 

the fan. Remove the filling plug and fully fill the pump chamber 

with clean water, then tighten the filling plug.

9.3. In case the electric pump is far from the power supply, it’s 

necessary to use a thicker cable. Otherwise the pump cannot 

work properly due to the big voltage drop.

9.4. Do not use soft rubber tube for inlet pipeline during 

installation. A foot valve shall be vertically installed with a 

distance of at least 30 cm from the water bottom to avoid 

suction of sediment.

9.5. Pay attention to the water level during operation. The foot 

valve shall not be above the water surface.

9.6. If the pump is not be used for a long time, it is advisable to 

empty it completely, wash it with clean water and store it in a 

dry, well-ventilated

place.

This product shall be installed and maintained by a 

qualified person who is proficient with this instruction.

The installation and operation must be in accordance 

with local regulations and the recognized operation 

criteria. Install the pipeline properly according to the 

requirement of this instruction, and protect it from 

freezing.

CORRECT INSTALLATION

A DIAGRAM 

CORRECT INSTALLATION

B DIAGRAM 

1. Discharge plug

2. Electric pump

3. Outlet pipeline

4. Joint

5. Filling plug

6. Inlet pipeline

7. Foot valve

8. Support

NOTES FOR INLET PIPELINE INSTALLATION:

1. Do not use too soft rubber tube for the inlet pipeline during 

pump installation.

2. The foot valve should be vertically installed 30cm from water 

bottom to avoid suction of sediment (A)

3. All connections of the inlet pipelines must be sealed. 

To ensure water suction, it’s necessary to reduce the quantity 

of bents of the pipelines.

4. The diameter of the inlet pipe must not be less than that of 

the pump inlet to avoid big hydraulic loss and small water flow.

5. Pay attention to the water level during operation. The foot 

valve shall not be above the water surface (B).

6. In case the inlet pipe is longer than 10m in length or over 4m 

in hoisting height, the pipe diameter should exceed diameter of 

water inlet of the pump.

7. The pipelines should be anchored so that no stresses  

whatsoever is transmitted to the pump.

8. It is recommended to install a filter on inlet pipeline to avoid 

incoming of solid particles to the electric pump.

NOTE FOR OUTLET PIPELINE INSTALLATION:

The diameter of the outlet pipeline shall be not less than that of 

the pump outlet to reduce the pressure drop, high flow rate and 

noise to the lowest level.

10. ELECTRICAL CONNECTIONS

Make sure that there is no voltage at the line wire 

terminals before connecting.

The electric pump shall be grounded reliably to avoid 

electric leakage and an earth leakage circuit breaker 

shall be equipped.

The electrical connection shall be carried out according to the 

local regulations.

Check that the pump operates within the specified range on the 

nameplate.

Connect up the pump (making sure that there is an efficient 

grounding circuit) according to the diagram on the nameplate on 

the motor.

The correct direction of rotation for three-phase motors is 

clockwise, looking at the pump from the motor fan side. If this is 

not the case, invert two of the phases.

switch

fuse

pressure 

switch 

magnetic 

thermal 

switch 

switch

fuse

pressure 

switch 

magnetic 

thermal 

switch 

Direct ConnectionY

/

 

Connection

L

1

L

2

L

3

M

3~

M

3~

L

1

L

2

L

3

M

3~

M

3~

L

1

L

2

L

3

L

1

L

2

L

3

T

1

T

2

T

3

T

1

T

2

T

3