Further specifications

 

Display 

LC display, 43 x 33 mm, 5 digits 

Memory 

highest and lowest measured value 

Power supply (mains adaptor) 

9 V DC, 100 mA 

Power supply (battery) 

4 x 1.5 V AA batteries 

Power consumption 

Ø42 mA 

Automatic power off 

after 10 minutes of inactivity 

Interface 

RS232 

Environmental conditions 

0 ... 50 °C, 32 ... 122 °F, 
<80 % RH, (non-condensing); magnetic field 
<3 V/M, <30 MHz 

Dimensions 

207 x 67 x 39 mm, 8.15 x 2.63 x 15.3 in 

Weight 

230 g, 0.5 lb (without batteries) 

Delivery scope 

1 x PCE-T 240 handheld tachometer 
1 x measuring tip (outer cone) 
1 x hollow measuring tip (inner cone) 
1 x measuring wheel 
1 x reflective tape 
1 x carrying case 
4 x 1.5 V AA battery 
1 x user manual 
 

 

Summary of Contents for PCE-T 240

Page 1: ...ometer PCE T 240 User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last chang...

Page 2: ...ution measurement 5 5 4 Contacting speed measurement 5 5 5 Temperature measurement with a thermocouple 5 5 6 Temperature measurement with a PT 1000 temperature sensor 5 5 7 Freezing measured value HOL...

Page 3: ...ure Do not expose the device to shocks or strong vibrations The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any...

Page 4: ...000 ft min Accuracy 0 5 of rdg 1 digit Measurement range 2 0 78736 2 inch min Resolution 0 1 inch min 1 000 inch min 1 inch min 1 000 inch min Accuracy 0 5 of rdg 1 digit Stroboscope Measurement range...

Page 5: ...wer off after 10 minutes of inactivity Interface RS232 Environmental conditions 0 50 C 32 122 F 80 RH non condensing magnetic field 3 V M 30 MHz Dimensions 207 x 67 x 39 mm 8 15 x 2 63 x 15 3 in Weigh...

Page 6: ...ing tip outer cone 8 Surface speed adaptor 9 Hollow measuring tip inner cone 10 RS232 interface 11 PT1000 temperature sensor connection 12 Thermocouple connection K type 13 Photo tripod connection 14...

Page 7: ...eflective tape onto the test object Now switch on the test object and direct the light cone so that it shines on the reflective tape The speed of rotation is measured Next to the measured value an ind...

Page 8: ...n now be used to enable or disable automatic power off Press the REC key to accept the setting Use the on off key to return to measurement mode Note The HOLD and REC functions must be switched off 6 2...

Page 9: ...git stream which can be used for your specific applications An RS232 guide with the following connection is required to connect the meter to a serial PC output The 16 digit streams are displayed as fo...

Page 10: ...es Due to the contained pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012...

Page 11: ...esciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul United Kingdom SO31 4RF Italia T rkiye Tel...

Reviews: