Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The 

device may only be used by qualified personnel and repaired by PCE Instruments personnel. 

Damage or injuries caused by non-observance of the manual are excluded from our liability and 

not covered by our warranty. 

 

 

The device must only be used as described in this instruction manual. If used otherwise, 

this can cause dangerous situations for the user and damage to the meter. 

 

The instrument may only be used if the environmental conditions (temperature, relative 

humidity, …) are within the ranges stated in the technical specifications. Do not expose 

the device to extreme temperatures, direct sunlight, extreme humidity or moisture. 

 

Do not use the meter during thunderstorms. 

 

Do not expose the device to shocks or strong vibrations. Dropping it can damage the 

electronic parts or the case. 

 

The case should only be opened by qualified PCE Instruments personnel. 

 

Never use the instrument when your hands are wet. Keep the meter dry. 

 

You must not make any technical changes to the device. 

 

The  appliance  should  only  be  cleaned  with  a  damp  cloth.  Do  not  use  chemicals, 

cleaning solvents or detergents. 

 

The device must only be used with accessories from PCE Instruments or equivalent. 

 

Before each use, inspect the case for visible damage. If any damage is visible on the 

meter or its test leads, do not use the device. 

 

Do not use the meter if it operates incorrectly. Protection may be compromised. 

 

Do not operate meter while Low Battery warning is on. Replace batteries immediately. 

 

Use  only  new  batteries  of  the  recommended  size  and  type.  Remove  old  or  weak 

batteries to avoid leakage and damage to the meter. 

 

If the meter is not used for a longer period of time, remove the batteries. 

 

Do not use the instrument in explosive atmospheres or near explosive vapours, dust or 

gases. 

 

The measurement range as stated in the specifications must not be exceeded under 

any circumstances. 

 

Ensure that the test leads are fully seated in the input jacks and keep your fingers away 

from the metal probe tips when taking measurements. 

 

Before changing functions using the selector switch, always disconnect the test leads 

from the circuit under test. 

 

Use only UL listed test leads with the proper safety category rating. 

 

Comply with all applicable safety codes. Use approved personal protective equipment 

when working near live electrical circuits-particularly when there is arc-flash hazard. 

 

Use caution on live circuits. Voltages above 30 V AC RMS, 42 V AC peak, or 60 V DC 

pose a shock hazard. 

 

Verify functionality before using meter by measuring a known live voltage. 

 

Do not apply voltage or current that exceeds the meter’s maximum rated input limits. 

 

Non-observance of the safety notes can cause damage to the device and injuries to 

the user. 

 

 

 

Summary of Contents for PCE-HDM 7

Page 1: ...ster PCE HDM 7 User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change...

Page 2: ...AC DC voltage measurements 8 5 3 AC current measurements 9 5 4 DC current measurements 9 5 5 Frequency and duty cycle measurements 10 5 6 Resistance measurements 10 5 7 Diode test 11 5 8 Continuity 1...

Page 3: ...spect the case for visible damage If any damage is visible on the meter or its test leads do not use the device Do not use the meter if it operates incorrectly Protection may be compromised Do not ope...

Page 4: ...ge with respect to earth ground exceeds the maximum safety rating of the meter This symbol can appear next to another symbol or connection and indicates the user must refer to the manual for important...

Page 5: ...ear and distribution panels Lighting circuits in commercial buildings Feeder lines in industrial plants Any device or branch circuit that is close to a Cat III source The measurement category CAT rati...

Page 6: ...V AAA batteries Fuse 10 A 600 V 5 x 20 mm fast blow Operating conditions 0 40 C 32 104 F 70 RH Storage conditions 10 60 C 14 140 F 80 RH Operating altitude Max 2000 m Dimensions 147 x 68 x 50 mm Weigh...

Page 7: ...solution Accuracy of reading digits AC current 4 000 A 1 mA 2 5 3 10 00 A 10 mA Overload protection 10 A 600 V fuse AC response 50 60 Hz Function Range Resolution Accuracy of reading digits DC current...

Page 8: ...gits Duty cycle 1 0 99 9 0 1 1 2 2 Input protection 600 V AC RMS or 600 V DC Pulse width 0 1 100 mS Frequency range 5Hz 10kHz Sensitivity 8 V RMS Function Range Resolution Accuracy of reading digits T...

Page 9: ...wer Off Low battery AUTO Autoranging HOLD Display hold LOZ Low Z impedance MAX MIN Maximum Minimum Bluetooth 3 1 Delivery contents 1 x multimeter PCE HDM 7 1 x test lead 1 x storage bag 1 x K type the...

Page 10: ...ges Do not connect to circuits that exceed 300 V AC RMS or 300 V DC when the meter is set to Low Z Low Z is used to check for ghost voltage Ghost voltages are present when non powered wires are in clo...

Page 11: ...wer to the circuit 6 Read the current on the LCD 5 4 DC current measurements WARNINGS Observe all safety precautions when working on live circuits Do not measure current on circuits that exceed 600 V...

Page 12: ...lead probes to the circuit under test 5 Read the frequency or duty cycle on the LCD 5 6 Resistance measurements WARNING Never test resistance on a live circuit 1 Set the rotary function switch to the...

Page 13: ...the display Reverse voltage will indicate OL Shorted devices will indicate near 0 and an open device will indicate OL in both polarities 5 8 Continuity WARNING Never test continuity on a live circuit...

Page 14: ...minute to get a stable reading on large capacitors 5 10 Temperature measurements WARNING Do not touch the temperature probe to live circuits 1 Set the rotary function switch to the F C position 2 Pre...

Page 15: ...ill update when a lower min occurs 3 Press and hold the MAX MIN button to end MAX MIN mode and return to normal operation NOTE MAX MIN does not work with frequency duty cycle diode test continuity and...

Page 16: ...o avoid electric shock do not operate meter until the battery fuse cover is securely fastened to the meter Fuse replacement WARNING To avoid electric shock remove the test leads from the meter before...

Page 17: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Page 18: ...dustrial needs com info pce italia it www pce instruments com deutsch www pce instruments com english www pce instruments com italiano The Netherlands Chile Hong Kong PCE Brookhuis B V PCE Instruments...

Reviews: