PCE Instruments PCE-MA 100 Manual Download Page 3

Manual 

 

Thank you for purchasing a moisture balance from PCE Instruments.  

1  Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The device 

may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries 

caused by non-observance of the manual are excluded from our liability and not covered by our warranty.

 

 

 

The device must only be used as describes in this instruction manual. If used otherwise, this can 

cause dangerous situations for the user and damage to the meter.

 

 

The instrument may only be used if the environmental conditions (temperature, relative humidity, 

…) are within the ranges stated in the technical specifications. Do not expose the device to 

extreme temperatures, direct sunlight, extreme humidity or moisture.

 

  The case should only be opened by qualified PCE Instruments personnel. 

  Never use the instrument when your hands are wet. 

 

You must not make any technical changes to the device.

 

 

The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, no 

abrasives or solvents.

 

 

The device must only be used with accessories from PCE Instruments or equivalent.

 

 

Before each use, inspect the case for visible damage. If any damage is visible, do not use the 

device.

 

 

Do not use the instrument in explosive atmospheres.

 

 

The limit values for the measuring variables as stated in the specifications must under no 

circumstances be exceeded.

 

 

If possible, the device should be transported horizontally, bottom down and well-cushioned. 

Remove the loose attachment parts from the measuring chamber to avoid damage. We 

recommend to use the original packaging for transport.

 

  Only use IEC power connectors with a PE (ground) contact. 

  Do not touch the halogen lamps or the cover during the measurement as this can cause severe 

burns. 

  After the measurement, let the sample cool down before touching it. 

  Never operate the device when the cover is open. 

 

This instruction manual is published by PCE Instruments without any guarantee. 

 

We expressly point to our general guarantee terms which can be found in our general terms of business. 

 

If you have any questions please contact PCE Instruments. 

 

Safety symbols 

Safety-related instructions the non-observance of which can cause damage to the device or personal 

injury carry a safety symbol. 

Symbol 

Designation / description 

 

General safety symbol 

Non-observance can cause personal injury and/or damage to the device. 

 

Warning of hot surface 

Non-observance can cause burns. 

 

 

 

 

 

 

Summary of Contents for PCE-MA 100

Page 1: ...8 Jupiter FL 33458 USA From outside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint B...

Page 2: ...ion 9 4 3 Disposable aluminium sample pan 9 4 4 Spreading of the sample 9 4 5 Glass fibre filter circle 10 4 6 Practical advice 10 5 Operation 10 5 1 Measurement 10 5 2 Drying modes 11 5 2 1 Specify h...

Page 3: ...E Instruments or equivalent Before each use inspect the case for visible damage If any damage is visible do not use the device Do not use the instrument in explosive atmospheres The limit values for t...

Page 4: ...e Measurement range moisture 0 100 Readability moisture 0 01 0 1 0 01 0 1 Memory 16 drying programmes parameters Interface RS 232 Display LCD 17 mm digit height Power supply 220 V 50 Hz or 110 V 60 Hz...

Page 5: ...tection plate 1 2 The notch in the side wall of the wind shield 2 must be placed in a way that it faces the user 3 The handle of the insertion aid 3 is placed to rest in this notch 4 Place the sample...

Page 6: ...eat up mode Standard Quick Slow Measuring stop mode constant reading user time lapse Drying temperature 40 C bis zu 199 C Drying time Duration of drying process Percentage moisture Percentage dry weig...

Page 7: ...on off Start stop measurement Tare Leave settings Open settings Switch between absolute and relative measuring result Confirm current settings go to next setting Return to weighing mode short keystro...

Page 8: ...optional PCE BP 1 printer to the scales To do so you have to set the following on the printer The printer comes with an RS 232 cable which is used for connecting both devices SUB D 9 plug for RS 232 i...

Page 9: ...the measurement You should avoid tools with heat conducting properties i e which are able to transfer heat to the sample Improper handling and preparation of the sample will falsify the end result of...

Page 10: ...ure balance saves the drying parameters last used after switching off and back on These are shown in the display Prepare the sample and place it in the drying chamber You can now start the measurement...

Page 11: ...an select one out of three heat up speeds Standard heat up mode This is the default mode which is suitable for most sample types In this heat up mode 120 C are reached after approx 4 minutes Quick hea...

Page 12: ...s 2 mg 60 s 2 mg ATTENTION In this mode it is not possible to set a measuring time Manual user stop mode In this measurement stop mode the measurement can be ended by the user To do so press the key...

Page 13: ...mperature regulation temperature fluctuations of approx 4 C can occur Mind this when selecting the temperature to make sure the sample does not scorch Otherwise the moisture reading will be falsified...

Page 14: ...n be adjusted by means of a 100 g external test weight min M1 Special care must be taken when positioning the scales as little vibration as possible and balanced by means of the level The adjustment o...

Page 15: ...appear in the display which represent the last 5 measurements which are stored in the device Select a measurement by using the arrow keys and and press the key to confirm 5 The data is now sent to th...

Page 16: ...with the EU directive 2012 19 EU we take our devices back We either re use them or give them to a recycling company which disposes of the devices in line with law If you have any questions please cont...

Page 17: ...la pr sente d claration est conforme aux normes cit es ci apr s TR Uygunluk Beyan Bu bildirime ba l r n n a a daki standartlara uygun oldu unu beyan ederiz NL Conformiteit verklaring Wij verklaren hi...

Reviews: