background image

9

Para Reinicializar el In

versor

1. 

Apague el In

versor

 usando el interruptor ON/OFF en el 

Inversor

 o el botón ON/OFF del 

interruptor remoto

, dependiendo de como estaba siendo controlado el In

versor

.

2. 

Desenchufe todos los apar

atos conectados al In

versor

.

3. 

Encienda de nue

vo el 

Inversor

 usando el interruptor de ON/OFF en el 

Inversor

 o el botón  

ON/OFF del interruptor remoto

.

4. 

Antes de reconectar los dispositivos al In

versor

, ver

ifique el vatiaje total de los dispositiv

os con el 

fin de asegurarse de que sean menos de la capacidad del In

versor

.

Protección 

de Temperatura

El Inversor está equipado con un v

entilador. Dependiendo de la carga de salida y de la temper

atura 

del Inversor

, el ventilador se encenderá y se apagará como sea necesar

io para enfr

iar el Inversor

.

Si la temperatur

a alcanza aproximadamente 149°F (65°C) el In

versor se apagará automáticamente

Apague el Inversor y déjelo que se enfríe dur

ante un mínimo de 15 minutos

. Antes de arr

ancarlo de

 

nue

vo, v

erifique el v

atiaje total de los dispositivos que serán alimentados

.

Prob

lemas Comunes

Las herramientas motorizadas arrancarán pero no contin

uarán funcionando

 - Algunos 

motores de inducción (motores sin escobillas) podrán necesitar de 2 a 6 veces más v

atiaje para que

 

arranquen.

 Si la herramienta motor

izada trabaja momentáneamente cuando se le aplica energía,

 

trate de dejar la herr

amienta prendida mientras que repetidamente prende y apaga el In

versor

.

Zumbido en los sistemas de audio

 - Algunos sistemas estéreo baratos emitirán un zumbido por

 

los parlantes cuando son oper

ados en el Inversor

. Esto es causado por que la fuente de energía del

 

aparato no filtr

a adecuadamente la onda senoidal modificada producida por el Inversor

.

Interferencia con la tele

visión

 - El Inversor es b

lindado y filtrado par

a minimizar la interferencia

 

con las señales de televisión.

 En algunos casos, especialmente con señales de tele

visión débiles, se

 

puede ver alguna interf

erencia. T

rate las siguientes medidas correctiv

as:

• 

  Coloque el In

versor tal lejos como sea posib

le de la televisión, antena y del cab

le de la antena.

• 

  Ajuste la or

ientación del Inversor

, del cable de la antena y del cab

le de energía de la televisión

 

para minimizar la interf

erencia.

• 

  Use cab

le de antena blindado de alta calidad.

Operación de un microonda

 - La capacidad de energía usada en los hornos microonda es la

 

“potencia de cocción” que califica como la energía que se esta 

“entregando” a los alimentos que

 

se están cocinando en el microondas. La capacidad requer

ida de energía de operación es más

 

alta que la capacidad de energía para cocinar

. Esto es usualmente mencionado en la par

te traser

del microondas. Si no puede ubicar el requisito de energía de oper

ación en la parte tr

asera del

 

microonda, consulte el manual del propietar

io o póngase en contacto con el fabr

icante.

CUIDADOS Y 

MANTENIMIENTO

Almacenaje

Almacene este Inversor de Energía en una área fría y seca, alejado de la luz solar directa, el calor y

 

la humedad excesiv

a. La temper

atura de almacenaje debe ser entre –4° y 185°F (–20° y 85°C) con

 

una humedad entre el 10% y el 90%.

Limpieza

No limpie o le pase un trapo con disolv

entes o materiales químicos al In

versor de Energía.

 Si es 

necesario

, remue

va la m

ugre o las manchas con un tr

apo suave humedecido en una solución de

 

detergente suave

.

Descarte

 

El Inversor de Energía fue diseñado par

a proporcionarle años de ser

vicio. Puesto que el

 

Inversor y los cab

les pueden contener plomo, ellos deberán ser reciclados o descar

tados 

seguramente en un centro de reciclaje local.

 Ejemplos de lugares que aceptan artículos

 

como estos son: centros de reciclaje del condado

, municipales o distr

ibuidores de

 

chatarra.

9

To Reset the Inverter

1.  Turn off the Inverter using the ON/OFF switch on the Inverter or the remote switch ON/OFF 

button, depending upon how the Inverter was controlled.

2.  Unplug all the devices from the Inverter.

3.  Turn the Inverter back on using the ON/OFF switch on the Inverter or the remote switch ON/OFF 

button.

4.  Before devices are reconnected to the Inverter, verify the total wattage of the devices to ensure 

they are less than the rating of the Inverter.

Temperature Protection

The Inverter is equipped with a cooling fan. Depending upon the load output and the temperature of 

the Inverter, the cooling fan will turn on and off as required to cool the Inverter if needed.
If the temperature reaches approximately 149°F (65°C) the Inverter will shut down automatically. Turn 

off the Inverter and allow it to cool for a minimum of 15 minutes. Before starting up again verify the 

total wattage of the devices being powered.

