© PCE Instruments
40
Fig. 6 Hint ISO evaluation disabled
As described previously, the ISO evaluation function requires the measuring unit velocity or
displacement in conjunction w ith the parameter RMS. Otherw ise, the menu to enable this function
cannot be opened and the follow ing hint is displayed on the screen.
Fig. 7 Hint for activation of ISO evaluation
Machine groups:
Group 1:
Large machines w ith nominal pow er >300 kW;
Electrical machines w ith shaft height >315 mm
These machines generally have plain bearings and the relatively
high
rated/operating
speeds
range
from
120 𝑚𝑖𝑛
−1
to
15,000 𝑚𝑖𝑛
−1
.
Group 2:
Medium-sized machines w ith nominal pow er betw een 15 kW and
300 kW;
Electrical machines w ith shaft height 160 mm <H <315 mm.