background image

4. Controls and Indications (P 1570 and P 1580) 

 
 

 
 
 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  1.  LED panel meter display with CC/CV Indictor 
  2.  Rear Control Indicator

 (lights up when using Preset/ Remote Control/ Set mode) 

  3.  Output Voltage Control Knob

 (control both the main and auxiliary output voltage) 

  4.  Output Current Control Knob

 (control both the main and auxiliary output current limit)

 

  5.  Power ON/OFF Switch 
  6.  Aux. output terminal (max 5A) 

 

Note : 

The total rated current is 60 A (P 1570) resp. 30 A (P 1580) (Aux.+Main) 

 
  7.  Output Terminal

  

 

  8.  Remote Sensing Terminal

  (P 1570 only)

 

  9.  Mode Selection Switch

 (Normal, Preset, Remote Control, Set Modes) 

 

10.  Recall Selection Switch  

11.  Remote Control Terminal  

12.  Cooling Fan Air Intake Grille  
13.  AC Input Plug 
14. USB port. For access to computer to run cyclical operation with programmable voltage, 

current, period time and cycle. 

 
 
 
 
 
 
 
 

-37- 

Summary of Contents for 1565

Page 1: ...Bedienungsanleitung Operation manual DC Schaltnetzteile mit USB Schnittstelle Switching Mode DC Power Supplies with USB interface PeakTech 1565 1570 1575 1580 1585 ...

Page 2: ...A P 1570 20 A P 1575 30 A P 1580 15 A P 1585 belasten ansonsten könnte dies zu Beschädigungen des Gerätes führen Nehmen Sie das Gerät nie in Betrieb wenn es nicht völlig geschlossen ist Defekte Sicherungen nur mit einer dem Originalwert entsprechenden Sicherung ersetzen Sicherung oder Sicherungshalter niemals kurzschließen Gerät und Zubehör vor Inbetriebnahme auf eventuelle Schäden bzw blanke oder...

Page 3: ...tung sorgfältig lesen und die darin befindlichen Sicherheitshinweise unbedingt beachten Für Referenzzwecke Bedienungsanleitung immer in der Nähe des Gerätes griffbereit halten bzw aufbewahren HINWEIS Labornetzgeräte sind nicht zum Laden von Batterien konzipiert Eine solche Benutzung kann zu schwerwiegenden Beschädigungen am Gerät führen welche von Ansprüchen jeglicher Art ausgeschlossen sind Betri...

Page 4: ...AUX Ausganges für Belastungen bis max 5A Front Hinweis Die maximale Strombelastung beträgt 40 A P 1565 20 A P 1575 15 A P 1585 AUX Hauptausgang 7 Anschlüsse des Hauptausgangs an der Rückseite für Strombelastungen bis 40 A P 1565 20 A P 1575 15A P 1585 8 Auswahlschalter für Modus Normal Preset Remote Control oder Set 9 Recall Auswahlschalter zur Auswahl von 3 verschiedenen Festspannungen 5 V 13 8 V...

Page 5: ...Belastungen bis max 5 A Front Hinweis Die maximale Strombelastung beträgt 60A P 1570 30 A P 1580 AUX Hauptausgang 7 Anschlüsse des Hauptausgangs an der Rückseite für Strombelastungen bis 60 A P 1570 bzw 30 A P 1580 8 Remote Sensing Fernabtastung Anschlüsse nur P 1570 9 Auswahlschalter für Modus Normal Preset Remote Control oder Set 10 Recall Auswahlschalter zur Auswahl von 3 verschiedenen Festspan...

Page 6: ...rom des Schaltnetzteiles benötigen Bei Nichtbeachtung besteht die Gefahr der Beschädigung des Schaltnetzteils vor dem Auswechseln einer defekten Sicherung Ursache des Defektes bestimmen und defekte Sicherung nur mit einer dem Originalwert entsprechenden Sicherung ersetzen P 1565 1575 1585 T4AL250V P 1570 1580 T8AL250V bei Schäden am flexiblen Anschlusskabel des Netzgerätes neues Kabel nur beim Her...

