background image

 

 

 

 

 

c

 - ON/OFF 

 - 

ESC 

d

  - Change Setting 

- Calibration 

e

 - Menu 

 - 

Confirm 

f

  - Store Data  

g

 - Increase Symbolized Number 

- Backlight Switch 

h

  - Re-read Data  

 
 

1. Switch on 

  Press

key to turn on the gauge. The gauge will consecutively display  

- Logo 
- Serial No. and software version then the gauge will enter into measuring mode and display 
- 0.0mm/0.00mm(0.00IN/0.000IN depending on the last used) 
- Velocity rate and selected probe 
- Location Lumber 
 

2. Backlight on / off 

  Press

key, the backlight is on. Press

key again, the backlight is off. 

 

3. Measurement 

  There are three ways to go into measuring mode: 
- Switch on the gauge; 

- Press power key

 escape from MENU; 

- Measurement. 
 

4. Calibration 

When initially switch on the gauge or get an error value instead of 4.00mm (when velocity rate is 5920 m/s) if 
take measurement of test block attached on the gauge (which correct value should be 4.00mm) or other 

standard test block, the gauge needs to be calibrated simply by pressing 

key. The gauge will display same 

information and operate according to this information, then the gauge will automatically calibrate. 
 

5. Set-up 

Press 

 key, the gauge will display:

 

1. Measurement 
2. Velocity 

Rate 

3. Probe 

Setting 

4. Resolution 
5. 

Memory 

    

6. 

Limitation 

 

   

7. Average 

Measurement 

 

Summary of Contents for PCE-TG200

Page 1: ...9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com Material Thickness Meter ...

Page 2: ...3 Measurement 3 4 Calibration 3 5 Set up 3 a Measurement 4 b Velocity Rate 4 c Probe Setting 4 d Resolution 4 e Memory 5 f Limitation 5 g Average Measurement 5 h Print Out 5 i Default 6 6 Data print out optional 6 7 Technical data 6 8 Appendix 7 ...

Page 3: ... 3 Measurement There are three ways to go into measuring mode Switch on the gauge Press power key escape from MENU Measurement 4 Calibration When initially switch on the gauge or get an error value instead of 4 00mm when velocity rate is 5920 m s if take measurement of test block attached on the gauge which correct value should be 4 00mm or other standard test block the gauge needs to be calibrate...

Page 4: ...e the thickness as the same as the value of sample that is measured Press key again the gauge will store the velocity rate automatically c Probe Setting The gauge provides three types of probe for user Press key into Probe selecting state Press or to select probe 1 normal probe PT 08 2 small diameter probe PT 06 3 low frequency probe ZT 12 4 High Temperature probe GT 13 Press key to enter confirm ...

Page 5: ...on state Press or to select desired low limitation and high limitation Press key to enter confirm When the measuring value is lower or higher than the limit value a sign L or H will appear on the right top of LCD g Average Measurement You can get mean values by 2 to 9 times on TG 200 thickness gauge Press key into Average state Press to select desired average times 2 to 9 Press key to enter confir...

Page 6: ...ate 1000 9999 m s 0 0393 0 3936 inch μs Measuring range 0 65 250 0 mm 0 026 9 843 inches Resolution 0 1 mm 0 01 mm or 0 01 inch 0 001 inch Tolerance 0 65 9 99 mm 0 04 mm 10 99 99 mm 0 1 0 04 mm 100 250 mm 0 3 Power supply two 1 5V AAA dry cells Size 61 108 28 mm w h d Weight 150g with batteries Operating temperature 10 ºC to 50 ºC Storage temperature 20 ºC to 60 ºC Probe types and measuring rang S...

Page 7: ...0 207 0 241 Lucite 2680 0 105 Nickel 6040 0 237 Nylon 2730 0 103 Polyethylene 1950 0 070 Polystyrene 2350 0 092 Steel 5920 0 233 Stainless Steel 5740 0 226 Titanium 5990 0 237 Water 1490 0 059 Zinc 4210 0 165 NOTE This instrument doesn t have ATEX protection so it should not be used in potentially explosive atmospheres powder flammable gases ...