17
OPERATION GUIDE
4.4. Grounding
The Access Point must be grounded before applying power. The following
grounding instructions must be followed. See local electrical codes for any
additional installation requirements.
Using a 6 AWG copper wire, strip back insulation and connect to the supplied wire
ground lug [Panduit LCD6-10A-L]. Attach the ground lug to the AP ground pad
using the supplied silicone grease and two screws [#10-32 x 3/8-inch]. Different
ground lugs (not supplied) can be used to provide 90° and 45° angle options
if needed.
Connect the ground wire to a suitable metal grounding rod. Securely connect the
ground wire to provide proper grounding protection. Once the Access Point ground
connection is completed, power can then be applied safely.
Grounding Lug attachment
[opposite cables]
Grounding Lug attachment
[perpendicular]
Grounding Lug attachment
[in-line with cables]
Figure 7.
Grounding Lug attachment options*
Building wall
6AWG grounding wire
Ground rod
* This representation of the PCTEL AP-WiFi-1200 enclosure shows the product as currently proposed and is subject to change.