Page 7: ...onen Die folgenden Schritte erklären wie die zusätzlichen Funktionen Remote Sensor und Fernsteuerung zu benutzen sind Es ist möglich beide Funktionen zeitgleich zu verwenden oder separat voneinander Wenn diese Funktionen nicht benötigt werden muss sichergestellt sein dass der Schalter remote control an der Rückseite des Gerätes sich auf der Stellung OFF befindet 6 1 Remote Sensing Fernabtastung P ...

Page 8: ...werden über Doppelfunktionsregler eingestellt Drücken Sie die Regler um zwischen Grob und Feineinstellung zu wechseln Beachten Sie dabei die leichten Änderungen in der Helligkeit des jeweiligen Displays Stellen Sie die Regler durch Grob und Feineinstellung auf die gewünschten Werte ein Zur Prüfung des eingestellten Stroms leicht den Stromregler in beliebiger Richtung drehen Das Display kehrt zur B...

Page 9: ...nung ein 3 Stellen Sie mit dem CURRENT Regler den gewünschten maximalen Ausgangsstrom ein 4 Wiederholen Sie den Vorgang gegebenenfalls für die verbleibenden Positionen P1 P2 oder P3 5 Stellen Sie zur Bestätigung Ihrer Einstellungen den Modusschalter von Set auf Preset Hinweis Alle im Preset Modus eingestellten Werte bleiben auch nach Abschalten des Geräts erhalten Prüfen Sie stets die Ausgangsspan...

Page 10: ... halten Sie den Spannungsregler für 30s um den MENU Modus zu aktivieren Wird CCO angezeigt drehen Sie den Spannungsregler bis rPr angezeigt wird Die Stromanzeige zeigt nun no an Drehen Sie den Stromregler bis YES angezeigt wird Drücken Sie nun den Stromregler um zu bestätigen Die YES anzeige leuchtet nun auf und die Voreinstellungen werden auf den Ursprungswert zurückgesetzt Abschließend drücken S...

Page 11: ...manuell durchgeführt werden Drücken und halten Sie den Spannungsregler für 30s um den MENU Modus zu aktivieren Anzeige Drehen Sie den Stromregler bis das Gerät folgendes anzeigt Drücken Sie nun den Stromregler einmal zur Bestätigung Bei erfolgreicher Nullstellung wird YES angezeigt Drücken Sie nun den Spannungsregler um den MENU Modus zu verlassen 6 6 Remote Control Modus Zum Steuern von Ausgangss...

Page 12: ...f der Vorderseite leuchten abwechselnd Beim Prüfen des Lüfters sind durch hohe Geschwindigkeit hervorgerufene Windgeräusche zu hören Nach den Selbsttests leuchten die CV LED Volt und Ampere Display und zeigen die Spannung sowie 0 0 Strom an Zur Überprüfung des eingestellten Stromwertes drehen Sie den CURRENT Regler einen Klick nach rechts oder links Das Strom Display schaltet nach einigen Sekunden...

Page 13: ...erät ein 8 5 Sie können nun das externe Gerät verwenden und damit arbeiten 8 6 Nach Beendigung der Messarbeiten schalten Sie zuerst das extern verbundene Gerät aus und danach das Netzgerät 9 Fernsteuerung 9 1 Fernsteuerung P 1565 1575 Es stehen zwei Methoden zur Fernsteuerung von Strom und Spannungseinstellung zur Verfügung Beide Methoden erfordern die Stromfernsteuerung damit der Fernsteuerungsmo...

Page 14: ...s 3 Stromeinstellung Schleiferkontakt des Potentiometers 4 Ground Anderes Potentiometer Ende 5 Ausgang Aus mit Ground kurzschließen 6 N A 7 N A 8 N A Überprüfen Sie den gesamten Ausgangsspannungsbereich der Spannungsquellen indem Sie die Spannungen der externen Spannungsquellen verändern Schließen sie den Haupt Ausgang mit einer 12AWG 3 3mm2 Leitung kurz um die CC Mode Einstellungen zu überprüfen ...

