6.1. Input Terminals
The following items describe the input terminals (See Table 1 for input limits).
10 A:
For current measurement (AC or DC) up to 10 A when you pressed FUNCTION
– Switch at DC A or
AC A.
µA/mA-input:
For current measurements (AC or DC) up to 500 mA, when you pressed FUNCTION
– Switch at µA
or mA.
COM:
Return terminal for all measurement (black test lead).
V/
:
Volts, Ohm, Continuity, Diode, Frequency and Logic Test terminal (red test lead).
6.2. Digital LED-Displays
1. Digital Display
Digital readings are displayed on a 53.000 counts display with automatic polarity indication and
decimal point placement.
2. OL (Overload indication)
OL is displayed and beep sounds when input is too excessive to display.
6.3. Using the programmed function FUNC
Automatical and manual range selection
Range-button RANGE
*
Select your function to measure
*
Press the RANGE-button to activate the manual range-selection.
*
Press the RANGE-buttons to choose the range for measurement
*
To release this function and hold RANGE-Button for 2 seconds-
6.4. Data Hold
The Data Hold feature lets you hold a reading on the display. To turn on the hold feature, press
HOLD-button. "HOLD" appears on the display. To release this function, press HOLD button again.
-31-