F. Install columns
Lay down two columns on the installation site paralleled, position the power side
column according to the actual installation site. Usually, it is suggested to install
power side column on the front-right side from which vehicles are driven to the lift.
This lift is designed with 2-section columns. Adjustable height according to the
ceiling height and connecting the inner and extension columns.
For 211SAC installation: When the ceiling height is over 4450mm, use high setting.
When the ceiling height is between 4000-4450mm ,use low setting. It is not
allowable to install when the ceiling height is less than 4000mm.
1, High setting installation, the lower hole of extension column is connected with
inner column, see Fig.18
2, Low setting installation, the upper hole of extension column is connected with
inner column, see Fig.19