Page 15: ...tromeinstellung per Drehregler ändern Hinweis Verwenden Sie den im Lieferumfang enthaltenen 8 PIN Remote Stecker und verbinden Sie ihn mit einer 22AWG 0 33mm2 Leitungen 9 3 Fernsteuerung P 1570 1580 Die Spannungs und Stromfernsteuerung können separat gleichzeitig genutzt werden Vorbereiten des im Lieferumfang befindlichen Remote Steckers zur Fernsteuerung der Spannungskontrolle a Lösen Sie die Sch...

Page 16: ...rd in den Remote Anschluss gespeist um den Ausgangsspannungspegel einzustellen ACHTUNG Keine Spannung 5 V an den Remote Anschluss anlegen ansonsten löst der Überspannungsschutz des Gerätes aus 1 Stellen Sie sicher dass das Netzgerät ausgeschaltet und die Last vom Gerät getrennt ist 2 Verwenden Sie nur die Leitungen des PIN 2 und 4 Verbinden Sie die Leitung von PIN 2 an den positiven Pol und die Le...

Page 17: ...euerung der Spannungskontrolle Vorbereiten des im Lieferumfang befindlichen Remote Steckers a Verwenden Sie den gleichen Remote Stecker wie schon in Punkt 1 beschrieben und entfernen Sie das schwarze Oberteil wie beschrieben 1 Lösen der Schraube 2 Drehen des schwarzen Oberteils 3 schwarzen und silbernen Teil des Remote Steckers trennen b Löten Sie drei Leitungen 22AWG 0 33mm2 an PIN 1 3 und 4 des ...

Page 18: ...Keine Spannung 5V an den Remote Anschluss anlegen ansonsten könnte das Gerät beschädigt werden 1 Stellen Sie sicher dass das Netzgerät ausgeschaltet und die Last vom Gerät getrennt ist 2 Verwenden Sie nur die Leitungen des PIN 3 und 4 Verbinden Sie die Leitung von PIN 3 an den positiven Pol und die Leitung des PIN 4 an den negativen Pol der externen Spannungsquelle 3 Verwenden Sie eine 8AWG 8 35mm...

Page 19: ...und die Leitung des PIN 4 an den negativen Pol der externen Spannungsquelle 3 Verwenden Sie eine 8AWG 8 35mm2 Leitung um den Hauptausgang an der Rückseite des Gerätes kurz zu schließen 4 Schalten Sie das Netzgerät ein 5 Drehen Sie das Potentiometer von einem Anschlag zum anderen zur Überprüfung des vollen Ausgangsspannungsbereiches 6 Schalten Sie das Netzgerät aus und entfernen Sie die Kurzschluss...

Page 20: ...squellen verändern Schließen sie den Hauptausgang des Netzgerät es mit einer 8AWG 8 35 mm2 Leitung kurz um die CC Mode Einstellungen zu überprüfen während Sie die externen Spannungswerte verändern Methode B Verwenden Sie zwei 0 5kOhm Potentiometer Hinweis Potentiometer 5kOhm Überprüfen Sie den gesamten Ausgangsspannungsbereich der Spannungsquellen indem Sie die Spannungen der externen Spannungsque...

Page 21: ...2 3 dgt Stromanzeige 3 stellige LED Anzeige 0 2 3 dgt Allgemein Eingangsspannung 220 240V AC 50 60Hz Max Eingangsstrom 3 15A 4 7A 3 1A 4 5A 4 5A Effizienz 85 50 85 00 87 00 86 00 88 Schaltfrequenz 65 85kHz 65 85kHz 75 85kHz 75 95kHz 65 85kHz Transiente Ansprechzeit 50 100 1 5ms Leistungsfaktorkontrolle PFC Leistungsfaktorkorrektur 0 95 bei optimaler Last Kühlung Temperaturgesteuerter Lüfter Schutz...

Page 22: ...f Bleibt das Problem bestehen wenden Sie sich bitte an Ihren Fachhändler 11 2 OTP Übertemperaturschutz Das Gerät verfügt über einen Thermo Sensor der die Temperatur im Innern des Geräts überwacht Im Falle von Übertemperatur wird keine Leistung mehr abgegeben und folgende Warnmeldung erscheint im LED Display Bei Erscheinen dieser Warnmeldung schalten Sie das Gerät aus und entfernen Sie alle Lasten ...

Page 23: ...k oder der angeschlossen Last kommen Der OLP dient zur Minimierung von Schäden bei Ihren angeschlossen Lasten sollte das Netzgerät eines Tages ausfallen Schalten Sie das Netzgerät aus sobald Sie die unten abgebildete Warnmeldung sehen Zum Zurücksetzen der Warnmeldung schalten Sie das Gerät aus und entfernen Sie alle Lasten Schalten Sie das Gerät wieder ein und überprüfen Sie sein Funktionieren mit...

Page 24: ...feld Zur Änderung der allgemeinen Einstellungen des Programms und der Darstellung des Datenprotokolls 3 Ausgangsstuerung Einstellung der Ausgangssteuerung ON OFF bzw der Ausgangswerte 4 Menüleiste Zum Speichern Öffnen und Drucken von Datensätzen 5 Eingabefeld für External Timed Programmbeschreibung Zur Eingabe der Beschreibung für External Timed Programme einzugeben 6 Programmeinstellung Einstellu...

Page 25: ...usgangsstrom direkt einzugeben und dann durch klicken auf Set zu übernehmen oder mit Hilfe des Schiebereglers die Werte einzustellen 24 Die Anzeige zeigt folgende Informationen Wert der Ausgangsspannung aktuelle Ausgangswerte Ausgangswert der Leistung Output On Off Status C V C C Modus eingestellte Werte ...

Page 26: ...orgung Wählen Sie die External Timed Program Registerkarte um auf die External Timed Program Registerkarte zu wechseln Doppelklick auf die Zelle dessen Wert verändert werden soll Zum Beispiel Zeile 2 Spannung Balken auf den gewünschten Wert schieben Stellen Sie für diesen Schritt die Zeit ein wie lange dieser Schritt ausgeführt werden soll Einstellbar zwischen 0 bis 9 Stunden 59 Minuten und 59 Sek...

Page 27: ...ogrammdurchlauf zwischen 0 999 mit Hilfe des Schiebereglers oder direkt über das Textfeld einen Wert einzugeben Eingabe 0 bedeutet das Programm unendlich auszuführen Schaltfläche drücken um den Programmzyklus zu starten Während das Programm durchläuft die Schaltfläche drücken um den Programmdurchlauf anzuhalten Schaltfläche drücken um Einstellungen zurückzusetzen 12 5 Interner Speicher für Voreins...

Page 28: ...fgerufene Daten werden in roter Farbe dargestellt wenn sie die vorgegebenen Grenzwerte für Spannung und Strom überschreiten Claer Table Löschen aller Daten auf dem Display Table bereit für neue Dateneingabe Read From PS Sie Daten aus dem Netzteil 12 6 Data Log Data Log Fenster Das Data Log Fenster dient der Anzeige von Spannung Strom und Leistung über eine Zeit in der grafischen Ansicht Sie können...

Page 29: ...en Sie hierzu die Registerkarte Main configure oder Data Log Wenn die External Timed Program Registerkarte ausgewählt wird werden die Tasten zum Speichern und Laden der Einstellung von External Timed Program verwendet Schaltfläche drücken um die External Timed Program Einstellungen in eine CSV Datei zu speichern Schaltfläche drücken um die CSV Datei zu öffnen und mit den gespeicherten Einstellunge...

Page 30: ...Registerkarte Setting können allgemeine Einstellung für das Programm durchgeführt werden die Sprache für das Programm auswählen COM Port für das verbundene Labornetzgerät auswählen Abtastzeit für das Datenprotokoll mit Hilfe des Schiebereglers setzen Grenzwert für die Ausgangsspannung UVL einstellen um angeschlossene Niederspannungs Anwendungen zusätzlich vor Beschädigungen zu schützen Grenzwert f...

Page 31: ...ng Switch on the output of PS Input Command VOLT voltage CR Return value OK CR Preset Voltage value voltage 000 Max Volt Max Volt value refer to product specification Input command VOLT127 CR Return value OK CR Meaning Set Voltage value as 12 7V Input Command CURR current CR Return value OK CR Preset Current value current 000 Max Curr Max Curr value refer to product specification Input command CUR...

Page 32: ...0 as 11 1V and 11 1A Preset Memory 1 as 2 2V and 12 2A Preset Memory 2 as 3 3V and 13 3A Input Command GETM CR Return value voltage0 current0 CR voltage1 current1 CR voltage2 current2 CR OK CR Get saved Voltage and Current value from 3 PS memory locations voltageX currentX X is memory location number start from 0 to 2 Input command GETM CR Return value 111111 CR 122122 CR 133133 CR OK CR Meaning P...

Page 33: ...n Input command SOVP151 CR Return value OK CR Meaning Preset upper limit of output Voltage as 15 1V Input Command GOCP CR Return value current CR OK CR Get preset upper limit of output Current current Input command GOCP CR Return value 111 CR OK CR Meaning The preset upper limit of output Current is 11 1A Input Command SOCP current CR Return value OK CR Preset upper limit of output Current current...

Page 34: ...Verfahren nur mit schriftlicher Genehmigung des Herausgebers gestattet Letzter Stand bei Drucklegung Technische Änderungen des Gerätes vorbehalten Hiermit bestätigen wir dass alle Geräte die in unseren Unterlagen genannten Spezifikationen erfüllen und werkseitig kalibriert geliefert werden Eine Wiederholung der Kalibrierung nach Ablauf von einem Jahr wird empfohlen PeakTech 07 2015 Po 33 ...

Page 35: ...ower supply Never use the power supply for the load requiring higher current than the designed value otherwise it may damage the power supply Replace a defective fuse only with a fuse of the original rating Never short circuit fuse or fuse holding To avoid electric shock do not operate this product in wet or damp conditions Conduct measuring works only in dry clothing and rubber shoes i e on isola...

Page 36: ...as protective functions against short circuit and overload but it is not a protection against inductive reverse voltages which can be caused by electric motors or batteries 2 Features Lightweight and Small Size Switching mode power supply has the advantages of lightweight and small size Comparing with linear mode power with the same power output it is much lighter and smaller High Efficiency The u...

Page 37: ...ntrol both the main and auxiliary output current limit 5 Power ON OFF Switch 6 Aux output terminal max 5A Note The total rated current is 40 A P 1565 20 A P 1575 15 A P 1585 Aux Main 7 Output Terminal 8 Mode Selection Switch Normal Preset Remote Control Set Modes 9 Recall Selection Switch 10 Remote Control Terminal 11 Cooling Fan Air Intake Grille 12 AC Input Plug 13 USB port For access to compute...

Page 38: ...n and auxiliary output current limit 5 Power ON OFF Switch 6 Aux output terminal max 5A Note The total rated current is 60 A P 1570 resp 30 A P 1580 Aux Main 7 Output Terminal 8 Remote Sensing Terminal P 1570 only 9 Mode Selection Switch Normal Preset Remote Control Set Modes 10 Recall Selection Switch 11 Remote Control Terminal 12 Cooling Fan Air Intake Grille 13 AC Input Plug 14 USB port For acc...

Page 39: ...anufacturer or his service agent 5 1 Safety Precautions Never touch the unit when your hands are wet Never operate the unit if foreign materials such as metallic objects water or other debris have fallen inside Contact your dealer for check and repair Never allow foreign objects to touch the DC Power Output Terminals Laboratory Power Supplies are not designed for charging batteries Any use of this...

Page 40: ...wire should be AT LEAST 22 AWG 0 33 mm wire size Disconnection Wrong disconnect sequence will damage power supply 1 First disconnect the remote sensing connections 2 Then disconnect the power connections between the power supply and equipment 6 2 Control Mode Selection There are 4 modes Normal Preset Set and Remote Control mode for the power supply Slide the Mode Selection Switch 8 P 1565 1575 158...

Page 41: ...ply is then ready to be preset 6 5 1 To define the preset output P1 P2 P3 1 Select the Recall Switch to the position P1 P2 or P3 which you want to set 2 Adjust the front panel voltage control knob to set your desired voltage value 3 Adjust the front panel current control knob to set your desired current limit value 4 Repeat the procedure for remaining recalls P1 P2 P3 if desired 5 Move Mode Switch...

Page 42: ...d hold Voltage Control Knob for 30s to enter MENU mode When it is showing CCO rotate Voltage Control Knob until Voltage meter showing rPr The Current meter is showing no at this time Then rotate Current Control Knob until Current meter showing YES Press Current Control Knob once to confirm The YES will be lighted after preset output being reset to factory default value Finally press Voltage Contro...

