5.7 

Freezing measured value (HOLD) 

To freeze the displayed reading, press the Hold key. 

“HOLD" appears on the display. To resume 

the measurement, press the Hold key again. 

5.8 

Highest and lowest measured value (REC) 

Press the REC key. 

“REC" is displayed on the screen. To view the highest and lowest readings, 

press the REC key repeatedly. Press and hold the REC key to disable this function.  
As soon as this function has been switched off, the values are reset.

 

Settings 

6.1 

Automatic power-off  

To enable or disable the automatic power off function, press and hold the function key for at least 
5 seconds. The arrow keys can now be used to enable or disable automatic power off. Press the 
REC key to accept the setting. Use the on/off key to return to measurement mode.  

Note: 

The

 

"HOLD" and "REC" functions must be switched off. 

6.2 

Changing the temperature unit 

Press and hold the function key for about 5 seconds. Then press the function key again to change 
the temperature unit. The temperature unit can now be changed with the arrow keys. Press the 
REC key to accept the setting. Press the ON/OFF key to return to measurement mode. 

 
Note:

 

The "HOLD" and "REC" functions must be switched off. 
When the function is switched off, the values are reset.  

Replacing the batteries 

To insert or replace the batteries, first switch off the meter. Then open the battery compartment 
and replace the batteries. Ensure correct polarity of the batteries. Use four 1.5 V AA batteries.  
 

 

Summary of Contents for PCE-T 240

Page 1: ...ometer PCE T 240 User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last chang...

Page 2: ...ution measurement 5 5 4 Contacting speed measurement 5 5 5 Temperature measurement with a thermocouple 5 5 6 Temperature measurement with a PT 1000 temperature sensor 5 5 7 Freezing measured value HOL...

Page 3: ...ure Do not expose the device to shocks or strong vibrations The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any...

Page 4: ...000 ft min Accuracy 0 5 of rdg 1 digit Measurement range 2 0 78736 2 inch min Resolution 0 1 inch min 1 000 inch min 1 inch min 1 000 inch min Accuracy 0 5 of rdg 1 digit Stroboscope Measurement range...

Page 5: ...wer off after 10 minutes of inactivity Interface RS232 Environmental conditions 0 50 C 32 122 F 80 RH non condensing magnetic field 3 V M 30 MHz Dimensions 207 x 67 x 39 mm 8 15 x 2 63 x 15 3 in Weigh...

Page 6: ...ing tip outer cone 8 Surface speed adaptor 9 Hollow measuring tip inner cone 10 RS232 interface 11 PT1000 temperature sensor connection 12 Thermocouple connection K type 13 Photo tripod connection 14...

Page 7: ...eflective tape onto the test object Now switch on the test object and direct the light cone so that it shines on the reflective tape The speed of rotation is measured Next to the measured value an ind...

Page 8: ...n now be used to enable or disable automatic power off Press the REC key to accept the setting Use the on off key to return to measurement mode Note The HOLD and REC functions must be switched off 6 2...

Page 9: ...git stream which can be used for your specific applications An RS232 guide with the following connection is required to connect the meter to a serial PC output The 16 digit streams are displayed as fo...

Page 10: ...es Due to the contained pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012...

Page 11: ...esciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul United Kingdom SO31 4RF Italia T rkiye Tel...

Reviews: