background image

Via the

Error Generator

tab the communication on the CAN bus in test environments

or during the development of CAN buses can be disturbed in a controlled way by 6
consecutive dominant bits. This is a violation of the CAN protocol on the CAN bus
which must be recognized as an error by the connected CAN nodes.

Note:

The Error Generator should only be used by experienced users

and in the development environment. For further information, please
contact our customer support:

[email protected]

You can destroy CAN frames with the error generator by one of two methods:

once after activation

repeatedly at specific intervals related to a CAN ID

5 CAN Monitor PCAN-View

PCAN-PCI Express

User Manual 4.0.0

© 2022 PEAK-System Technik GmbH

22

Summary of Contents for IPEH-003026

Page 1: ...PCAN PCI Express User Manual User Manual 4 0 0 2022 PEAK System Technik GmbH...

Page 2: ...ames in this document may be the trademarks or registered trademarks of their respective companies They are not explicitly marked by or 2022 PEAK System Technik GmbH Duplication copying printing or ot...

Page 3: ...ecting the CAN Bus 12 4 1 Connection over D Sub connector 12 4 2 Cabling 13 4 3 Example Application under Windows 14 5 CAN Monitor PCAN View 15 5 1 CAN Interface initialize 16 5 2 Transmit CAN message...

Page 4: ...t of applications with CAN connection are included in the scope of supply Device drivers exist for different operating systems so programs can easily access a connected CAN bus This manual describes t...

Page 5: ...Sub 9 pin in accordance with CiA 303 1 FPGA implementation of the CAN controller SJA1000 compatible NXP PCA82C251 CAN transceiver Galvanic isolation up to 500 V per CAN connection Power supply for ext...

Page 6: ...press Slot bracket with D Sub connectors for the CAN bus only quad channel Downloads Device drivers for Windows 11 10 32 64 bit and Linux 32 64 bit CAN monitor PCAN View for Windows Programming interf...

Page 7: ...for Low speed CAN Pin 1 is not assigned at delivery The current output is limited to 50 mA 2 1 1 Activate Voltage Supply Risk of short circuit Soldering on the CAN interface may only be performed by q...

Page 8: ...t default Active Pin 1 CAN 1 JP100 CAN 2 JP200 CAN 3 JP300 CAN 4 JP400 Attention The voltage supply for external devices is not protected separately Therefore turn off the computer before you connect...

Page 9: ...all the driver before you install the CAN interface 3 1 Install Device Driver Setup 1 Download the device driver setup from our website www peak system com quick DL Driver E 2 Unpack the file PEAK Sys...

Page 10: ...ress slot and attach it to the slot 5 Quad channel Connect one cable per CAN connection from the slot bracket to a 10 pin male connector on the plug in card CAN 3 and CAN 4 6 Quad channel Insert the s...

Page 11: ...or when the card is in a PEG slot You can ensure correct recognition of the card by changing the settings in the computer BIOS Make the following settings in the BIOS of your computer mainboard 1 For...

Page 12: ...nector The pin assignment of the D Sub connector corresponds to the specification CiA 303 1 10 pin connector on the plug in card D Sub plug CAN 1 to 4 Assignment 1 1 5 V optional 2 6 CAN_GND 3 2 CAN_L...

Page 13: ...N interface PCAN PCI Express does not have an internal termination Use the CAN interface on a terminated CAN bus 4 2 2 Example of a Connection This example shows a connection between the PCAN Interfac...

Page 14: ...bit s 3 3 km 10 kbit s 6 6 km 5 kbit s 13 km The listed values have been calculated on the basis of an idealized system and can differ from reality 4 3 Example Application under Windows As an example...

Page 15: ...talled with the installation of the device driver package under Windows In the following the initialization of a CAN interface is described as an example Detailed information about using PCAN View can...

Page 16: ...try in Available Hardware USB Interface 1 channel see example above USB Interface 2 channel PCIe Interface 2 channel 2 If there are several CAN Interfaces select the desired interface For multiple cha...

Page 17: ...ain window appears and displays the Receive Transmit tab 5 For initializing another channel or CAN Interface open another instance of PCAN View 5 CAN Monitor PCAN View PCAN PCI Express User Manual 4 0...

Page 18: ...e field to choose manually or periodically message transmission Enter a value greater than 0 to transmit periodically Enter the value 0 to transmit only manually 3 Confirm the entries with OK The crea...

Page 19: ...l tabs are available 5 3 1 Trace Tab The tracer data logger records the communication of the CAN bus in linear or ring buffer mode The trace data can be saved to a file 5 CAN Monitor PCAN View PCAN PC...

Page 20: ...for the PCAN miniPCIe FD Depending on the CAN interface a hardware ID can be determined to distinguish several interfaces of the same type For interfaces with CAN FD a transmission according to ISO o...

Page 21: ...ad tab displays the current bus load its time history and statistical information of the connected CAN channel 5 3 4 Error Generator Tab 5 CAN Monitor PCAN View PCAN PCI Express User Manual 4 0 0 2022...

Page 22: ...d as an error by the connected CAN nodes Note The Error Generator should only be used by experienced users and in the development environment For further information please contact our customer suppor...

Page 23: ...Frames 1 Enter the CAN ID of the CAN frame that is intended to be destroyed multiple times The following specifications refer to this ID 2 Enter the Bit Position where in the CAN frame the error is to...

Page 24: ...this is a DLL Dynamic Link Library and in Linux operating systems an SO Dynamic Shared Object PCAN Basic is designed to be cross operating system compatible Software projects can be ported between sup...

Page 25: ...el at the same time Single DLL Win SO Linux for all supported hardware types Use of up to 16 channels for each hardware type Simple switching between channels Access to the CAN channels of a PCAN Gate...

Page 26: ...CAN_Read and CAN_Write as well as CAN_ReadFD and CAN_WriteFD are available depending on the initialization mode Additional settings can be made such as setting up message filters to confine to specif...

Page 27: ...very Internal termination none Power supply Max current consumption at 3 3 V pin without power supply for external devices Single Channel 265 mA Double Channel 265 mA Quad Channel 300 mA Max current c...

Page 28: ...3 EU DIN EN IEC 63000 2019 05 VDE 0042 12 2019 05 EMC EU Directive 2014 30 EU DIN EN 55024 2016 05 VDE 0878 24 2016 05 DIN EN 55032 2016 02 VDE 0878 32 2016 02 7 Technical Specifications PCAN PCI Expr...

Page 29: ...Appendix A CE Certificate Appendix A CE Certificate PCAN PCI Express User Manual 4 0 0 2022 PEAK System Technik GmbH 29...

Page 30: ...Appendix B Dimension Drawing PCAN PCI Express Quad Channel Appendix B Dimension Drawing PCAN PCI Express User Manual 4 0 0 2022 PEAK System Technik GmbH 30...

Page 31: ...Type Peak Settings and press Enter The window PEAK settings appears The connected CAN interface is displayed under CAN Hardware Getting Started under Windows Run the CAN monitor PCAN View from the Wi...

Page 32: ...PCIe PCAN PCI 104 Express 3 7 PCAN USB FD PCAN USB Pro FD 4 0 PCAN Chip USB 4 11 PCAN PCI Express FD 4 12 PCAN PCI 104 Express FD PCAN miniPCIe FD PCAN Chip PCIe FD 4 12 PCAN M 2 PCAN Chip PCIe 4 3 PC...