Common Problems

Power tools will start but will not continue to run

 - Some induction motors (motors without 

brushes) may require 2 to 6 times their wattage rating in order to start up. If the power tool runs 

only momentarily when power is applied, try to leave the power tool on while quickly and repeatedly 

turning the Inverter on and off.

Buzzing in audio systems

 - Some inexpensive stereo systems will emit a buzzing sound from their 

speakers when operating from the Inverter. This is because the power supply in the device does not 

adequately filter the modified sine wave produced by the Inverter.

Television interference

 - The Inverter is shielded and filtered to minimize interference with TV 

signals. In some cases, especially with weak TV signals, some interference may be visible. Try the 

following corrective measures:

• 

 Position the Inverter as far away as possible from the television, the antenna and the antenna 

cable.

• 

 Adjust the orientation of the Inverter, the antenna cable and the TV power cable to minimize 

interference.

• 

 Use high-quality, shielded antenna cable.

Operating a microwave

 - The power rating used with microwave ovens is the “cooking power” which 

qualifies as the power being “delivered” to the food being microwaved. The actual operating power 

requirement rating is higher than the cooking power rating. This is usually referenced on the back of 

the microwave. If the operating power requirement cannot be found on the back of the microwave, 

check the owner’s manual or contact the manufacturer.

CARE AND MAINTENANCE

Storage

Store this Power Inverter in a cool, dry area and keep it away from direct sunlight, heat, excessive 

humidity and dampness. Storage temperature should be between -4°F and 185°F (-20°C and 85°C) 

with the humidity between 10% and 90%.

Cleaning

Do not clean or wipe the Power Inverter with solvents or chemical materials. If necessary, remove dirt 

or stains using a soft cloth dampened with a mild detergent solution.

Disposal

 

The Power Inverter is designed to provide years of service. Because the Inverter and 

cables may contain lead, they should be recycled or safely disposed of at a local 

recycling center. Examples of places that will accept items like this are: county or 

municipal recycling drop-off centers or scrap metal dealers.

Summary of Contents for PKC0AX

Page 1: ...estas instrucciones antes de usar este producto Conserve este Manual del Propietario para referencia futura 9 13 1 2013 2000 Watt Power Inverter Model No PKC0AX Owner s Manual and Warranty Information...

Page 2: ...ed in any other way 2 NDICE PRECAUCIONES DE SEGURIDAD 2 Seguridad del Inversor de Energ a 2 INTRODUCCI N 3 CARACTER STICAS 3 OPERACI N USO DE SU INVERSOR 3 C mo Determinar el Consumo de Energ a Consum...

Page 3: ...Algunos hornos y estufas de aglomerados con control por microprocesador Radios y relojes digitales Maquinas de coser con control de velocidad por microprocesador Electr nica que modula se ales de frec...

Page 4: ...cargadores de bater as para bater as de n quel cadmio se pueden da ar si son enchufados en el Inversor Los siguientes electrodom sticos o dispositivos se pueden da ar si son enchufados en el Inversor...

Page 5: ...CA o donde el conductor neutro est conectado al terminal negativo de una fuente de energ a CC El conectarlo a estos circuitos podr causarle da os al Inversor y o crear una chispa 5 To increase the ope...

Page 6: ...s de tornillo para sujetar los cables al Inversor El rojo es positivo y el negro es el negativo 1 Oprima el interruptor de ON OFF y el bot n del interruptor remoto ON OFF a la posici n OFF 2 Remueva l...

Page 7: ...ha sido encendido usando el interruptor remoto la operaci n del Inversor ser controlada usando el interruptor remoto 5 Apague el Inversor usando el interruptor remoto antes de desconectar el conector...

Page 8: ...lida que indica cuanto vatiaje est siendo usado El indicador de potencia de salida tiene diez luces separadas cuando se prenden cada una representa aproximadamente 200 vatios de salida Si el dispositi...

Page 9: ...para proporcionarle a os de servicio Puesto que el Inversor y los cables pueden contener plomo ellos deber n ser reciclados o descartados seguramente en un centro de reciclaje local Ejemplos de lugar...

Page 10: ...os s ntomas b sicos La unidad est equipada con un dispositivo de auto protecci n para ayudar a evitar da os en el tomacorriente m vil y en los accesorios que est n siendo energizados por l No hay fusi...

Page 11: ...i n de Alambrado Directo 300 amperios ANL 22 Requisitos del Cable 6 pies 1 8 m 2 AWG Calibre de Cable Americano 23 Requisitos del Cable 10 pies 3 0 m 00 AWG Calibre de Cable Americano 24 Dimensiones L...

Page 12: ...o hay salida de energ a Mala conexi n Apague el interruptor de energ a del Inversor verifique que los cables est n conectados firmemente en el Inversor y en la fuente de energ a Voltaje de la bater a...

Page 13: ...echa de compra PEAK y la gr fica de la Monta a PEAK son marcas registradas de Old World Industries LLC Northbrook IL 60062 Todos los derechos reservados FABRICADO EN CHINA www peakauto com 13 LIMITED...

Page 14: ......

Reviews: