EXCESSIVE NOISE.
Lack of lubrication to the gearbox and
or possible bearing wear. Have tool serviced.
BLADE WILL NOT CUT.
Check for worn out diamond edge.
Be sure that the arrow on the blade is rotating the same
direction as the motor arbor and/or arrow on the blade
guard. Make sure the blade is suitable for the material to be
cut. If blade has been used to cut a material that is hard, it
may have become dull, dress the blade by cutting a light
weight abrasive building block to expose fresh diamonds.
Blade dressing stones are available from your local Pearl
Warehouse.
MOTOR WILL NOT START.
Check power supply. If the
water pump turns on when the power switch is in the “on”
position, but the motor does not, have the motor serviced.
MOTOR WILL NOT STOP.
The contacts in the switch may
have become arched together in the on position, have it
serviced.
MOTOR SHUTS OFF DURING OPERATION.
Check to see
that the circuit you are using is not overloaded with lights
or other equipment. The fuse or circuit breaker may not
have sufficient capacity, use 20-amp power. If you are
using an extension cord check the extension cord table to
be sure it is heavy enough to carry the current this product
will draw.
See Page 21 for electric cord reference.
EXCESSIVE VIBRATION
Check to see that the blade is
mounted properly according to safe operating practices
section. Blade may be out of balance, try a different blade.
Arbor shaft bearings possibly worn, have tool serviced.
NOT CUTTING SQUARE.
Check the main table and carriage
adjustment as well as the blade alignment procedure
located in the care and maintenance section.
MAIN TABLE DOES NOT MOVE FREELY.
Inspect the guide
rails and rollers for build up of tile chips or dry slurry
deposits. Clean and check guide roll or adjustments,
according to the procedure in the care and maintenance
section.
NO WATER FLOW TO BLADE.
Check the water feed tube
for kinks or obstructions. Check the inlet screen to ensure
it is not clogged. Remove the pump inlet and turn the
impeller to ensure it is not damaged or jammed. Clean the
impeller if necessary and apply a drop of light oil to the
shaft - be sure the impeller spins freely.
POOR MACHINE PERFORMANCE WITH LITTLE POWER.
Check cord/extension cable for appropriate length and
gage. Check power network for sufficient power and circuit
breaker capacity.
CENTER HOLE IN BLADE OVERSIZE OR WORN.
Saw blade
has slipped on shaft while running. Check shaft for damage
and replace blade.
xviii. TROUBLESHOOTING
For your safety and the safety of others, turn the power switch off and always remove the
plug from power source before troubleshooting. Repairs performed by unauthorized personnel could cause
serious hazard. We recommend that service to this tool be performed by a qualified service technician with
original equipment replacement parts.