PCE Instruments PCE-TG200 Instruction Manual Download Page 7

 
 
 
 
 

8. Appendix 

Velocity rate of various materials 
 

 

 
Material   V 

(m/s) 

  V 

(in/us) 

 

  Aluminium 

  6400 

  0.252 

  Brass 

   4700 

  0.185 

  Copper 

   5010 

  0.197 

  Glass 

   5260-6120 

 0.207-0.241 

  Lucite 

   2680 

  0.105 

  Nickel 

   6040 

  0.237 

  Nylon 

   2730 

  0.103 

  Polyethylene 

  1950 

  0.070 

  Polystyrene 

  2350 

  0.092 

  

Steel 

   5920 

  0.233 

  Stainless 

Steel 

  5740 

  0.226 

  Titanium   5990 

  0.237 

  Water 

   1490 

  0.059 

  Zinc 

   4210 

  0.165

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

NOTE:

 "This instrument doesn’t have ATEX protection, so it should not be used in potentially explosive 

atmospheres (powder, flammable gases)." 

             

Summary of Contents for PCE-TG200

Page 1: ...9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com Material Thickness Meter ...

Page 2: ...3 Measurement 3 4 Calibration 3 5 Set up 3 a Measurement 4 b Velocity Rate 4 c Probe Setting 4 d Resolution 4 e Memory 5 f Limitation 5 g Average Measurement 5 h Print Out 5 i Default 6 6 Data print out optional 6 7 Technical data 6 8 Appendix 7 ...

Page 3: ... 3 Measurement There are three ways to go into measuring mode Switch on the gauge Press power key escape from MENU Measurement 4 Calibration When initially switch on the gauge or get an error value instead of 4 00mm when velocity rate is 5920 m s if take measurement of test block attached on the gauge which correct value should be 4 00mm or other standard test block the gauge needs to be calibrate...

Page 4: ...e the thickness as the same as the value of sample that is measured Press key again the gauge will store the velocity rate automatically c Probe Setting The gauge provides three types of probe for user Press key into Probe selecting state Press or to select probe 1 normal probe PT 08 2 small diameter probe PT 06 3 low frequency probe ZT 12 4 High Temperature probe GT 13 Press key to enter confirm ...

Page 5: ...on state Press or to select desired low limitation and high limitation Press key to enter confirm When the measuring value is lower or higher than the limit value a sign L or H will appear on the right top of LCD g Average Measurement You can get mean values by 2 to 9 times on TG 200 thickness gauge Press key into Average state Press to select desired average times 2 to 9 Press key to enter confir...

Page 6: ...ate 1000 9999 m s 0 0393 0 3936 inch μs Measuring range 0 65 250 0 mm 0 026 9 843 inches Resolution 0 1 mm 0 01 mm or 0 01 inch 0 001 inch Tolerance 0 65 9 99 mm 0 04 mm 10 99 99 mm 0 1 0 04 mm 100 250 mm 0 3 Power supply two 1 5V AAA dry cells Size 61 108 28 mm w h d Weight 150g with batteries Operating temperature 10 ºC to 50 ºC Storage temperature 20 ºC to 60 ºC Probe types and measuring rang S...

Page 7: ...0 207 0 241 Lucite 2680 0 105 Nickel 6040 0 237 Nylon 2730 0 103 Polyethylene 1950 0 070 Polystyrene 2350 0 092 Steel 5920 0 233 Stainless Steel 5740 0 226 Titanium 5990 0 237 Water 1490 0 059 Zinc 4210 0 165 NOTE This instrument doesn t have ATEX protection so it should not be used in potentially explosive atmospheres powder flammable gases ...

Reviews: