Making a measurement 

First switch on the meter by pressing and holding the on/off key. To switch off the meter, you must 
also keep this key pressed. As soon as the meter is switched on, the measurement starts directly 
with the last measurement function used.  
To select between the individual measuring functions, press the function key repeatedly.  
 
The following functions are available: 

Display when switching 

Function 

Scope 

Stroboscope 

type 

Temperature measurement with K-type 
thermocouple  

Pt 

Temperature measurement with a PT 1000 
temperature sensor 

Photo 

Optical speed measurement  

touch 

Contact speed and velocity measurement 

5.1 

Stroboscope 

To  make  a  measurement  with  the  stroboscope  function,  select  the  "Scope"  function.  Align  the 
LEDs in the direction of the test object. Now set the speed using the arrow keys. To double or 
halve the rotation speed, hold down the double button and then use the arrow keys.  

5.2 

Optical speed measurement 

To make an optical speed measurement, select the "Photo" function. Stick a 1 x 1 cm piece of 
reflective tape onto the test object. Now switch on the test object and direct the light cone so that 
it shines on the reflective tape. The speed of rotation is measured. Next to the measured value, 
an indicator flashes once briefly as soon as the reflective tape has been recognised. 

5.3 

Contact revolution measurement 

To make a contact revolution measurement, select the "touch" function. Plug the desired adaptor 
onto the meter. Select the unit "RPM" with the UNIT key. Now carry out the measurement on the 
test object. 
 

Note: 

The wheel attachment is only intended for speed measurement. 

5.4 

Contacting speed measurement 

To make a contact speed measurement, select the "touch" function. Place the wheel attachment 
on  the  meter. Press  the  UNIT key  repeatedly  until  the  desired  unit  is  displayed.  You can  then 
carry out the speed measurement.  

5.5 

Temperature measurement with a thermocouple 

To perform a temperature measurement, select the "type" function. Insert a K-type thermocouple 
into the meter. The measured value appears on the display. 

5.6 

Temperature measurement with a PT 1000 temperature sensor 

To carry out a temperature measurement, select the "pt" function. Insert a PT 1000 resistance 
temperature probe into the meter. The measured value is displayed directly.  

Summary of Contents for PCE-T 240

Page 1: ...ometer PCE T 240 User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last chang...

Page 2: ...ution measurement 5 5 4 Contacting speed measurement 5 5 5 Temperature measurement with a thermocouple 5 5 6 Temperature measurement with a PT 1000 temperature sensor 5 5 7 Freezing measured value HOL...

Page 3: ...ure Do not expose the device to shocks or strong vibrations The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any...

Page 4: ...000 ft min Accuracy 0 5 of rdg 1 digit Measurement range 2 0 78736 2 inch min Resolution 0 1 inch min 1 000 inch min 1 inch min 1 000 inch min Accuracy 0 5 of rdg 1 digit Stroboscope Measurement range...

Page 5: ...wer off after 10 minutes of inactivity Interface RS232 Environmental conditions 0 50 C 32 122 F 80 RH non condensing magnetic field 3 V M 30 MHz Dimensions 207 x 67 x 39 mm 8 15 x 2 63 x 15 3 in Weigh...

Page 6: ...ing tip outer cone 8 Surface speed adaptor 9 Hollow measuring tip inner cone 10 RS232 interface 11 PT1000 temperature sensor connection 12 Thermocouple connection K type 13 Photo tripod connection 14...

Page 7: ...eflective tape onto the test object Now switch on the test object and direct the light cone so that it shines on the reflective tape The speed of rotation is measured Next to the measured value an ind...

Page 8: ...n now be used to enable or disable automatic power off Press the REC key to accept the setting Use the on off key to return to measurement mode Note The HOLD and REC functions must be switched off 6 2...

Page 9: ...git stream which can be used for your specific applications An RS232 guide with the following connection is required to connect the meter to a serial PC output The 16 digit streams are displayed as fo...

Page 10: ...es Due to the contained pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012...

Page 11: ...esciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul United Kingdom SO31 4RF Italia T rkiye Tel...

Reviews: