3. Safety reverse force adjustment. 
 

                                                                 

Press and hold “SET” button for 3 seconds until the LED 

                                                                 flashes 

“1” Press “UP” or “DOWN” button until LED flashes 

                                                                 

“2” then press “SET” button.  

                                                                 

It’s now under force adjustment mode. The LED 

                                                                 displays the current set force. 
                                                                 

Press “UP” button to increase the force and “DOWN” button 

                                                                 to decrease the force. The maximum force is 9 and the 
                                                                 minimum is 1 
                                                                 

Press “SET” button to confirm, the opener returns to standby 

                                                                 mode. 
                                                                 The default setting of safety force is 5. 
 
 
 
 
 

4. Photo beam setting 
 

                                                                 

Press and hold on “SET” button for 3 seconds until the  

                                                                 

LED flashes “1” Press “UP” or “DOWN” button until the  

                                                                 

LED flashes “3”, press “SET” button, it’s now under 

                                                                 photo beam setting mode. The LED displays the current 
                                                                 setting. 
                                                                 

Press “UP” button, the LED displays “1”, the photo 

                                                                 beam function is available. Pres

s “DOWN” button the 

                                                                 

LED displays “O” to cancel this function. Press “SET” 

                                                                 button to confirm. The opener returns to standby mode. 
                                                                 

The default setting of photo beam is “O”. 

                                                                 

NOTICE: Close the photo beam function when you don’t 

                                                                 use photo beam sensor. 

 
 
 
 
 

5. Auto-close setting. 
 

                                                                 

Press and hold on “SET” button for 3 seconds until the LED 

                                                                 

flashes “1”. 

                                                                 

Press “UP” or “DOWN” to increase or decrease, adjust the 

                                                                 

LED to flash “4”, then press “SET” button to enter into 

                                                                 auto-close setting. The LED displays the current setting. 
                                                                 Pre

ss “UP” or “DOWN” button to adjust the auto-close time 

                                                                 

press “UP” button once, the auto-close time will increase 

                                                                 1 minute, the maximum time is 9 minutes. 
                                                                 

Press “DOWN” button once, the auto-close time 

                                                                 decrease 1 minute. The auto-close function will be turned 
                                                                 

off when the LED display “O”. Press “SET” to confirm, the 

                                                                 opener returns to standby mode. 
                                                                 The auto-close function can only be available when the 
                                                                 door is fully open and the photo cell beam function is on. 
                                                                 

The default setting is “O” 

 

Summary of Contents for CW-509

Page 1: ...erating Manual Counterweight Garage Door Automatic Operator Model CW 509 PDS Garage Doors Gates 38 Yale Drive Epping Vic 3076 Phone 03 9408 3418 Email service pdsgaragedoors com au Web www pdsgaragedoors com au ...

Page 2: ...h the transmitter within 20 seconds then it will return to standby mode automatically 2 Travel limit setting opening closing force self learning Press and hold on SET button for 3 seconds until the LED flashes 1 Press SET button again for 1 second 1 should now display as steady not flashing Then adjust the up limit by pressing UP button Fine tuning UP or DOWN button to determine the final up limit...

Page 3: ...ilable Press DOWN button the LED displays O to cancel this function Press SET button to confirm The opener returns to standby mode The default setting of photo beam is O NOTICE Close the photo beam function when you don t use photo beam sensor 5 Auto close setting Press and hold on SET button for 3 seconds until the LED flashes 1 Press UP or DOWN to increase or decrease adjust the LED to flash 4 t...

Page 4: ...p rails are located on the same side of the motor and are attached to the back of the door panel Step 2 Remove manual release rod Using the yellow ring provided turn the manual release rod anti clockwise this will unwind the manual release rod from the automatic operator drive carriage Continue to turn the manual release rod until it come free from the automatic operator drive carriage ...

Page 5: ...nd the operator should remain diligent when operating the door to ensure it does not open or close unexpected Step 4 Reconnection of the automatic operator To reconnect the automatic operator to the garage door manually operate the garage door by hand until the automatic operator carriage lines up with the steel ramp rails Once in line re insert the manual release rod into the automatic operator p...

Reviews: