Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The 
device  may  only  be  used  by  qualified  personnel  and  repaired  by  PCE  Instruments  personnel. 
Damage or injuries caused by non-observance of the manual are excluded from our liability and 
not covered by our warranty. 
 

 

The device must only be used as described in this instruction manual. If used otherwise, 
this can cause dangerous situations for the user and damage to the meter. 

 

The instrument may only be used if the environmental conditions (temperature, relative 
humidity, …) are within the ranges stated in the technical specifications. Do not expose 
the device to extreme temperatures, direct sunlight, extreme humidity or moisture. 

 

Do not expose the device to shocks or strong vibrations. 

 

The case should only be opened by qualified PCE Instruments personnel. 

 

Never use the instrument when your hands are wet. 

 

You must not make any technical changes to the device. 

 

The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, 
no abrasives or solvents. 

 

The device must only be used with accessories from PCE Instruments or equivalent. 

 

Before each use, inspect the case for visible damage. If any damage is visible, do not 
use the device. 

 

Do not use the instrument in explosive atmospheres. 

 

The measurement range as stated in the specifications must not be exceeded under 
any circumstances. 

 

Non-observance of the safety notes can cause damage to the device and injuries to 
the user. 

 
We do not assume liability for printing errors or any other mistakes in this manual. 
 
We expressly point to our general guarantee terms which can be found in our general terms of 
business. 
 
If you have any questions please contact PCE Instruments. The contact details can be found at 
the end of this manual. 
 
 
 

 

Summary of Contents for PCE-HWA 30

Page 1: ...Anemometer User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 30...

Page 2: ...ting the flow unit 8 6 3 Setting the temperature unit 8 7 Volume flow measurement 8 7 1 Setting the unit of the volume flow measurement 8 7 2 Area specification for volume flow measurement 9 7 3 2 3 M...

Page 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Page 4: ...0 001 100 m min Temperature measurement C 0 45 C 0 1 C 1 0 C F 32 113 F 0 18 F 1 8 F Further specifications Probe length 270 990 mm 10 63 38 98 telescopic Interface Micro USB Data storage 960 measure...

Page 5: ...PCE Instruments 3 4 Device description...

Page 6: ...ff switch long press Numeric keypad digit 6 7 Setting the temperature unit short press Select between temperature and humidity display long press Numeric keypad digit 7 8 Setting the area for volume f...

Page 7: ...PCE Instruments 5 4 1 Display description...

Page 8: ...20 Unit 21 Indication that there is no saved data 4 2 Numeric keypad It may happen that a numerical entry has to be made for example when entering the storage interval To enter this function each key...

Page 9: ...surement To make a measurement align the flow sensor with the direction of the flow An arrow on the head of the sensor indicates the orientation in relation to the wind flow Wait for at least two seco...

Page 10: ...s km h ft min knots and mps The default setting is m s 6 3 Setting the temperature unit To set the temperature unit displayed press and release C F once You can choose between C and F The default set...

Page 11: ...ximum volume flow To do this press the ENTER key 2 3 MAX appears on the display Only 2 3 of the maximum measured value will be displayed Press the ENTER key again to exit the mode 8 Lowest highest and...

Page 12: ...owest measured value When the lowest measured value is displayed only the lowest measured value will be displayed When MIN is displayed this function is active If the function is changed the value exp...

Page 13: ...1 9999 seconds Then press the REC key once The lower display briefly shows the storage interval REC is shown above the display This signals that the measured values are being recorded To interrupt sa...

Page 14: ...download win_4 htm where you can download and install the latest software Then connect the meter to the PC and open the software with administrator rights As soon as the meter is connected to the PC t...

Page 15: ...data is saved as XLS Enter a company name author and comment Open an anemometer file File format ane and xls Save an anemometer file File format ane and xls This function is only available when readi...

Page 16: ...rted data is saved in XLS format This could look like this for example After you have selected Real Time Measure a new window opens for live measurement on the PC From here the measurement data is tra...

Page 17: ...terval sec In the next window you can set the interval in seconds Below the window you can see whether a meter is connected In addition the current window can be printed A print preview can be started...

Page 18: ...ed pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our dev...

Page 19: ...Unit 11 Southpoint Business Park Via Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul Unit...