A. DC Voltaje
Range
Resolution
Accuracy
Overload Protection
200mV
0.01mV
±(0.05%+3)
250V DC / V AC
2V
0.0001V
±(0.1%+3)
1000V rms
20V
0.001V
200V
0.01V
1000V
0.1V
±(0.15%+5)
Remarks
: Input Impedance: approx. 10M
Ω
.
B. AC Voltaje
Range
Resolution
Accuracy
Overload Protection
2V
0.0001V
±(0.5%+10)
1000V rms
20V
0.001V
200V
0.01V
1000V
0.1V
±(1%+10)
Remarks
:
•
Input Impedance
: approx. 2M
Ω
.
•
Frequency response:
40Hz
~400Hz.
•
Displays effective value of sine wane (mean value response).
C. DC Current
Range
Resolution
Accuracy
Overload Protection
2mA
0.0001mA
±(0.5%+5)
CE Version: Fuse
0.5A, 250V, fast
type,
Ф5x20mm
200mA
0.01mA
±(0.8%+5)
20A
0.001A
±(2%+10)
Un-Fused
Remarks
:
•
At 20A Range
: for continuous measurement
≤10 seconds and interval time
between 2 measurement greater than 15 minutes.
•
Measuring Voltage Drop:
Full Range is 200mV
.
D. AC Current
Range
Resolution
Accuracy
Overload Protection
20mA
0.0001mA
±(0.8%+10)
CE Version: Fuse
0.5A, 250V, fast
type,
Ф5x20mm
200mA
0.01mA
±(1.2%+10)
20A
0.001A
±(2.5%+10)
Un-Fused
Remarks
:
•
Frequency reaponse
:
40Hz
~400Hz.
•
At 20A Range
: for continuous measurement
≤10 seconds and interval time
between 2 measurement greater than 15 minutes.
•
Measuring Voltaje Drop:
full range is 200mV.
•
Displays effective value of sine wave (mean value response).