Page 43: ...nually reset it to zero in menu mode Press and hold Voltage Control Knob for 30s to enter MENU mode It shows Rotate Current Control Knob until the Current meter showing Then press Current Control Knob once to confirm The YES will be lighted after successful zeroing current meter offset Finally press Voltage Control Knob to exit MENU mode 6 6 Remote Control Mode To control the output voltage and cu...

Page 44: ... other indicators on the front panel will be on by turn When the cooling fan is being checked a high speed wind noise can be heard After the self checks the CV V and A LED indicators are lit up displaying voltage and 0 0 current To find out about the set CC current level just turn the current control knob one click in either direction The current display returns to 0 0 after a few seconds Below ta...

Page 45: ...pment When an operation is finished switch off the equipment first and then switch off the power supply 9 Remote Control Mode 9 1 Remote Control Mode P 1565 1575 1585 There are two methods for remote control of current and voltage adjustment Both methods require current remote control part to be set up in order for remote control mode to be functional otherwise unit will be in CC mode all the time...

Page 46: ...sistor 3 Current Adjust Variable part of resistor 4 Ground Another resistor end 5 Output OFF Short to Ground 6 N A 7 N A 8 N A CC current setting by remote control Short circuit the main output with 12AWG 3 3mm2 wire Adjust the CC current setting using the 0 5k Ohm variable resistor Output voltage setting by remote control Check the output voltage range of the power supply by adjusting the 5Kohm v...

Page 47: ...age current control knob to your desired value when output is off Remark using the 8pin remote plug provided and connect with 22AWG 0 33mm2 wires 9 3 Remote Control PeakTech 1570 1580 You can use the voltage and current remote control at the same time or separately Set up the provided remote connector plug a Remove the black portion of the remote control connector plug by removing the screw 1 Remo...

Page 48: ...ure the load is disconnected and the power supply is OFF 2 Use Only wires from port 2 and 4 Then connect port 2 to positive polarity of the external voltage source and port 4 to negative polarity of the external voltage source 3 Switch on the power supply 4 Vary the external input voltage 0 5 V to check and verify for the full output voltage range of power supply 5 Switch off the power supply Meth...

Page 49: ...lder 3 wires 22AWG 0 33mm2 to PORT 1 3 4 of black portion as shown c Make sure the load is disconnected and the power supply is OFF d Plug the remote connector plug into the remote control terminal of the power supply e Secure the remote connector plug to the terminal socket by locking connector ring Outer ring Then you can choose either method A or B below to use the remote control feature 48 Por...

Page 50: ...l in the rear panel 4 Switch on the power supply 5 Vary the external input voltage 0 5 V to check and verify for the full output current range of power supply 6 Switch off the power supply and disconnect the 8AWG 8 35mm2 wire Method B Using 5 kΩ Variable Resistor 1 Make sure the load is disconnected and the power supply is OFF 2 Prepare a 5 kΩ variable resistor and use wires from port 1 3 and 4 3 ...

Page 51: ...oltage range of the power supply by varying the external voltage source Short circuit the main output with 8AWG 8 35mm2 wire to check the display for CC setting varying the external voltage source Method B Using two 0 5K Ohm variable resistors Remark variable resistors 5KOhm PIN Function Remarks 1 Internal DC 5V Resistor end 2 Voltage Adjust Variable part of resistor 3 Current Adjust Variable part...

Page 52: ... Meter 3 stellige LED Anzeige 0 2 3 dgt General Input Voltage 220 240V AC 50 60Hz Full Load Input current 3 15A 4 7A 3 1A 4 5A 4 5A Efficiency 85 50 85 00 87 00 86 00 88 Switching Frequency 65 85kHz 65 85kHz 75 85kHz 75 95kHz 65 85kHz Transient Response Time 50 100 Load 1 5ms Power Factor Control PFC Power Factor Correctionr 0 95 at optimal Load Cooling Method Thermostatic Control Fan from Zero to...

