background image

 

    Control Panel Basic Function Settings 

 
 

1. Matching the receiver and transmitter                 
 

 

                                                                   

Coding Transmitters: 

                                                                   

Press and hold on “Code” button for 1 second until the LED 

                                                                   dot is on (Fig A). Press button on transmitter once, the dot 
                                                                   will go off, press the same transmitter button again and the 
                                                                   dot will flash fast for 8 times and then return to standby 
                                                                   mode. The transmitter is now coded into the receiver. 
                                                                   Repeat the above steps to code more transmitters. 
                                                                   The receiver has the capacity to store 20 transmitters. 
                                                                   

If the LED display flashes “F” and returns to standby mode 

                                                                   

(after you have pressed the “CODE” button), this indicates 

                                                                   that the memory storage is full (20 transmitters). 
Fig A.                                                          Follow the steps below to delete all transmitters that are 
(The opener is supplied with                      stored in the receiver memory. 
pre-coded transmitters.)                             

Press and hold on “CODE” button for more than 8 seconds 

                                                                   until the LED 

flashes “C”, all the stored codes are deleted. 

                                                                   Only the matched switch on the transmitter is available. 
                                                                   If failed to match the transmitter within 20 seconds, then 
                                                                   it will return to standby mode automatically. 
 
 
 
 

2. Travel limit setting opening & closing force self-learning 
 

                                                                  

Press and hold on “SET” button for 3 seconds until the LED 

                                                                  

flashes “1”. Press “SET” button again for 1 second “1” 

                                                                  should now display as steady (not flashing) 
                                                                  

Then adjust the up limit by pressing “UP” button. 

                                                                  F

ine tuning “UP” or “DOWN” button to determine the final up 

                                                                  l

imit position (the LED flashes “n” or “u” during opening or 

                                                                  

closing), then press “SET” button the display turn into “2” 

                                                                  automatically. 
                                                                  Adjust the down 

limit by pressing “DOWN” button. 

                                                                  

Fine tuning “UP” or “DOWN” button to determine the final 

                                                                  down limit position (the LED flash

es “n” or “u” during 

                                                                  opening 

or closing), then press “SET” button. 

                                                                  When press button to operate the opener, if the opener  
                                                                  

stops after operate a little and LED flashes “H” or “C” this 

                                                                  

indicates there’s no hall signal or the opener is overload. 

                                                                  The opener will operate a cycle automatically to remember 
                                                                  the limit positions and the original opening & closing force 
                                                                  then return to standby mode. 
                                                                  

During learning, if the door stops unusually and flashes “H”, 

                                                                  

“C”, “O”, “L” for 5 seconds this indicates there’s no hall 

                                                                  signal overload, overtime, wrong limit setting. 
 

 
 

Summary of Contents for CW-509

Page 1: ...erating Manual Counterweight Garage Door Automatic Operator Model CW 509 PDS Garage Doors Gates 38 Yale Drive Epping Vic 3076 Phone 03 9408 3418 Email service pdsgaragedoors com au Web www pdsgaragedoors com au ...

Page 2: ...h the transmitter within 20 seconds then it will return to standby mode automatically 2 Travel limit setting opening closing force self learning Press and hold on SET button for 3 seconds until the LED flashes 1 Press SET button again for 1 second 1 should now display as steady not flashing Then adjust the up limit by pressing UP button Fine tuning UP or DOWN button to determine the final up limit...

Page 3: ...ilable Press DOWN button the LED displays O to cancel this function Press SET button to confirm The opener returns to standby mode The default setting of photo beam is O NOTICE Close the photo beam function when you don t use photo beam sensor 5 Auto close setting Press and hold on SET button for 3 seconds until the LED flashes 1 Press UP or DOWN to increase or decrease adjust the LED to flash 4 t...

Page 4: ...p rails are located on the same side of the motor and are attached to the back of the door panel Step 2 Remove manual release rod Using the yellow ring provided turn the manual release rod anti clockwise this will unwind the manual release rod from the automatic operator drive carriage Continue to turn the manual release rod until it come free from the automatic operator drive carriage ...

Page 5: ...nd the operator should remain diligent when operating the door to ensure it does not open or close unexpected Step 4 Reconnection of the automatic operator To reconnect the automatic operator to the garage door manually operate the garage door by hand until the automatic operator carriage lines up with the steel ramp rails Once in line re insert the manual release rod into the automatic operator p...