Control Panel Basic Function Settings
1. Matching the receiver and transmitter
Coding Transmitters:
Press and hold on “Code” button for 1 second until the LED
dot is on (Fig A). Press button on transmitter once, the dot
will go off, press the same transmitter button again and the
dot will flash fast for 8 times and then return to standby
mode. The transmitter is now coded into the receiver.
Repeat the above steps to code more transmitters.
The receiver has the capacity to store 20 transmitters.
If the LED display flashes “F” and returns to standby mode
(after you have pressed the “CODE” button), this indicates
that the memory storage is full (20 transmitters).
Fig A. Follow the steps below to delete all transmitters that are
(The opener is supplied with stored in the receiver memory.
pre-coded transmitters.)
Press and hold on “CODE” button for more than 8 seconds
until the LED
flashes “C”, all the stored codes are deleted.
Only the matched switch on the transmitter is available.
If failed to match the transmitter within 20 seconds, then
it will return to standby mode automatically.
2. Travel limit setting opening & closing force self-learning
Press and hold on “SET” button for 3 seconds until the LED
flashes “1”. Press “SET” button again for 1 second “1”
should now display as steady (not flashing)
Then adjust the up limit by pressing “UP” button.
F
ine tuning “UP” or “DOWN” button to determine the final up
l
imit position (the LED flashes “n” or “u” during opening or
closing), then press “SET” button the display turn into “2”
automatically.
Adjust the down
limit by pressing “DOWN” button.
Fine tuning “UP” or “DOWN” button to determine the final
down limit position (the LED flash
es “n” or “u” during
opening
or closing), then press “SET” button.
When press button to operate the opener, if the opener
stops after operate a little and LED flashes “H” or “C” this
indicates there’s no hall signal or the opener is overload.
The opener will operate a cycle automatically to remember
the limit positions and the original opening & closing force
then return to standby mode.
During learning, if the door stops unusually and flashes “H”,
“C”, “O”, “L” for 5 seconds this indicates there’s no hall
signal overload, overtime, wrong limit setting.