Page 53: ...d consult with your agent 11 2 OTP Over Temperature Protection There is a thermo sensor inside the unit to monitor and to prevent the unit to gets too hot inside At OTP there is no output and the following warning will appear on the LED display When you get this warning switch off the unit and remove all loading Check your load and output setting Allow the unit to cool down for at least 30 minutes...

Page 54: ...est piece or load The OLP is to minimize the extent of damage to your loads as power supplies do fail some day Switch off your power supply as soon as you see this warning as shown below To reset this warning switch off the unit and remove all loading Switch the unit back on again and double check with caution If this problem cannot be fixed please contact and consult with your agent 53 ...

Page 55: ... log display panel use to change general setting of program and display data log 3 Voltage and Current setting panel use to set incident output value and output On Off 4 Data handling panel use to save load and print data 5 External Timed Program Description input space use to enter description of External Timed Program 6 Program running cycle setting panel use to set running cycle for External Ti...

Page 56: ...the desired output voltage output current and then click Set button to set the value Or you can use slide bar to adjust the value 55 The display show following information Output Voltage value Output Current value Output Power value Output On Off status C V C C Model Setting values ...

Page 57: ...switch to the External Timed Program tab Double click on the cell that you would like to set value For example Step 2 voltage Slide the bar to configure the value Set time for this step to be running The time range is between 0 to 9hours 59 minutes 59 seconds You can click up down button to change value or directly input value If the time value is set to 0 this step will be skipped 56 ...

Page 58: ...lide bar to select or directly input value in text box Input 0 means run the program forever Click on button to start running cycle In between program running cycle click button to stop program Click to clear the setting 12 5 Internal Preset Memory 57 ...

Page 59: ...rthermore retrieved data will be in red color if they exceed the present preset limits of voltage in upper voltage level or current limiting value Clear Table Delete all data on the Display Table to ready for new data entry Read for PS Get data from the Power Supply 12 6 Data Log Data Log window Data log window is used to display output Voltage Current and Power against time in graphical view You ...

Page 60: ...d and print setting for External Timed Program and Internal Preset Memory First select tab in Main configure and data log display panel When External Timed Program tab is being selected the buttons are used to save and load the setting of External Timed Program Click to save External Timed Program setting to CSV file Click to open and load setting from CSV file to program Click to print the settin...

Page 61: ...setting to print 12 8 Setting In the setting page you can do general setting for the program You can select language for the program You can select the COM Port for power supply connected You can set sampling time for data log by adjust slide bar You can set your output voltage upper limit UVL value to further safeguard your low voltage applications You can set your output current upper limit UCL ...

Page 62: ...g Switch on the output of PS Input Command VOLT voltage CR Return value OK CR Preset Voltage value voltage 000 Max Volt Max Volt value refer to product specification Input command VOLT127 CR Return value OK CR Meaning Set Voltage value as 12 7V Input Command CURR current CR Return value OK CR Preset Current value current 000 Max Curr Max Curr value refer to product specification Input command CURR...

Page 63: ...0 as 11 1V and 11 1A Preset Memory 1 as 2 2V and 12 2A Preset Memory 2 as 3 3V and 13 3A Input Command GETM CR Return value voltage0 current0 CR voltage1 current1 CR voltage2 current2 CR OK CR Get saved Voltage and Current value from 3 PS memory locations voltageX currentX X is memory location number start from 0 to 2 Input command GETM CR Return value 111111 CR 122122 CR 133133 CR OK CR Meaning P...

Page 64: ...n Input command SOVP151 CR Return value OK CR Meaning Preset upper limit of output Voltage as 15 1V Input Command GOCP CR Return value current CR OK CR Get preset upper limit of output Current current Input command GOCP CR Return value 111 CR OK CR Meaning The preset upper limit of output Current is 11 1A Input Command SOCP current CR Return value OK CR Preset upper limit of output Current current...

Page 65: ...al knowing Technical changing which are in the interest of progress reserved We herewith confirm that the units are calibrated by the factory according to the specifications as per the technical specifications We recommend to calibrate the unit again after one year PeakTech 07 2015 Po PeakTech Prüf und Messtechnik GmbH Kornkamp 32 DE 22926 Ahrensburg Germany 49 0 4102 42343 44 49 0 4102 434 16 inf...