Step 3. Operate garage door by hand. 
 

                                                                 Once the manual release rod is removed completely, you will 
                                                                 be able to lift or close the garage door manually by hand. 
                                                                 When operating the garage door manually at anytime or in  
                                                                 any location through the fully open to fully closed locations,  
                                                                 check the surrounding areas each side, behind and in front 
                                                                 of the garage door to ensure no obstructions may foul the 
                                                                 door operation. 
                                                                 All counterweight garage doors are inherently heavy, it is 
                                                                 advised that when using any garage door by hand the 
                                                                 operator should remain diligent when operating the door to 
                                                                 ensure it does not open or close unexpected. 
 
 
 
 
 
 
 
 
 

 
Step 4. Reconnection of the automatic operator. 
 

                                                         To reconnect the automatic operator to the garage door, manually 
                                                         operate the garage door by hand until the automatic operator 
                                                         carriage lines-up with the steel ramp rails. 
                                                         Once in-line, re-insert the manual release rod into the automatic 
                                                         operator point by turning the release rod clockwise. 
                                                         Continue to turn the release rod clockwise until the steel bearing 
                                                         on the release rod is located between the steel ramp plates. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

PDS Garage Doors & Gates 

38 Yale Drive 

Epping (Vic) 3076 

Phone: (03) 9408 3418 

Email: [email protected] 

Web: www.pdsgaragedoors.com.au 

 

Summary of Contents for CW-509

Page 1: ...erating Manual Counterweight Garage Door Automatic Operator Model CW 509 PDS Garage Doors Gates 38 Yale Drive Epping Vic 3076 Phone 03 9408 3418 Email service pdsgaragedoors com au Web www pdsgaragedoors com au ...

Page 2: ...h the transmitter within 20 seconds then it will return to standby mode automatically 2 Travel limit setting opening closing force self learning Press and hold on SET button for 3 seconds until the LED flashes 1 Press SET button again for 1 second 1 should now display as steady not flashing Then adjust the up limit by pressing UP button Fine tuning UP or DOWN button to determine the final up limit...

Page 3: ...ilable Press DOWN button the LED displays O to cancel this function Press SET button to confirm The opener returns to standby mode The default setting of photo beam is O NOTICE Close the photo beam function when you don t use photo beam sensor 5 Auto close setting Press and hold on SET button for 3 seconds until the LED flashes 1 Press UP or DOWN to increase or decrease adjust the LED to flash 4 t...

Page 4: ...p rails are located on the same side of the motor and are attached to the back of the door panel Step 2 Remove manual release rod Using the yellow ring provided turn the manual release rod anti clockwise this will unwind the manual release rod from the automatic operator drive carriage Continue to turn the manual release rod until it come free from the automatic operator drive carriage ...

Page 5: ...nd the operator should remain diligent when operating the door to ensure it does not open or close unexpected Step 4 Reconnection of the automatic operator To reconnect the automatic operator to the garage door manually operate the garage door by hand until the automatic operator carriage lines up with the steel ramp rails Once in line re insert the manual release rod into the automatic operator p...