MULTIMETER

OPERATING INSTRUCTIONS

GUARANTEE ........................ 21

COD.58515

Summary of Contents for EgaTronic COD.58515

Page 1: ...MULTIMETER OPERATING INSTRUCTIONS GUARANTEE 21 COD 58515...

Page 2: ...cy Transistor Diode and Continuity but also have Data Hold Full Icon Display Overload Protection and Sleep Mode features UNPACKING INSPECTION Open the package case and take out the Meter Check the fol...

Page 3: ...position and no any changeover of range shall be made during measurement is conducted to prevent damage of the Meter When the Meter working at an effective voltage over 60V in DC or 30V rms in AC spe...

Page 4: ...y as it may leak when it has been using for some time replace the battery as soon as leaking appears A leaking battery will damage the Meter INTERNATIONAL ELECTRICAL SYMBOLS AC Alternating Current DC...

Page 5: ...y Measurement Diode test Continuity test Resistance measurement FUNCTIONAL BUTTONS Bellow table indicated for information about the functional button operations Button Operation Performed Yellow Butto...

Page 6: ...ut terminals 9 hFE The Unit of Transistor Test 10 mV V V Volts The unit of voltage mV Millivolt 1 x 10 3 or 0 001 volts k MG Ohm The unit of resistance k kilohm 1 x 103 or 1000 ohms M Megaohm 1 x 106...

Page 7: ...oss with the object to be measured The measured value shows on the display Note If de value of voltage to be measured is unknown use the maximum measurement position 1000V and reduce the range step by...

Page 8: ...rement has 3 measurement positions on the rotary switch 20mA 200mA and 20A To measure current do the following 1 Turn off power to the circuit Discharge all high voltage capacitors 2 Insert the red te...

Page 9: ...and discharge all the high voltage capacitors before measuring resistance The resistance ranges are 200 2k 20k 2M and 200M To measure resistance connect the Meter as follows 1 Insert the red test lead...

Page 10: ...COM terminal 2 Set the rotary swich to 3 For forward voltage drop readings on any semiconductor component place the red test lead on the component s anode and place the black test lead on the compone...

Page 11: ...f the Meter E FREQUENCY MEASUREMENT see figure 7 figure 7 Warning To avoid harms to you never attempt to input voltages higher than 60V DC or V rms in AC When the voltage of tester frequency signal is...

Page 12: ...mperature connect the Meter as follows 1 Insert the and temperature probe into corresponding V and COM terminal 2 Set the rotary switch to C 3 Place the temperature probe s tip to the object being mea...

Page 13: ...nto the mA and V terminal 2 Set the rotary switch to an appropriate measurement position in Fcx range 3 Insert the tested object into the corresponding jack of the multi purpose socket or connect the...

Page 14: ...nto the V and mA terminal 2 Set the rotary switch to hFE range 3 Insert the NPN or PNP type transistor to be tested into the corresponding jack of the multi purpose socket The measured nearest transis...

Page 15: ...ta Holding Display Temperature Operating 0 C 40 C 32 F 104 F Storage 10 C 50 C 14 F 122 F Relative Humidity 75 0 C below 30 C 50 30 C 40 C Altitude Operating 2000m Storage 10000m Electromagnetic Compa...

Page 16: ...ion 2mA 0 0001mA 0 5 5 CE Version Fuse 0 5A 250V fast type 5x20mm 200mA 0 01mA 0 8 5 20A 0 001A 2 10 Un Fused Remarks At 20A Range for continuous measurement 10 seconds and interval time between 2 mea...

Page 17: ...nal resistance from the test lead Then use the equation measurement resistance value Y X accurate readings of resistance F Diodes and Continuity Test Range Resolution Accuracy Overload Protection Diod...

Page 18: ...tion Warning Do not attempt to repair or service your Meter unless you are qualified to do so and have the relevant calibration performance test and service information To avoid electrical shock or da...

Page 19: ...the 3 screws from the case bottom and separate the case top from the case bottom 4 Remove the fuse by gently prying one end loose then take out the fuse from its bracket 5 Install ONLY replacement fus...

Page 20: ...p and reinstall the 3 screws and the holster NOTES IMPORTANT The maker will not take responsibility for damage or malfunction as a result of the device being incorrectly used or applied for a purpose...